NFS-3030/E Operations Manual

NFS-3030/E Operations Manual

Fire Alarm Control Panel NFS-3030/E Operations Manual Document 51344 11/4/03 Rev: C PN 51344:C ECN 03-419 Technical Manuals Online! - http://www.tech-man.com Fire Alarm System Limitations While a fire alarm system may lower insurance rates, it is not a substitute for fire insurance! An automatic fire alarm system—typically made up of Heat detectors do not sense particles of combustion and smoke detectors, heat detectors, manual pull stations, audible alarm only when heat on their sensors increases at a predeter- warning devices, and a fire alarm control panel with remote mined rate or reaches a predetermined level. Rate-of-rise notification capability—can provide early warning of a develop- heat detectors may be subject to reduced sensitivity over time. ing fire. Such a system, however, does not assure protection For this reason, the rate-of-rise feature of each detector against property damage or loss of life resulting from a fire. should be tested at least once per year by a qualified fire pro- The Manufacturer recommends that smoke and/or heat detec- tection specialist. Heat detectors are designed to protect tors be located throughout a protected premise following the property, not life. recommendations of the current edition of the National Fire IMPORTANT! Smoke detectors must be installed in the Protection Association Standard 72-1999 (NFPA 72-1999), same room as the control panel and in rooms used by the sys- manufacturer's recommendations, State and local codes, and tem for the connection of alarm transmission wiring, communi- the recommendations contained in the Guide for Proper Use of cations, signaling, and/or power. If detectors are not so System Smoke Detectors, which is made available at no located, a developing fire may damage the alarm system, crip- charge to all installing dealers. A study by the Federal Emer- pling its ability to report a fire. gency Management Agency (an agency of the United States Audible warning devices such as bells may not alert people government) indicated that smoke detectors may not go off in if these devices are located on the other side of closed or as many as 35% of all fires. While fire alarm systems are partly open doors or are located on another floor of a building. designed to provide early warning against fire, they do not Any warning device may fail to alert people with a disability or guarantee warning or protection against fire. A fire alarm sys- those who have recently consumed drugs, alcohol or medica- tem may not provide timely or adequate warning, or simply tion. Please note that: may not function, for a variety of reasons: • Strobes can, under certain circumstances, cause seizures Smoke detectors may not sense fire where smoke cannot in people with conditions such as epilepsy. reach the detectors such as in chimneys, in or behind walls, on roofs, or on the other side of closed doors. Smoke detectors • Studies have shown that certain people, even when they also may not sense a fire on another level or floor of a building. hear a fire alarm signal, do not respond or comprehend the A second-floor detector, for example, may not sense a first- meaning of the signal. It is the property owner's responsi- floor or basement fire. bility to conduct fire drills and other training exercise to make people aware of fire alarm signals and instruct them Particles of combustion or “smoke” from a developing fire on the proper reaction to alarm signals. may not reach the sensing chambers of smoke detectors because: • In rare instances, the sounding of a warning device can cause temporary or permanent hearing loss. • Barriers such as closed or partially closed doors, walls, or chimneys may inhibit particle or smoke flow. A fire alarm system will not operate without any electrical power. If AC power fails, the system will operate from standby • Smoke particles may become “cold,” stratify, and not reach batteries only for a specified time and only if the batteries have the ceiling or upper walls where detectors are located. been properly maintained and replaced regularly. • Smoke particles may be blown away from detectors by air Equipment used in the system may not be technically com- outlets. patible with the control panel. It is essential to use only equip- • Smoke particles may be drawn into air returns before ment listed for service with your control panel. reaching the detector. Telephone lines needed to transmit alarm signals from a The amount of “smoke” present may be insufficient to alarm premise to a central monitoring station may be out of service smoke detectors. Smoke detectors are designed to alarm at or temporarily disabled. For added protection against tele- various levels of smoke density. If such density levels are not phone line failure, backup radio transmission systems are rec- created by a developing fire at the location of detectors, the ommended. detectors will not go into alarm. The most