Pulmonary Artery Catheters State of the Controversy

Pulmonary Artery Catheters State of the Controversy

Journal of Cardiovascular Nursing Vol. 23, No. 2, pp 113Y121 x Copyright B 2008 Wolters Kluwer Health | Lippincott Williams & Wilkins Pulmonary Artery Catheters State of the Controversy Susan K. Frazier, PhD, RN; Glenda J. Skinner, MS, RN, CPHQ Since 1970, pulmonary artery catheters (PACs) have been used in clinical practice to monitor the hemodynamic status of critically ill and injured patients. This technology was introduced and commercialized without considerable testing to determine safety and efficacy. After years of common clinical use, investigators identified potential increases in mortality associated with PAC use. For the past decade, investigators have studied various patient populations to elucidate the safety and efficacy of the PAC. This article reviews the historical context of PAC use, findings from recent clinical trials intended to determine safety and efficacy, issues with reliability and validity of PAC use, and complications associated with PAC use. Data from recent clinical trials do not support routine use of PACs, and the authors suggest that PAC-guided therapy should be the focus of study in future trials. KEY WORDS: hemodynamic monitoring, pulmonary artery catheter, Swan-Ganz catheter xperts estimate that 1.5 million pulmonary artery Historical Perspective Ecatheters (PACs) are used each year in the United States to monitor the hemodynamic status of critically In 1929, the first right heart catheterization was 1 performed in Germany by Werner Forssmann, a ill and injured patients. Thirty percent of these cathe- 2 ters are placed in cardiac surgical patients, 30% in physician with an interest in the circulatory system. patients in cardiac care units and catheterization labo- This groundbreaking event was even more unusual ratories, 25% in trauma and high risk surgery patients because after animal study, Dr Forssmann became other than cardiac surgery, and 15% in medical the first human to experience a right heart catheter- intensive care patients. An ongoing controversy ization when he performed this technique on himself. about the safety of and benefit associated with the Dr Forssmann did not receive support to continue use of PACs, despite their common use, exists. A his research, but others built on his foundational majority of the recent clinical trials considered work. In the 1940s, in New York, Drs Cournand and placement of the PAC as the independent variable. Richard continued to develop the technique and used However, the PAC is intended to provide informa- the PAC to elucidate important mechanisms inherent tion to guide therapy. Thus, placement of the PAC to cardiac physiology. In 1956, Drs Forssmann, alone cannot be expected to improve patient out- Cournand, and Richard jointly accepted the Nobel B comes. This article will review the historical context Prize in Physiology or Medicine for their discoveries of this controversy, recent clinical trials intended to concerning heart catheterization and pathologic ^2 determine safety and efficacy, issues with reliability changes in the circulatory system. After this and validity of PAC use, and complications associ- international recognition, right heart catheterization ated with PAC use. became more widely used over the next decade and a half but remained restricted to the catheterization laboratory, primarily for diagnosis of intracardiac and valvular defects. 3 Susan K. Frazier, PhD, RN In 1970, Swan and colleagues published the first Associate Professor, University of Kentucky College of Nursing, reported use of a flow-directed PAC. The innovative Lexington, Kentucky. balloon at the tip of the catheter supported place- Glenda J. Skinner, MS, RN, CPHQ Director of Performance Improvement and Patient Safety, Holzer ment of the catheter in the pulmonary artery without Medical Center, Gallipolis, Ohio. the use of fluoroscopy. Bedside placement of the PAC The authors of this article have no significant ties, financial or was instantly embraced by clinicians and touted as a otherwise, to any company that might have an interest in the Breliable early objective measure of left ventricular publication of this educational activity. failureIan excellent guide to therapy.^4 The later Corresponding author Susan K. Frazier, PhD, RN, University of Kentucky College of Nursing, addition of a thermistor to the distal catheter and 523 CON Building, 760 Rose Street, Lexington, KY 40536-0232 the development of the thermodilution cardiac out- ([email protected]). put technique in 1971 by the same group5 led to 113 Copyright @ 2008 Lippincott Williams & Wilkins. Unauthorized reproduction of this article is prohibited. 