Boiler Manual S�)NSTALLATION S�-AINTENANCE S�3TART up S�0ARTS

Boiler Manual S�)NSTALLATION S�-AINTENANCE S�3TART up S�0ARTS

LGB Series 2 Gas–Fired Boiler Boiler Manual s)NSTALLATION s-AINTENANCE s3TART UP s0ARTS Refer to Control Supplement for additional information Read all instructions before installing Installer Leave all instructions with boiler for future reference. Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee. Owner Installation and service should be performed by qualified contractor. Part No. 550-141-186/0914 LGB3ERIES'AS &IRED"OILER"OILER-ANUAL \ Hazard The following defined terms are used throughout this manual to bring attention to the presence \ of hazards of various risk levels, or to important information concerning the life of the product. Indicates presence of hazards that will cause severe personal injury, death or substantial property damage. Indicates presence of hazards that can cause severe personal injury, death or substantial property damage. Indicates presence of hazards that will or can cause minor personal injury or property damage. Indicates special instructions on installation, operation or maintenance that are important but not related to personal injury or property damage. The boiler contains ceramic fiber and fiberglass materials. Use care when handling these materials per instructions on page 28 of this manual. Failure to comply could result in severe personal injury. When calling or writing about the boiler— Please have the boiler model number from the boiler rating label and the CP number from the boiler jacket. You may list the CP number in the space provided on the Installation and service certificate found on page 27. Read all instructions before installing. Failure to follow all instructions in proper order can cause severe personal injury, death or substantial property damage. Do not use petroleum-based cleaning or sealing compounds in boiler system. Severe damage to system components can result, causing substantial property damage. Glycol — potential fire hazard — All glycol is flammable when exposed to high temperatures. If glycol is allowed to accumulate in or around the boiler or any other potential ignition source, a fire can develop. In order to prevent potential severe personal injury, death or substantial property damage from fire and/or structural damage: s .EVERSTOREGLYCOLOFANYKINDNEARTHEBOILERORANYPOTENTIALIGNITION source. s -ONITORANDINSPECTTHESYSTEMANDBOILERREGULARLYFORLEAKAGE2EPAIR any leaks immediately to prevent possible accumulation of glycol. s .EVERUSEAUTOMOTIVEANTIFREEZEORETHYLENEGLYCOLINTHESYSTEM5SING these glycols can lead to hazardous leakage of glycol in the boiler system. 2 Part Number 550-141-186/0914 s)NSTALLATIONs3TART 5Ps-AINTENANCEs0ARTS Contents 1 Codes .......................................................................................... 4 Air openings ...............................................................................4 Venting .......................................................................................6 Foundation .................................................................................8 2 Base ...........................................................................................9 Sections ....................................................................................10 Hydrostatic pressure test ......................................................... 12 Cleanout plates ........................................................................14 Flue collector hood ..................................................................15 3 Water boilers ............................................................................16 Steam boilers ...........................................................................18 Multiple steam boilers ............................................................. 20 4 ............................................................................................... 21 5 ....................................................................................... 21 6 ...................................................................... 22 7 Water boilers ............................................................................24 Steam boilers ...........................................................................25 8 ............................................................. 26 9 ! ...................................................................... 27 10 " .................................................................................... 28 11 # .......................................................................... 32 12 ...................................................................................... 34 13 $%Oand ............................................ 35 14 # ............................................................................................. 