common cause of fire alarm malfunction is inade- Smoke detectors, even when working properly, have sensing quate maintenance. To keep the entire fire alarm system in limitations. Detectors that have photoelectronic sensing excellent working order, ongoing maintenance is required per chambers tend to detect smoldering fires better than flaming the manufacturer's recommendations, and UL and NFPA stan- fires, which have little visible smoke. Detectors that have ion- dards. At a minimum, the requirements of Chapter 7 of NFPA izing-type sensing chambers tend to detect fast-flaming fires 72-1999 shall be followed. Environments with large amounts better than smoldering fires. Because fires develop in different of dust, dirt or high air velocity require more frequent mainte- ways and are often unpredictable in their growth, neither type nance. A maintenance agreement should be arranged of detector is necessarily best and a given type of detector through the local manufacturer's representative. Maintenance may not provide adequate warning of a fire. should be scheduled monthly or as required by National and/ Smoke detectors cannot be expected to provide adequate or local fire codes and should be performed by authorized pro- warning of fires caused by arson, children playing with fessional fire alarm installers only. Adequate written records of matches (especially in bedrooms), smoking in bed, and violent all inspections should be kept. explosions (caused by escaping gas, improper storage of flammable materials, etc.). Precau-L-4-2003.fm 2 NFS-3030 Operations Manual 51344:C 11/4/03 Technical Manuals Online! - http://www.tech-man.com Installation Precautions Adherence to the following will aid in problem-free installation with long-term reliability: WARNING - Several different sources of power can be Like all solid state electronic devices, this system may connected to the fire alarm control panel. Disconnect all operate erratically or can be damaged when subjected to light- sources of power before servicing. The control unit and asso- ning-induced transients. Although no system is completely ciated equipment may be damaged by removing and/or insert- immune from lightning transients and interferences, proper ing cards, modules, or interconnecting cables while the unit is grounding will reduce susceptibility. Overhead or outside energized. Do not attempt to install, service, or operate this aerial wiring is not recommended, due to an increased sus- unit until this manual is read and understood. ceptibility to nearby lightning strikes. Consult with the Techni- CAUTION - System Reacceptance Test after Software cal Services Department if any problems are anticipated or Changes. To ensure proper system operation, this product encountered. must be tested in accordance with NFPA 72-1999 Chapter 7 Disconnect AC power and batteries prior to removing or after any programming operation or change in site-specific inserting circuit boards. Failure to do so can damage circuits. software. Reacceptance testing is required after any change, Remove all electronic assemblies prior to any drilling, filing, addition or deletion of system components, or after any modifi- reaming, or punching of the enclosure. When possible, make cation, repair or adjustment to system hardware or wiring. all cable entries from the sides or rear. Before making modifi- All components, circuits, system operations, or software func- cations, verify that they will not interfere with battery, trans- tions known to be affected by a change must be 100% tested. former, and printed circuit board location. In addition, to ensure that other operations are not inadvert- Do not tighten screw terminals more than 9 in-lbs. ently affected, at least 10% of initiating devices that are not Over-tightening may damage threads, resulting in reduced ter- directly affected by the change, up to a maximum of 50 minal contact pressure and difficulty with screw terminal devices, must also be tested and proper system operation ver- removal. ified. Though designed to last many years, system components This system meets NFPA requirements for operation at 0°C can fail at any time. This system contains static-sensitive to 49°C (32°F to 120°F) and at a relative humidity (noncon- components. Always ground yourself with a proper wrist strap densing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at before handling any circuits so that static charges are removed 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life from the body. Use static-suppressive packaging to protect of the system's standby batteries and the electronic compo- electronic assemblies removed from the unit. nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this Follow the instructions in the installation, operating, and pro- system and all peripherals be installed in an environment with gramming manuals.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    72 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us