114 Journal of Cardiovascular Nursing x March/April 2008 considerable commercial development and an explo- technology developed for use with critically ill popu- sion of advanced monitoring of hemodynamics at lations to ensure safety and efficacy; and (4) the use the bedside. Pulmonary artery pressure and cardiac of international collaborative efforts in this research. output measurement became routine for cardiac Although the original structure of the PAC has surgery patients in particular and ubiquitous in critical remained unchanged since its inception, these cathe- care units throughout the United States. ters evolved with the addition of lumens for measure- In 1976, after the report of more than 10,000 in- ment of venous pressure, right ventricular volumes, juries related to medical devices like the Dalkon Shield and ejection fraction and cardiac pacing. The addition intrauterine device, the Medical Device Amendment of fiber optics and the use of spectrophotometry for to the Food, Drug, and Cosmetic Act of 1938 was mixed venous oxygen saturation measurement and enacted.6 This amendment charged the Food and the integration of a thermistor coil for continuous Drug Administration with ensuring the safety and cardiac output and right ventricular volume mea- efficacy of medical devices. A grandfather clause ex- surements also increased the complexity of the origi- cluded PACs from mandatory clinical testing because nal PAC. Currently, there are a wide variety of they were assumed to provide an obvious benefit to catheters used internationally. patients, were already in wide use, and were deter- mined to be Category II devices, which were considered Recent Research Findings nonlife supporting. Thus, PAC safety and their actual Studies That Compare the Use of PAC Versus effect on outcome were not scientifically investigated. No PAC Even though complications related to PAC use were Y reported soon after the introduction of PACs,7 9 PAC Several recently published studies compared clinical safety was not clearly questioned until near the end outcomes of patients managed using a PAC to those of the 1980s and into the 1990s when the mortality managed without a PAC (Table 1). Many of these rate was reported to be greater in those patients who studies focused on the patient populations identified Y received a PAC after acute myocardial infarction.10,11 by the consensus workshop group.14 19 Mortality Y Y However, a majority of scientists and clinicians dis- and morbidity,14 17,19 22 intensive care and hospital counted these concerns. Studies that suggested PAC days,15,16,19,22 intervention use (mechanical ventila- Y use was associated with greater morbidity and mortal- tion, renal support),16,19 and medication use14 16,19 ity were criticized for poor study design, and study were the most commonly evaluated outcomes of these samples were considered biased because patients who studies. received PACs purportedly had greater severity of In one of the first studies after the Pulmonary illness, so would naturally have greater morbidity Artery Catheterization and Clinical Outcomes Work- and mortality.12 shop, Rapoport and colleagues23 analyzed retrospec- In 1996, a large-scale, multisite, case-matched tive data from 34 critical care units located at 27 sites study of critically ill medical and surgical patients to evaluate PAC use and found important variations (n = 5,735) by Connors and colleagues13 indicated in practice related to PAC use across sites. Admission that PAC use was associated with greater morbidity to a surgical unit doubled the likelihood of PAC use and mortality. Serious questions about the safety and (odds ratio [OR], 2.17), whereas care provided by an efficacy of PAC were soon expressed by both clini- intensivist reduced the likelihood of catheter use by cians and the general public. In response, the National two-thirds (OR, 0.36). White race (OR, 1.38) and Institutes of Health, National Heart, Lung and Blood private insurance coverage (OR, 1.33) were also posi- Institute, in conjunction with the Federal Drug Ad- tively associated with PAC use. These data demon- ministration, convened the Pulmonary Artery Cathe- strated that organizational characteristics, as well as terization and Clinical Outcomes Workshop in 1997.1 patient characteristics, influenced the use of PACs. This group was charged with developing recommen- Several observational studies that provided little dations to improve the utility and safety of the PAC. support for routine PAC use were published early in Four recommendations arose from a consensus pro- this decade. In a comparison of patients managed cess. These included the following: (1) standardization with a PAC to those managed without, Vieillard- of education for physicians and nurses with regular Baron and colleagues14 found that PAC use was not measurement and monitoring of knowledge to improve associated with either

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    9 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us