36 ' ...............................................(See Control Supplement) ( ......................................................(See Control Supplement) Part Number 550-141-186/0914 3 LGB3ERIES'AS &IRED"OILER"OILER-ANUAL 1a Pre-installation — air openings ! )NSTALLATIONSMUSTCOMPLYWITHALLLOCALCODES LAWS REGULATIONSANDORDINANCES ALSO.ATIONAL &UEL'AS#ODE!.3):nLATESTEDITION7HENREQUIRED INSTALLATIONSMUSTCONFORMTO 3TANDARDFOR#ONTROLSAND3AFETY$EVICESFOR!UTOMATICALLY&IRED"OILERS !.3)!3-%#3$ Safe lighting and other performance criteria were met with the gas manifold and control ASSEMBLYPROVIDEDONBOILERWHENBOILERUNDERWENTTESTSSPECIlEDIN!.3):nLATEST edition. #ANADIANINSTALLATIONSMUSTCOMPLYWITH#!.#3!"OR")NSTALLATION#ODE4HE EQUIPMENTSHALLBEINSTALLEDINACCORDANCEWITHTHOSEINSTALLATIONREGULATIONSINFORCEINTHE local area where the installation is to be made. These shall be carefully followed in all cases. Authorities having jurisdiction shall be consulted before installations are made. ! Combustion air and ventilation openings must comply with Section 5.3, Air for Combustion and ) 6ENTILATION OF.ATIONAL&UEL'AS#ODE!.3):nLATESTEDITION ORAPPLICABLELOCALBUILDING CODES#ANADIANINSTALLATIONSMUSTCOMPLYWITH#!.#3!"OR")NSTALLATION#ODE Boiler installation must assure sufficient openings in building and boiler room to provide ADEQUATECOMBUSTIONAIRANDVENTILATION#ONSIDERCONSTRUCTIONTIGHTNESSOFBUILDINGWHEN deciding whether additional outside openings may be needed. Older buildings with single-pane window, minimal weather-stripping and no vapor barrier often provide enough natural infiltration and ventilation without dedicated openings. .EWCONSTRUCTIONORREMODELEDBUILDINGSAREMOSTOFTENBUILTTIGHTER7INDOWSANDDOORSARE weather-stripped, vapor barriers are used and openings in walls are caulked. As a result, such tight construction is unlikely to allow proper natural air infiltration and ventilation. Air from inside building (boiler in interior room): Air openings !DEQUATECOMBUSTIONAIRANDVENTILATIONOPENINGSMUSTBEPROVIDEDTO assure proper combustion, prevent possibility of flue gas spillage and carbon monoxide emissions, causing severe personal injury or death. * Boiler room below grade 4 Part Number 550-141-186/0914 s)NSTALLATIONs3TART 5Ps-AINTENANCEs0ARTS ! s 4IGHTLYCONSTRUCTEDBUILDINGSMUSTBEPROVIDEDWITHOPENINGSTOOUTSIDEFORCOMBUSTION ) and ventilation air. These openings must be sized to handle all fuel-burning appliances, exhaust and ventilation fans and fireplaces. s 7HENOPENINGSTOBOILERROOMARETAKENTOINTERIORSPACES PROVIDETWOPERMANENTOPEN- (continued) INGSACOMBUSTIONAIROPENINGWITHININCHESOFmOORANDAVENTILATIONOPENINGWITHIN INCHESOFCEILING%ACHOPENINGMUSTPROVIDEAMINIMUMFREEAREAOFONESQUAREINCH PER "TUHINPUTOFALLAPPLIANCESINROOMPLUSREQUIREMENTSFORANYEXHAUSTFANSIN ROOM4HEINTERIORSPACESUPPLYINGCOMBUSTIONANDVENTILATIONAIRMUSTHAVEADEQUATE infiltration from outside. Air directly from outside to boiler room: s 4IGHTLYCONSTRUCTEDBUILDINGSMUSTBEPROVIDEDWITHCOMBUSTIONAIRANDVENTILATION OPENINGSTOBOILERROOMWHICHAREADEQUATETOHANDLETHEBOILERNEEDSPLUSTHENEEDSOF all other fuel-burning appliances, fireplaces and exhaust or ventilation fans. s #OMBUSTIONANDVENTILATIONOPENINGSCONNECTINGDIRECTLYORBYDUCTINGTOOUTSIDE ORTO attic or crawl spaces that freely connect with outside, must be sized as follows: /UTSIDEWALLORVERTICALDUCTINGONESQUAREINCHPER"TUHINPUTOFALLAPPLI- ANCESINROOMPLUSREQUIREMENTSFORANYEXHAUSTFANSOROTHERAPPLIANCESINROOM (ORIZONTALDUCTINGONESQUAREINCHPER "TUHOFALLAPPLIANCESINROOMPLUS REQUIREMENTSFORANYEXHAUSTFANSOROTHERAPPLIANCESINROOM !LLDUCTINGMUSTBESAMESIZEASPERMANENTOPENINGS-INIMUMAREADIMENSIONSOF DUCTINGMUSTBENOLESSTHANSQUAREINCHES 4. Other size ducting must comply with local codes. Compensate for louver blockage when calculating combustion air and ventilation openings. See Figures 1 and 2. Refer to manufacturer’s instructions for sizing. Adjustable louvers must be locked open and combustion air damper must interlock with boiler controls to open automatically before boiler operation. + Boiler room partially or completely above grade Part Number 550-141-186/0914 5 LGB3ERIES'AS &IRED"OILER"OILER-ANUAL 1b Pre-installation — venting !, 6ENTINGMUSTBEINSTALLEDACCORDINGTO0ART 6ENTINGOF%QUIPMENT OF.ATIONAL&UEL'AS #ODE !.3):nLATESTEDITIONANDAPPLICABLEBUILDINGCODES#ANADIANINSTALLATIONSMUST COMPLYWITH#!.#3!"OR")NSTALLATION#ODE Breeching must not be connected to any portion of mechanical draft system that can operate under positive pressure. Flue gas spillage Long horizontal breechings, excessive numbers of elbows or tees, or other obstructions restricting flow of combustion gases can result in possibility of flue gas spillage and carbon monoxide emissions, causing severe personal injury or death. See Figures

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    40 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us