EMF-2 / EMF-2m Multi-Function Timer 5502 Timberlea Blvd., Mississauga, ON L4W 2T7 Telephone: 905-366-3377 Fax: 905-366-3378 Installation Instructions Toll-Free: 1-877-226-3369 Ver. A1-001 Web: www.camdencontrols.com MADE IN CANADA PAGE 1 OF 19 Section 1__________________ General Description Wiring Wiring of this unit is dependant on the mode desired. Camden model EMF-2 (EMF-2m or EMF-2ABM) is a microprocessor controlled multi-function relay. This Select your intended application, then proceed to the section indicated. all-in-one design replaces our previous models EMF-1, EMF-1m or EMF-1ABM. Note: Do not wire Safety devices to the EMF-2. If The EMF-2 is designed for specialized applications installed, wire your safety device directly to the operator control box. such as ABM vestibules, one or two-door restrooms in shared-use facilities, 2 – 5 door airlocks, and IMPORTANT: Changes to the Mode and Out2 secure man-traps. do not take effect until a power reset. It is therefore Dip switches let you easily choose the mode, and the best to make these adjustments with the power unit automatically programs the inputs, outputs and turned off! potentiometers accordingly. NOTE: We highly recommend the use of a Removable terminal strips simplify wiring chores, and regulated power supply when powering equipment for all adjustments are conveniently located on one end barrier-free washroom applications where the strike power may be maintained from a few minutes to of the case. many hours. We offer a low-cost board-only IMPORTANT: Do not apply power to the unit until regulated power supply - CX-PS13 V2, which in turn you have read the instructions fully and made the can be powered from a small 24VAC transformer, (or required adjustments. the auxiliary power on the door control) and will Section 2__________________ supply clean, filtered & regulated 24VDC power for the strike and EMF-2. Installation Mounting APPLICATIONS & SET-UP INSTRUCTIONS: The EMF-2 should be mounted in a clean dry location out of direct contact with the elements. Suitable ABM Vestibule Control locations include inside a metal box, operator header, (Mode 1) Proceed to section 3A on Page 3 or above a false ceiling. If placed on top of a header, 1 Door Unsecured Restroom ensure that unauthorized personnel cannot tamper (Mode 2) Proceed to section 3B on Page 5 with the unit. 1 Door Secured Restroom (Mode 3) Proceed to section 3C on Page 7 If used in an Airlock or Mantrap application, the relay 2 Door Unsecured Restroom may be located at either door location, or, centrally to (Mode 4) Proceed to section 3D on Page 11 all doors. You must bring wiring from all door 2 / 3 Door Airlock (w/ auto-crossing) actuators to this unit (as well as the lock, operator, (Mode 5) Proceed to section 3E on Page 13 and door contact outputs as appropriate). 2 - 5 Door Airlock The EMF-2 is also available in an attractive lockable (Mode 6) Proceed to section 3F on Page 15 2 Door Man-trap metal cabinet version (EMF-2m or EMF-2ABM), suitable for wall mounting. (Mode 7) Proceed to section 3G on Page 17 System Inspection Instructions Page 18 Technical Specifications, & Warranty Page 19 Pa Connector Terminal Label Function ge 2 1 Power Input 12/24 Volts AC/DC P1 2 Power Input Non-polarized Power 1 Ground Off / On 12V 5V 2 Blue (or Brown) 1 LED Output ON Card-Reader Mode 2 3 N/C (or Yellow) Input 3 Relay On Indicators P2 4 CR Power +5V 4 (aka - Digital Rel 5 5 Orange (output 1) Connector) 5 1 2345 6 Output 2 6 7 Ground 2 Opt 7 1 Dry 1 Input 8 Timer Settings Non-powered Input 1 2 Dry 1 Input 1 NC 14 3 Dry 2 Input 7 Non-powered Input 2 2 C Relay 1 13 4 Dry 2 Input 3 NO 12 5 Dry 3 Input 6 Non-powered Input 3 4 NC 11 6 Dry 3 Input 5 C Relay 2 10 ) m 7 Dry 4 Input mm) 5 P3 Non-powered Input 4 6 NO 9 8 Dry 4 Input 7 NC 8 73 m 160 4 Inputs 1 9 Dry 5 Input ( 8 C Relay 3 7 P3 ( Non-powered Input 5 P4 10 Dry 5 Input 9 NO 8" 6 / /16" 3 11 Dry 6 Input 10 NC 5 Non-powered Input 6 6 7 12 Dry 6 Input 6 13 11 C Relay 4 4 13 Dry 7 Input 2 Non-powered Input 7 12 NO 3 14 Dry 7 Input 13 NC EMF-2 2 1 1 Relay 1 – NC 14 C Relay 5 1 2 Relay 1 – COM Form C 15 NO 3 Relay 1 – NO Trouble 7 4 Relay 2 – NC Output 6 Digital 5 Relay 2 – COM Form C 1 12/24V 5 In/Out P1 Power 4 6 Relay 2 – NO 2 terminal P2 7 Relay 3 – NC strip 3 P4 8 Relay 3 – COM Form C Input 2 disables 9 Relay 3 – NO Door #2 1 1" (25 mm) 10 Relay 4 – NC 11 Relay 4 – COM Form C 12 Relay 4 – NO 13 Relay 5 – NC 14 Relay 5 – COM Form C 15 Relay 5 – NO Top View 2 7/8" (72 mm) Side View NOTE: Pin 2 Connector. When connecting to Camden Card Reader in ABM Mode it is possible to read all cards by wiring the Blue wire to Pin 2, or only Cards beginning with a 4, 5, & 6 by wiring the Brown wire (Data) to Pin 2, and the yellow wire (Clock) to pin 3. 