Power Breakers, Contactors and Fuses

Power Breakers, Contactors and Fuses

Power Breakers, Contactors and Fuses Power Breakers, Contactors 3.1 Power Circuit Breakers 3 and Fuses Family Low Voltage Power Circuit Breakers . V4-T3-2 Magnum DS Low Voltage Power Circuit Breakers . V4-T3-6 3 Magnum MDSL Current Limiting Power Circuit Breaker . V4-T3-12 Magnum SB Low Voltage Insulated Case Circuit Breakers. V4-T3-15 3 Magnum IEC Rated Air Circuit Breakers . V4-T3-23 3 Magnum DC (Direct Current) Low Voltage Switches . V4-T3-33 Series NRX Low Voltage Power Circuit Breakers with PXR . V4-T3-35 3 Series NRX Low Voltage Power Circuit Breakers with Digitrip . V4-T3-47 Medium Voltage Circuit Breakers . V4-T3-55 3 3.2 Medium Voltage Power Contactors 3 Product Overview . V4-T3-72 3 SL MV Power Contactor 7.2 kV/160–400A. V4-T3-74 SL MV Power Contactor 7.2 kV/800A . V4-T3-83 3 SL MV Power Contactor 15 kV/300A. V4-T3-87 3 3.3 Fuses General Product Overview . V4-T3-91 3 Power Fuse . V4-T3-91 Power vs. Distribution . V4-T3-91 3 Low vs. Medium vs. High Voltage. V4-T3-91 3 Expulsion vs. Current Limiting (Definitions per ANSI C47.40-1993). V4-T3-92 Fuse Types. V4-T3-92 3 General Fuse Component Terms. V4-T3-92 3 3.4 Expulsion Fuses Product Description. V4-T3-94 3 Accessories . V4-T3-94 3 Catalog Number Selection . V4-T3-95 Product Selection . V4-T3-96 3 3.5 Current Limiting Fuses 3 Catalog Number Selection . V4-T3-115 Product Selection . V4-T3-117 3 3 3 3 3 3 3 3 3 3 3 Volume 4—Circuit Protection CA08100005E—July 2017 www.eaton.com V4-T3-1 Revision notes Volume 4—Circuit Protection, CA08100005E Tab 3—Power Breakers, Contactors and Fuses Revision date Section Change page(s) Description 06/09/2017 3.1 V4-T3-1 Updates to TOC 06/09/2017 3.1 V4-T3-35– V4-T3-46 New Series NRX Low Voltage Power Circuit Breakers with PXR inserted 06/09/2017 3.1 V4-T3-47 Update to product name (Series NRX Low Voltage Power Circuit Breakers with Digitrip) 07/05/2017 All All Footer revision date changed to July to match updated print version Power Breakers, Contactors and Fuses 3.1 Power Circuit Breakers 3 Power Circuit Breaker Contents Description Page 3 Low Voltage Power Circuit Breakers Features, Benefits and Functions . V4-T3-3 3 Magnum DS Low Voltage Power Circuit Breakers . V4-T3-6 3 Magnum MDSL Current Limiting Power Circuit Breaker . V4-T3-12 3 Magnum SB Low Voltage Insulated Case Circuit Breakers . V4-T3-15 3 Magnum IEC Rated Air Circuit Breakers . V4-T3-23 Magnum DC (Direct Current) Low Voltage 3 Switches. V4-T3-33 Series NRX Low Voltage Power Circuit 3 Breakers with PXR . V4-T3-35 Series NRX Low Voltage Power Circuit 3 Breakers with Digitrip . V4-T3-47 Medium Voltage Circuit Breakers . V4-T3-55 3 3 Low Voltage Power Circuit Breakers 3 Product Overview 3 Magnum Low Voltage Power Four Product Families Circuit Breakers for Global Magnum consists of four Magnum DS Low Voltage Magnum IEC Air Circuit 3 Application product families; each Power Circuit Breakers for Breakers for IEC Rated Magnum® low voltage provides specific ratings, ANSI Rated Switchgear Switchboards power circuit breakers enable features and approvals to Applications ● 3 comprehensive solutions to optimize performance when Up to 690 Vac ● meet and exceed the unique applied in power distribution Up to 635 Vac ● 200 to 6300 A continuous 3 and wide-ranging ● 200 to 5000 A continuous ● equipment and custom 40 to 105 kA Icu/Ics requirements of today’s enclosures. ● 42 to 200 kA interrupting 3 global power distribution systems. This powerful circuit breaker offering is 3 designed for ultimate custom configuration and application 3 flexibility, with the needs of the power distribution equipment user and the Magnum DS Low Voltage Power Circuit 3 Breaker Family ANSI Rated for electrical equipment Switchgear Applications manufacturer in mind. Magnum IEC Low Voltage Air Circuit 3 Breaker Family Magnum SB Low Voltage 3 Insulated Case Circuit Magnum DC Switches for Breakers for Switchboard Direct Current Applications Applications 3 ● Up to 1000 Vdc ● Up to 635 Vac ● 800 to 3200 A continuous ● 200 to 5000 A continuous 3 ● 50 to 65 kA withstand ● 50 to 150 kA interrupting rating 3 3 3 Magnum SB Low Voltage Insulated 3 Case Circuit Breaker Family UL Rated Magnum DC Switch Family for Switchboard Applications 3 3 V4-T3-2 Volume 4—Circuit Protection CA08100005E—July 2017 www.eaton.com Power Breakers, Contactors and Fuses Power Circuit Breakers 3.1 Features, Benefits and Functions 3 ● 200 kA interruption ● Two-step stored energy ● Field-installable ratings with current mechanism for manually accessories (UL® listed) limiting performance and and electrical operated common across the 3 low current let-through to breakers breaker frames and reduce damaging energy ● Digitrip™ RMS Trip Unit designed to be easily 3 to downstream equipment family protection with installed in the field to at high fault levels four models each providing service or modify the 3 ● Withstand ratings up to increasing levels