Elevated Plasma Endothelin in Patients with Diabetes Mellitus

Elevated Plasma Endothelin in Patients with Diabetes Mellitus

Diabetologia (1990) 33:306-310 Diabetologia Springer-Verlag 1990 Elevated plasma endothelin in patients with diabetes mellitus K. Takahashi, M. A. Ghatei, H.-C. Lam, D. J. O'Halloran and S. R. Bloom Department of Medicine, Royal Postgraduate Medical School, Hammersmith Hospital, London, UK Summary. Plasma concentrations of endothelin, a vasocon- noreactive-endothelin showed three forms, one in a very big strictor peptide released from vascular endothelial cells, have molecular weight position, one intermediate and one in the been measured by radioimmunoassay in 100 patients with position of endothelin-1 itself. No material appeared in the diabetes mellitus and 19 healthy subjects. The plasma immu- positions of endothelin-2 and 3. Chromatographic analysis of noreactive-endothelin concentrations were found to be normal plasma showed only the big molecular weight peak greatly raised in the patients with diabetes (I ,880 + 120 fmol/1, while material in the endothelin-1, 2 or 3 positions was below mean + SEM) compared with the healthy subjects (540 + 50 detection. The elevation of endothelin in diabetic patients fmol/1, p < 0.005). The elevation of immunoreactive-endo- may be a marker of, and further exacerbate, their vascular dis- thelin could not be explained by secondary changes in blood ease. pressure or renal disease and did not correlate with the presence of diabetic retinopathy, duration of diabetes melli- Key words: Endothelin, radioimmunoassay, diabetes melli- tus, fasting blood glucose or serum fructosamine. Fast protein tus, fast protein liquid chromatography, endothelial cell, an- liquid chromatographic analysis of the diabetic plasma immu- giopathy. Angiopathy is a major complication in diabetes mellitus [1, Subjects and methods 2]. Endothelial cell damage is suspected to occur in diabetic patients and may be one important cause of angiopathy [3]. Subjects Endothelin-1 is a potent vasoconstrictor peptide, which is thought to be synthesized by endothelial cells. It We studied plasma immunoreactive-endothelin concentrations in was originally isolated, and its structure characterised, 100 patients with diabetes mellitus (16 with Type I (insulin-depen- from the conditioned medium of porcine aortic endothe- dent) diabetes and 84 with Type2 (non-insulin-dependent) lial cells [4]. It is now known that there are three endo- diabetes) and 19 normal subjects (11 male and 8 female, 20-65 years old) by radioimmunoassay. Informed consent was obtained from thelin genes in the human genome (endothelin-1, 2 and 3 each subject. All subjects had normal renal function (serum crea- genes) [5, 6]. tinine levels < 125 gmol/1). Blood samples were obtained from a The presence of immunoreactive-endothelin in nor- subcutaneous vein in the forearm, collected into heparinized tubes mal human plasma [7, 8] and increased plasma immunore- containing aprotinin (400 KIU/ml blood) (Bayer, FRG), centrifuged active-endothelin level in patients with uraemia [9, 10] at room temperature, and the plasma separated and stored at - 20 ~ has been described. However, there are no reports of until extracted. Fasting blood glucose was measured by a glucose oxidase the possible changes from normal of plasma immunoreac- method. Spot early morning urine samples were collected and uri- tive-endothelin levels in diabetes mellitus. nary microalbumin was measured by the Technicon RA Systems To help clarify the relationship between plasma endo- microalbumin method (ID-2478-D88). Serum fructosamine was thelin and diabetic angiopathy, we measured plasma im- measured with the Technicon RA-1000 analyser [11]. Blood pres- munoreactive-endothelin concentrations in patients with sure was estimated in the supine position and the presence of diabetes mellitus and investigated the relationship be- diabetic retinopathy was assessed by ophthalmoscopic examination by diabetic ophthalmologists. tween plasma immunoreactive-endothelin concentra- The Table 1 summarizes the clinical characteristics of 100 pa- tions and blood pressure, spot urinary microalbumin, tients with diabetes and 19 normal subjects. In 84 patients with diabetic retinopathy, duration of diabetes mellitus, fasting Type 2 diabetes, one patient had a past history of cerebral infarction, blood glucose and serum fructosamine in these patients. four patients had past histories of myocardial infarction and five pa- K. Takahashi et al.: Endothelin in diabetes mellitus 307 2000 was determined by adding synthetic endothelin-1 to plasma [5 fmol endothelin/ml plasma and 25 fmol endothelin/ml plasma yielded 72 • 14% and 102 • 20% (mean • SD, n = 7) recovery, respectively]. Antiserum to endothelin-1 was raised by injecting synthetic en- 0 1500 dothelin-1 (Nova Biochem, Nottingham UK) conjugated with bo- vine serum albumin by the diazo technique [12] into rabbits. The c antiserum was used at a final dilution of 1 : 28,000. Synthetic endo- 0 0 thelin-1 (Peptide Institute, Osaka, Japan) was used as standard and c 1000 0 for iodination with Na~25Iby the chloramine T method [13]. The iodi- nated endothelin-1 was purified by high performance liquid chroma- h" LU tography as previously described [14]. After 3 days incubation at ! 