2. Screening Techniques

2. Screening Techniques

2. SCREENING TECHNIQUES 2.1 X-ray techniques the contrast and the spatial resolution are poor, making detection of small lesions difficult. The The original technique for mammography mammogram in Fig. 2.1b, from the same era, is of was introduced by Salomon in Germany in 1913, much higher quality and illustrates a cancer seen 18 years after the discovery of X-rays by Roentgen on the basis of an irregularly shaped mass (black (Salomon, 1913). A mammogram is formed by arrow). Fig. 2.1c shows a digital mammogram, recording the two-dimensional (2D) pattern of illustrating the enormous improvement that X-rays transmitted through the volume of the has occurred in both technology and technique. breast onto an image receptor. Breast cancer is Breast positioning, penetration of the tissue, and detected radiographically on the basis of four contrast are excellent, allowing visualization of major signs: a mass density with specific shape a small area of ductal carcinoma in situ (DCIS) and border characteristics, microcalcifications, seen on the basis of microcalcifications, and, architectural distortions, and asymmetries more importantly, providing the opportunity to between the radiological appearance of the left detect an immediately adjacent high-grade inva- and right breast (Kopans, 2006). These signs sive cancer 1.7 mm in diameter. are often very subtle, and in order for them to Excellent image quality is an essential compo- be detected accurately and when the cancer is at nent but not, on its own, a sufficient component the smallest detectable size, the technical image to ensure a high level of accuracy in cancer detec- quality of the mammograms must be excellent tion. Of equal or perhaps greater importance are (Young et al., 1994; Taplin et al., 2002). At the the skill of the radiographer who conducts the same time, because ionizing radiation is carcino- examination and sets the equipment operating genic, it is desirable that the radiation dose factors and the skill, experience, and judgement received by the patient is as low as is reasonably of the radiologist who interprets the images. achievable consistent with the required image This emphasizes the need for thorough training quality (Young et al., 1997). The trade-off between and ongoing maintenance of skills of these imaging performance and radiation doses inevi- individuals. tably involves compromises, and optimization of imaging is inextricably linked to technical design 2.1.1 X-ray equipment elements in the imaging system. Fig. 2.1 shows examples of mammograms obtained during Mammography was originally carried out different periods and with different equipment. using general-purpose X-ray imaging systems. Fig. 2.1a shows a mammogram from one of the Although the principles remain the same, it was randomized controlled trials (RCTs) in the early gradually recognized that the specific imaging 1980s; the image is poorly exposed, and both requirements for effective detection of breast 113 IARC HANDBOOKS OF CANCER PREVENTION – 15 Fig. 2.1 Examples of mammograms of different quality a b c (a) Mammogram produced in the early 1980s. (b) Mammogram from the same era produced with better breast compression, exposure factors, and film processing, illustrating a tumour mass (arrow). (c) Mediolateral oblique digital screening mammogram of a woman aged 62 years, illustrating a cluster of microcalcifications near the nipple, later diagnosed as high-grade ductal carcinoma in situ (DCIS) 4 mm in diameter, and an adjacent area of invasive cancer 1.7 mm in diameter. Unpublished clinical mammograms kindly provided by (a) Dr Roberta Jong, Toronto, Canada, (b) Dr László Tabár, Falun Central Hospital, Sweden, and (c) Dr Pavel Crystal, Mount Sinai Hospital, Toronto, Canada. cancer would be better met if equipment were the X-ray source for mammography (known as adapted specifically for the purpose of mammog- the focal spot or target) is much smaller than that raphy (AAPM, 1990; NCRP, 2004). Between the used for most general radiography procedures. mid-1960s and 1990, several important tech- Modern mammography systems most frequently nical improvements were introduced, and these use a nominal focal spot size of 0.3 mm for regular resulted in a highly specialized imaging system mammography and of 0.1 mm for magnification (Feig, 1987; Haus, 1987). A major technical procedures (IAEA, 2014). change came about in 2000 when the first digital The spectrum, or distribution of X-rays of mammography systems became available. different energies in the beam, is also specialized Some of the specialized features of mammog- for mammography (Jennings et al., 1981; Beaman raphy systems are briefly described here. & Lillicrap, 1982). To maximize the contrast Very high spatial resolution is required in between soft tissues such as normal fibroglan- mammography to allow discrimination of fine dular tissue and carcinoma, it is desirable to use