of breaker at the point of use 100 kA to maximize protection and feature ● Secondary terminal 3 system coordination and options for coordination, contacts mounted at the selectivity information and top front of the breaker and 3 ● Four physical frame sizes diagnostics: away from the primary (Narrow, Standard, Double ● Microprocessor-based voltage areas for improved Narrow and Double) rms sensing safety and access. Finger- 3 safe terminal blocks to promote breaker ● Basic to programmable application in compact overcurrent protection accommodate ring-tongue 3 modular enclosures and and alarms or spade type terminals as improve enclosure density standard ● Local display for Through-the-Door Design for Human 3 ● ● Continuous current Arcflash Reduction Interface with the Breaker information, status Compartment Door Closed ratings from 800 to and diagnostics Maintenance System 3 Eaton’s patented Arcflash 6300A with 100% rating ● Ampere, voltage and Reduction Maintenance at 104 ºF (40 ºC) and no power metering 3 derating on most ratings System technology ● up to 122 ºF (50 ºC) Power quality, provides maintenance staff harmonics and 3 ● with improved safety of Fixed breaker mounting waveform capture configurations with downstream maintenance ● horizontal and optional Communications with locations using a simple 3 vertical and front translators to common and reliable method to connected terminal protocols reduce fault clearing times 3 connections ● Zone selective and energy during an arc interlocking for flash event (radiation, ● Drawout breaker 3 improved coordination sound, pressure, mounting configurations temperature). Arcflash ● Integral Arcflash with cassette and optional Reduction Maintenance Reduction Maintenance 3 safety shutters System uses a separate System™ ● Three- and four-pole analog trip circuit, providing 3 breaker configurations ● Breaker health faster signal processing High Technology Microprocessor- ● monitoring Based Digitrip RMS 1150+ Trip Units are Through-the-door design and interruption times than Available With Advanced Features Like 3 for human interface with the standard (digital) Programmable Overcurrent Settings, the breaker compartment “instantaneous” protection. Power Metering, Power Quality and Communications door closed The Arcflash Reduction 3 ● DC rated switches for Maintenance System direct current applications function is activated either 3 directly on the circuit breaker through a local 3 switch or remotely through communications or a digital input 3 3 3 3 3 3 3 3 3 Volume 4—Circuit Protection CA08100005E—July 2017 www.eaton.com V4-T3-3 Power Breakers, Contactors and Fuses 3.1 Power Circuit Breakers 3 Breaker Features on Front Cover Magnum DS Drawout Breaker The controls and indicators 3 1 2 are functionally grouped on 3 the breaker faceplate to optimize the human 3 interface, visibility and ease of use. For maximum safety, 3 a modern, through-the-door 4 design permits access to the 3 breaker levering system, trip 5 unit, controls and indicators 6 with the door closed. 7 3 1 Red Mechanical Trip Flag 3 Pop-out Indicator (Optional)—Interlocked 8 Indicator Requiring 3 Manual Reset is also Available 9 3 2 Accessory Viewing Windows for: 3 j ● Shunt Trip Attachment 3 (STA) k ● Spring Release Device 3 (SR) l ● Undervoltage Release 3 (UVR) Device or Second STA 3 3 Digitrip RMS Trip Unit (Model 520M Shown) 3 Protected by Clear Cover 4 3 Contact Status Indicators: ● OPEN—Green 3 ● CLOSED—Red 5 Spring Status Indicators: 3 ● Charged—Yellow Accessory Viewing Windows Visibly Confirm the Breaker Shunt Trip, Spring 3 ● Discharged—White Release, and UVR Installation and Their 6 Control Voltage Rating Push OFF (Open) Drawout Breaker Levering Can be Accomplished With the Compartment 3 Pushbutton—Red Door Closed Without the Need for a 7 Special Levering Tool Push ON (Close) Through-the-Door Design for Human 3 Pushbutton—Green Interface with the Breaker 8 Compartment Door Closed, for Example, 3 Manual Spring Charging Manually Charging the Stored Handle for Manually Energy Springs Charging the Stored 3 Energy Springs 9 3 Mechanical Operations Counter (Optional) 3 j Key Off Lock (Optional) k Padlockable Levering 3 Device Shutter for 3 Drawout Breakers l Color-Coded Position 3 Indicator for Drawout Breakers: 3 ● CONNECT—Red ● TEST—Yellow 3 ● DISCONNECT—Green V4-T3-4 Volume 4—Circuit Protection CA08100005E—July 2017 www.eaton.com Power Breakers, Contactors and Fuses Power Circuit Breakers 3.1 Breaker Internal Features 6 3 1 3 Magnum is designed for ease Padlockable Levering of access for inspection, Device Shutter for modification and Drawout Breakers 3 maintenance at the point of 7 2 use. The breaker front cover Color-Coded Position 3 is easily removed with four Indicator for Drawout captive bolts, revealing the Breakers: 3 modular internal breaker ● CONNECT—Red features.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    149 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us