500 v//////////// 4 ~ antibody-bound and free fractions were separated by charcoal adsorption of the free fraction. E The sensitivity of this assay was 0.5 fmol/tube or 250 fmol/1 indi- vidual plasma sample at 95% confidence. The assay showed 40% 0 cross reaction with endothelin-2 and 60% with endothelin-3 (Pep- Diabetic Normal tide Institute), but no cross reaction with human atrial natriuretic patients subjects peptide, neuropeptide Y, substance R vasoactive intestinal peptide, peptide histidine methionine, glucagon, angiotensin II or ACTH. Fig 1. Mean • SEM of plasma immunoreactive-endothelin concen- Intra- and interassay coefficients of variation were 12% (n = 9) and trations in 100 patients with diabetes mellitus and t9 normal sub- 19% (n = 7), respectively. jects. IR-ET: immunoreactive endothelin Chromatography tients were having treatment for angina pectoris. No cerebral vascu- Fractionation of the immunoreactive-endothelinfrom the plasma of lar disease or coronary vascular disease was found in 16 patients with diabetic patients and normal subjects was carried out by fast protein Type 1 diabetes. liquid chromatography using a high resolution reverse phase 5/5 (Pep Rpc HR 5/5) C-18 column (Pharmacia, Uppsala, Sweden). Pooled diabetic and pooled normal plasmas (n = 3) were extracted by Sep-Pak C18 cartridges, reconstituted in water containing 0.1% Extraction procedures and radioimmunoassay (v/v) trifluoroacetic acid and centrifuged for 15 min in a microfuge. The supernatants were loaded onto the column, which was first Plasma samples were extracted by Sep-Pak C18 cartridges (Waters equilibrated with 15% (v/v) acetonitrile in water [each with 0.1% Associates, Milford Mass, USA) following Sep-Pak activation by (v/v) trifluoroacetic acid]. After injection of the samples, the column 10 ml of 100% acetonitrile, 10 ml of 100% methanol and then 10 ml was eluted with a gradient of acetonitrile from 15% to 35% (v/v) in of 4% (volume/volume (v/v)) acetic acid. Three mls of each plasma water over i h at 1 ml per min per fraction. Samples of each fraction sample was acidified with 2 ml of 4% acetic acid and loaded onto the were dried in a Savant vacuum centrifuge, reconstituted in assay cartridge, and the cartridge washed with 10 ml of 4% acetic acid. Im- buffer and assayed. munoreactive-endothelinwas eluted with 2 ml of 60% (v/v) acetoni- trile/water containing 0.026 mol/1 ammonium acetate. The eluate was dried in a Savant vacuum centrifuge, the resulting Stability of endothelin in human blood. pellet reconstituted with assay buffer [60 mmol/1 POe buffer, pH 7.4 containing 10 mmol/1 EDTA, 7 mmol/1 sodium azide and 0.3% To examine the stability of endothelin in human blood, endothelin-1 (weight/volume) bovine serum albumin] and the aliquot assayed in 2 and 3 were incubated (2 pmol/ml blood) in mixed normal blood singlet. The recovery of peptide following this extraction procedure containing aprotinin (400 KIU/ml blood) at room temperature for 0 Table 1. Clinical characteristics of 100 patients with diabetes mellitus and 19 normal subjects Type 1 Type2 Normal (insulin-dependent) (non-insulin-dependent) diabetes diabetes Number (male/female) 16 (7, 9) 84 (40, 44) 19(11,8) Age (years) 40m3 59+2 35• Fasting blood glucose [3.5-5.5 mmol/1] 9.65 • 1.33 9.77 • 0.39 4.3• Duration of diabetes (years) 15.3 • 2.2 9.5 _+ 0.8 Blood pressure (mm Hg) systolic 146• 119• 121• diastolic 82• 73• 76• Urinary microalbumin [0-30 mmol/1] 65• 58• trace Serum fructosamine [2.2-2.8 mmol/1] 3.6• 4.0• 2.4• Serum creatinine [55-125 btmol/I] 76• 90m2.4 72• No. of patients with retinopathy (%) 3(19%) 7(8.3%) 0 The data are expressed as mean • SEM. The values in [ ] show the normal range. 308 K. Takahashi et al.: Endothelin in diabetes mellitus 3 a 600 50 500 4o 40 A 2 400 -6 30 E """ ....... t 30 300 F- 20 200 cc '~ i ~'0: 10 10 100 0 ' 0 10 20 30 40 50 60 70 ~0 40 50 60 70 rain rnin 5O h d ~ ET,~ET~ 4O 4O 4O Fig.2 a-d. Fast protein liquid ~ 150 chromatography of immunoreactive- 30 30 ~ 30 r endothelin in a) a pooled normal plasma ~ 100 extract, b) a pooled diabetic plasma extract, .- 20 20 *~ c) endothelin-1 mixed in normal blood but I not incubated, d) endothelin-1 incubated ~'- ~o 10 10 in normal blood at room temperature for 24 h. IR-ET: immunoreactive endo- thelin. ET1, ET2 and ET3: the elution 20 30 40 50 60 70 ~ 10 20 30 40 50 60 70 positions of endothelin-1, 2 and 3, rain rain respectively 1, 8 and 24 h. Blood samples were then centrifuged and separated, sives showed higher plasma immunoreactive-endothelin and immunoreactive-endothelin in plasma was measured by concentrations (2,340+420 fmol/1) than those without radioimmunoassay following fast protein liquid chromatography anti-hypertensives, but this difference was not statistically after extraction by Sep-Pak C18 cartridges.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    5 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us