Thyristor Converters

Thyristor Converters

Thyristor Converters EE 442-642 6-1 Thyristor Converters • Two-quadrant conversion 6-2 Simple half-wave circuits with thyristors 6-3 Thyristor Triggering v o 180o control ˆ Vst • ICs available 6-4 Case of Pure Resistive Load 6-5 Full-Bridge Thyristor Converters – Constant DC Current 6-6 DC-Side Voltage Average DC voltage: Vd Vdo cos where Vdo 0.9Vs 6-7 AC-Side Current P Vd Id 0.9Vs Id cos RSM value of source current I s Id RMS value of fundamental current I s1 (2 2 / )Id 0.9Id RMS value of harmonic current I sh I s1 / h, h 3,5,7,... Current THD THD 100 ( 2 /8) 1 48.43% Displacement Power Factor DPF cos Power Factor PF 0.9cos 6-8 Effect of Source Inductance 2L I Commutation angle: cos( ) cos s d 2Vs 2Ls Id Average of DC-side voltage: Vd 0.9Vs cos Displacement Power Factor DPF cos( 0.5) 2 Vd Id 0.9Vs Id cos (2 / )Ls Id RMS fundamental current I s1 Vs DPF Vs cos( 0.5) 6-9 Thyristor Converter with DC Source Continuous current conduction mode Discontinuous current conduction mode 6-10 AC-Side Current Waveform (continuous conduction mode) PSpice-based simulation example: Vs = 240 V, f = 60 Hz, Ls = 1.4 mH, α = 45 deg., Ld = 9 mH, Ed = 145 V. Solution: Is = 60.1 A, Is1 = 59.7 A, DPF = 0.576, PF = 0.572, THD = 12.3% 6-11 DC Voltage versus Load Current 6-12 Inverter Mode (α > 90o) 6-13 Inverter Mode with DC Voltage Source • For a large value of Ld, id can be assumed constant (= Id), then 2 Ed Vd 0.9Vs cos LS Id 6-14 Inverter Mode: Extinction Angle 180o ( ) Importance of extinction angle in inverter mode: The extinction time interval should be greater than the thyristor turn-off time: t t q 6-15 3-Phase Thyristor Converters: Simplified Case 6-16 DC-side voltage waveforms assuming zero ac-side inductance Vd Vdo cos 3 2V cos LL 1.35VLL cos 6-17 Input Line-Current Waveform 6-18 Input line-current waveforms assuming zero ac-side inductance I s 2 / 3Id 0.816Id I s1 ( 6 / )Id 0.78Id I sh I s1 / h, h 3,5,7,... THD 100[ ( 2 / 9) 1] 31% DPF cos 3 PF cos 0.955cos 6-19 3-Phase Thyristor Converter with AC-side Inductance 2L I cos( ) cos s d 2VLL 3L I V 1.35V cos s d d LL DPF cos( 0.5) 6-20 Input Line-Current Harmonics 6-21 Input Line-Current Harmonics Typical Passive Filter Block (for each phase) 6-22 12-Pluse Phase Controlled Rectifier Harmonic Order: 1, 11, 13, 23, 25, … 6-23 3-Phase Thyristor Converter with Realistic Load Continuous conduction Mode Discontinuous conduction mode 6-24 3-Phase Thyristor Inverter – Constant Current 6-25 Thyristor Inverter – Constant Voltage & Current 6-26 Thyristor Inverter Operation: Extinction Angle 6-27 Thyristor Converters: Voltage Notching Depth: Vn 2VLL sin Ls1 Ls Ls2 0 Area: An 2Ls Id 2Ls Id Width: 2VLL sin 6-28 Limits on Notching and Distortion In practice, the notch depth at PCC depends on Ls1 relative to Ls2. Let depth factor be defined by L s1 Ls1 Ls2 Given Ls1 , a higher value of Ls2 results in a smaller notch. 6-29 .

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    29 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us