microcalcifications and morphological features an energy spectrum with much lower energies of soft tissue structures such as masses. To support than are used for general radiography. this resolution requirement, the effective size of 114 Breast cancer screening The X-ray spectrum is determined by three attenuation of the Mo filter increases sharply factors: the material used to form the X-ray target, just above the characteristic energies emitted by the type and thickness of metallic filter placed in the Mo target, creating a relatively transmissive the X-ray beam, and the kilovoltage applied to energy “window” that allows the characteristic the X-ray tube (IAEA, 2014). These factors affect X-rays (emitted just below the K-edge energy of both the spectral shape and the intensity of X-rays Mo) to pass through the filter and expose the in the beam that is incident upon the breast for image. The result is selective removal of both the imaging. Two other variables directly influence low-energy and high-energy X-rays, leaving a the amount of X-rays incident on the breast, but fairly narrow spectrum (Fig. 2.2) with an effec- not the contrast characteristics of the beam: the tive energy suitable for imaging the breast. tube current, typically measured in milliamperes In general radiography, it is customary to (referred to as “the mA”) and the exposure time compensate for increased body-part thick- (the time during which this current flows from ness or attenuation properties by adjusting the the cathode of the tube to the target to produce kilovoltage applied to the tube (IAEA, 2014). the exposure). However, when the spectrum is formed largely Decreasing the energy of the X-ray spectrum with characteristic X-rays, as is the case with many increases the differences in X-ray absorption mammography systems, changing the kilovoltage between different tissue types, thereby increasing has a limited effect on the energy spectrum, and contrast. However, low-energy X-rays are more this could make it difficult to adequately penetrate heavily absorbed in the breast, and therefore dense breast tissue to obtain the required image more need to be used to obtain an acceptable contrast in some parts of the breast. Inadequate number of photons reaching the imaging system. contrast could result in cancers being missed. To This results in an increased radiation dose to alter the effective energy of the beam to a greater the breast. As in any type of X-ray imaging, a degree, most modern mammography systems compromise is required between maximizing provide a second, readily interchangeable filter, contrast and controlling radiation dose. typically composed of rhodium (Rh). Together In 1967, a specialized mammography tube with a selection of increased kilovoltage, this was introduced by Gros in France (Gros, 1967). Mo–Rh combination provides a more-pene- The tube was equipped with a molybdenum (Mo) trating spectrum than is possible with the Mo– target, rather than the tungsten used in gener- Mo target–filter combination. A further increase al-purpose tubes. Mo emits characteristic X-rays in energy can be achieved by fitting the X-ray at 17.5 keV and 19.5 keV in addition to a broad- tube with dual target materials, for example er-energy bremsstrahlung spectrum (X-rays with a Rh target in addition to the standard Mo emitted when an electron suddenly slows down target. The higher energy of the characteristic when impinging on a target material). Operated X-rays from Rh provides a more-penetrating at a tube potential of 24–32 kV for imaging using beam, albeit with lower contrast. Depending on a screen-film detector, the tube provides a more the breast thickness and fibroglandular content optimal compromise between low energy (with (often referred to as breast density), target–filter high contrast and the accompanying high dose) combinations of Mo–Mo, Mo–Rh, or Rh–Rh can and a more-penetrating, high-energy spectrum today be selected and used in conjunction with that allows low-dose imaging but at the penalty a kilovoltage selection that optimizes imaging of reduced image contrast. performance. The Mo target is typically used in conjunc- tion with an external Mo beam filter. X-ray 115 IARC HANDBOOKS OF CANCER PREVENTION – 15 Fig. 2.2 Use of selected target materials and K-edge filters to define the energy spectrum for mammography 8.0E+05 ) 7.0E+05 -2 6.0E+05 5.0E+05 Unfiltered Mo filter spectrum 4.0E+05 3.0E+05 2.0E+05 Photon Fluence (mm 1.0E+05 0.0E+00 0 5 10 15 20 25 30 X-ray Energy, E /keV The filtered spectrum has been scaled upwards for clarity. Characteristic emission peaks from molybdenum (Mo) are seen at 17.5 keV and 19.5 keV. Courtesy of Dr. M. Yaffe. 2.1.2 Screen-film mammography therefore appear as areas of decreased optical density (white), whereas the fatty areas appear To achieve high spatial resolution, the first darker.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    52 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us