Date: Weights: Units: 48KC A06 Part Number: 0lbs/0kg 11/1/2017 0404-1537-00000 Submitted To: [email protected] Job: Notes: Burglar Bars - Designed To Keep Out Unwanted Intruders and/or Animals. Drop In Inserts For HVAC Supply & Return Openings, 1/2 inch Diameter Cold Rolled Steel Bars, Welded To A Maximum Bar Spacing Of Six Inch On-Center. The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 Date: Weights: Units: 48TC D12 Part Number: 0lbs/0kg 11/1/2017 0404-1597-00000 Submitted To: [email protected] Job: Notes: Burglar Bars - Designed To Keep Out Unwanted Intruders and/or Animals. Drop In Inserts For HVAC Supply & Return Openings, 1/2 inch Diameter Cold Rolled Steel Bars, Welded To A Maximum Bar Spacing Of Six Inch On-Center. The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 WEIGHT: DATE: Part Number: SUBMITTAL MicroMetl 238 lbs 10/12 0821-6925-DT SUBMITTED TO: JOB NAME: COMPANY: EQUIPMENT: DRAWN BY: NOTES: NEW CARRIER UNITS (CAR-597) 48/50DJ,HJ,LJ,TJ,TM 008-014; 48LJD,TF,LJE 008-014; 50TFF,TJQ,TFQ 008-014; 48/50GJ 008,012; 48GJD,GJE,GJF 008,012; 50LJQ,QJ 008,012; 50HJQ 008-012; 48/50HC D/E08-D/E12; 48HC A/B07; 50HC A07; 50HCQ A07,D08-D09; 48/50TC A/B/D/E08-A/B/D/E14; 50TCQ D08-D12 EXISTING UNIT (CAR-528) CARRIER: 48/50DP,48DR 012-020; 48/50HJ 015-025; 48/50TJ 016-028; 48/50TM 016-025; 50HJQ 014,016; 50PQ 012-016 BRYANT: 542E 120; 542F,550F 180; 542J 150,180; 551A,581A 155,180; 558F,580F 180,240; 559D,579D 120-180; 559E 180-240; 559F 180-300; 579E 180-216; 579F 180-300,240270,300270 R/A S/A 70.563 77.75 50.0 I.D. R/A 78.25 I.D. S/A R/A 14 S/A 78.75 71.562 Features: Fully assembled curb adaptor. Includes internal duct transitions. Internally insulated with 1” - 1.5” lb insulation. Gasketing package provided. $GDSWRUSDQVDQGVXSSRUWVSURYLGHG¿HOGLQVWDOOHG Curb Adaptor Information To verify that the curb adaptor shown on this page is the correct adaptor for you job be sure the existing curb is the same size as the dimensions provided. (The bottom dimensions of curb adaptor are larger than existing curb outside dimension.) Before new HVAC unit is set in place, inspect structural stability of existing curb and building’s roof load capability. Reinforce if required. All curb adaptors will increase the systems external static pressure and must be included when calculating unit requirements. Curb adaptors are designed to attach to an existing curb with side x side duct connections. The curb adaptor is not designed for use with FRQFHQWULFGXFWFRQ¿JXUDWLRQ No calculations are available for this product. For a calculated product, please contact factory for part number, pricing, and lead time. Please contact factory for more detailed dimensional information if required. Designs are based on standard factory dimensions, and may differ in WKH¿HOG THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL’S WRITTEN CONSENT FORM NO. 2355-6P MICROMETL CORP. - 3035 NORTH SHADELAND AVENUE, SUITE 300 - INDIANAPOLIS, IN 46226 - 1-800-662-4822 --- MICROMETL SPARKS - 905 SOUTHERN WAY - SPARKS, NV 89431 - 1-800-884-4662 Part Number: S U B M I T T A L MicroMetl Knocked-down Roofcurbs for Carrier 48/50TC A/B04-A/B07; 50TCQ A04-A07; 48/50LC,HC A04-A06; 0537 Series 48/50TF,TM,HJ,TFQ 004-007; 48/50HE 