5502 Timberlea Blvd Camden Door Controls Mississauga, Ontario L4W 2T7 Dip Dip = 4 5 SCALE: NONE DRAWN BY: DGW DATE: 03/24/10 REVISED: 06/08/10 RELAY 5 CHART OFF OFF 1 To have Relay 5 shadow another ON OFF 2 relay, set dipswitch EMF-2 Diagram 1, Electrical and Mechanical as shown at right OFF ON 3 ON ON 4 DRAWING No: DRG-EMF-2_01 FILENAME: EMF-2 Diagram 1.vsd Section 3A________________ Step 3 Set-up Instructions Connections ABM Vestibule Controller (Mode 1) Refer to Diagram 2 (next page) for the following connections. The EMF-2 is a compact unit designed to interface an automatic door operator with a card reader and lock Wire all input connections to the (removable) Input system such as those used on banks. terminal strip (numbered 1 - 14). Firmly re-insert connector if removed. When in “Day Mode” the strike is retracted (manually, or electrically) and the card reader is out of the Next, make your wiring connections to the Relay circuit. Pressing either exterior or interior wall switch Output strip (numbered 1 – 15). Note: Relay 4 is not will activate the door operator. used in this application. Re-insert connector. When the EMF-2 is switched to “Night Mode” the If you are using this system with our Model #51T2B electric strike is energized (door is locked), and the card reader – then refer to the 7-pin Digital I/O strip, exterior activator (ie - wall switch) is removed from and make wiring connections as per the respective the circuit. When a valid card is inserted, the strike card-reader wiring diagram. unlocks immediately, and the exterior switch is put If using our model #ECI-210, or another type of card back into the circuit for an adjustable period, so that if reader, or dry contact - wire to terminals 1 & 2 of the pushed by the user, it will open the door Digital I/O strip. (Re-insert connector firmly if automatically. The inside switch will unlock and open removed.) the door at all times. Finally, connect 12 or 24 Volt AC or DC supply to A new feature of the EMF-2 is the ability to add an terminals 1 & 2 of the 2-pin Power Connector. “Emergency - Push-to-Lock” switch near the ATM (The terminals are not polarity sensitive). machine that when activated “locks out” the card reader input in order to afford the user extra security. Step 4 Opening the door from the inside resets the system. Adjustments (The system will also reset automatically after 10 In this application, you will use pots # 1 – 4. (Pot 5 minutes.) has no effect. Model EMF-2 ABM provides for a lockable cabinet to Timer 1 Strike Delay-on-Release house the relay, c/w two lighted push-button switches Timer 2 Operator Delay-on-activate – one to turn the relay power ON or OFF, and the Timer 3 Operator Delay-on-release other to select DAY or NITE modes. Timer 4 Exterior Switch enable time Step 1 Apply power to door operator, EMF-2, and any Select MODE 1 via the first 3 positions of the dip applicable activating devices (ie – card-reader). switch as shown below: Observe the RED Power LED on the unit. It should be lit. If not, re-confirm proper voltage connections. Off On 1 Turn key switch (Input #3) to “Night Mode”. (Night 2 mode via an open contact, Day mode via closed). 3 See Diagram 1 for location of dipswitch, connectors, Activate interior switch. Door should unlock and open. Adjust potentiometers # 1, 2 & 3 for desired & potentiometers. operating times. Step2 Dip switch Options Activate exterior switch. Door should remain closed and locked. Now activate the card reader input. The Push dipswitch #6 ON, for a continuous duty strike, door should unlock. Adjust Timer 1 for sufficient time which is to be energized during “Day Mode”. If using on the strike.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages19 Page
-
File Size-