003-006; 50HCQ A04-A06 Units FORM NO. 1174-27P DATE: 1/12 SUBMITTED TO 0537 Series Roofcurb Specifications (in inches) COMPANY: MicroMetl Part No. Carrier Part No. A Weight DRAWN BY: A.L.L. JOB NAME: 0537-008A N/A 8 71 lbs EQUIPMENT: 0537-011A N/A 11 82 lbs NOTES: 0537-014A CRRFCURB001A02 14 94 lbs 0537-024A CRRFCURB002A02 24 131 lbs FEATURES * Roofcurb sides and ends are 16ga. Opening for thru the galvanized steel. (.058 min.) bottom electrical connections * Gasketing package provided. (4) insulated * Full perimeter wood nailer. deck pans 1 3/4" Alt. drain hole Blocked top NOTES: corners 1.) Adjustable pitched/adjustable height curbs and taller curbs are available, 13 7/8" 20 1/4" 2" typ. 13 5/8" 2.) Attach ductwork to roofcurb. Flanges 32 1/16" of duct rest on top of curb. Supply air 3.) Roofcurbs are marked with the Carrier Return air part number. A 1 3/4" 67 3/8" 4.) The standard MicroMetl curbs do not have service plate holes. If they are Corner Detail required, you must specify on the order. 37 3/16" 1 3/4" NOTE: If using through-the-side of the curb gas or electrical connections, you must specify service holes 1" are required. Optional service plates: 0815-0537. A CROSS SECTION OF CURB 2" THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT. MICROMETL CORP. • 3035 NORTH SHADELAND AVENUE, SUITE 300 • INDIANAPOLIS, IN. 46226 • 1-800-662-4822 ••• MICROMETL SPARKS • 202 SOUTH 18TH ST. • SPARKS, NV 89431 • 1-800-884-4662 Part Number: MicroMetl Roofcurbs for Carrier 48/50TC A/D08,A09,A/D12,D14; 50TCQ S U B M I T T A L D08-D12; 48/50HC A07,D08-D12; 50HCQ A07,D08-D09; 0597 Series 48/50TF,TM,HJ 008-014; 50TFQ 008-014; 50HJQ 008-009 Units FORM NO. 1282-20P DATE: 2/12 SUBMITTED TO 0597 Series Roofcurb Specifications (in inches) COMPANY: MicroMetl Part No. Carrier Part No. A Weight DRAWN BY: 0597-008A N/A 8 90 lbs JOB NAME: EQUIPMENT: 0597-011A N/A 11 104 lbs NOTES: 0597-014A CRRFCURB003A01 14 118 lbs 0597-018A N/A 18 142 lbs FEATURES 0597-024A CRRFCURB004A01 24 164 lbs * Roofcurb sides and ends are 16ga. Opening for thru galvanized steel. (.058 min.) the bottom electrical connections * Gasketing package provided. (4) insulated * Full perimeter wood nailer. deck pans 1 3/4" Alt. drain hole * Assembly hardware not required. Blocked top corners 15 11/16" 31 3/8" 2" typ. NOTES: 15 5/16" 1.) Adjustable Pitched / Adjustable Height Supply air 40 1/16" curbs and taller curbs are available. Contact factory. Return air A 2.) Attach ductwork to roofcurb. Flanges of 1 3/4" 78 1/4" duct rest on top of curb. 3.) Roofcurbs are marked with the Carrier 50" part number. Corner Detail 1 3/4" 4.) The standard MicroMetl curbs do not have service plate holes. If they are re- 1" quired, you must specify on the order. NOTE: If using through the side of the curb A gas or electric connectors, you must specify service holes are required. Optional service plates: 0815-0597. CROSS SECTION OF CURB 2" THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT. MICROMETL CORP. • 3035 NORTH SHADELAND AVENUE, SUITE 300 • INDIANAPOLIS, IN. 46226 • 1-800-662-4822 ••• MICROMETL SPARKS • 202 SOUTH 18TH ST. • SPARKS, NV 89431 • 1-800-884-4662.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages5 Page
-
File Size-