Building a Better Chimney

Building a Better Chimney

Building a better chimney Use proper detailing and the best materials to avoid moisture-penetration problems By Christine A. Subasic 2 1 6 S p e c i f i c a t i o n f o r F a c i n gB r i c k moisture absorbed under pres- for Grade SW (severe weathering). sure, such as from driving rain or Because they have a higher com- freezing effects. The cold-water e s i g n e r s a n d b u i l d e r s o f pressive strength and are less ab- absorption is a measure of the residential chimneys some- sorptive than Grade MW (moder- moisture absorbed by a unit under Dtimes fail to realize the se- ate weathering), Grade SW brick normal conditions. verity of the conditions to which meeting this standard are durable H o w e v e r, i n a re a s w i t h l a rg e a chimney is exposed. As a result, e v e n i f f ro z e n w h i l e s a t u r a t e d a m o u n t s o f r a i n o r n u m e ro u s efflorescence, staining, water pen- with water (Ref. 1). freeze-thaw cycles, consider using etration, and deterioration of ma- ASTM C 216 requirements limit e v e n l e s s a b s o r p t i v e m a s o n r y sonry chimneys may occur, un- the boiling-water absorption for units—Class SX paving brick con- less precautions are taken. Grade SW to 17% and the cold- forming to ASTM C 902 Specifica- Most problems associated with water absorption to 13.3% for an tion for Pedestrian and Light Traf- masonry chimneys, whether aes- average of five brick. The boiling- fic Paving Brick. Because they are thetic or more substantial, are re- w a t e r a b s o r p t i o n re f l e c t s t h e laid horizontally, pavers typically lated to water. Chimneys can be exposed to significant amounts of Expansion joint and sealant water under a variety of climatic conditions. Both the warm rains of Sloped concrete the South and the cold wind-driv- crown 2" min. en rains and snow of the North- east can be damaging to a mason- ry c h i m n e y, p a rt i c u l a r l y i f t h e 2" min. c h i m n e yi si m p ro p e r l yc o n s t ru c t e d or poorly maintained. In addition, the thermal cycling that occurs Drip due to varying outdoor tempera- tures and normal chimney usage Vent can create a potentially damaging 1 2 ⁄2" min. environment. Flashing To withstand the rigors of such an environment, a chimney must b e p ro p e r l y d e s i g n e d a n d c o n - Chimney structed of the best materials. wall 1" space Chimney exterior Clay flue liner The materials used to construct exterior chimney walls are sub- ject to the most severe exposure. If brick is used, it should conform Figure 1 Chimney crown to the requirements of ASTM C are subject to more severe weath- er exposure than brick in vertical applications. Consequently, the Clay flue liner Chimney wall absorption limits found in C 902 are considerably lower than those in C 216 (Ref. 2). Counterflashing ASTM C 902 limits cold water absorption to 8.0% and boiling water absorption to 10.3% for an average of five units. As a result, chimneys built with C 902 brick absorb less water and should pro- 3" min. lap Roof vide better durability than those 4" min. Base flashing built from C 216 brick. Mortar used on the exterior of a chimney can be Type N or S mor- 4" min. tar made from portland cement and lime or from masonry cement. In areas with wind pressures over 25 psf, the Brick Institute of Amer- i c a ( B I A ) re c o m m e n d s Ty p e S portland cement-lime mortar for its high tensile strength. Under Figure 3 Through-wall counterflashing these conditions, chimneys made w i t h o t h e r m o rt a r s a re m o re prone to cracks at the brick/mor- and the exterior elements, only for Pier Test for Refractory Mort a r s , tar interface. non-water-soluble refractory mor- m e d i u m - d u t y. tars should be used for laying the Chimneys used to vent high-effi- Chimney interior flue, as specified by the National ciency gas appliances are subject The interior of a masonry chim- Fire Protection Association stan- to highly acidic condensate. Use ney typically is constructed with d a rd N F PA 2 1 1 ( R e f . 3 ) . T h e s e clay flue liners and an acid-resis- clay flue liners conforming to the mortars should meet the require- tant or chemical-resistant mortar re q u i re m e n t so fA S T M C 3 1 5 S p e ci- ments of ASTM C 105 Specificati o n in these chimneys for best perfor- fication for Clay Flue Linings. Be- for Ground Fire Clay as a Ref r a c t o r y mance. Do not use portland ce- cause of their exposure to mois- M o rt a r f o r L a y i n g U p F i re c l a y m e n t o r c a l c i u m a l u m i n a t e c e- ture from condensing flue gases B r i c k o r A S T M C 1 9 9 Test Method m e n t b e c a u s e o f t h e i r l o w a c i d re s i s t a n c e . To accommodate the wide tem- Base flashing Tab perature changes experienced by the flue, include a 1-inch air space b e t w e e n t h e e x t e r i o r c h i m n e y walls and the flue. In high seismic a re a s , t h i s s p a c e i s f i l l e d w i t h grout for structural reasons, but reinforcement placed within this space helps to accommodate the thermal stresses that occur. Counter- flashing Crown Better chimney design always in- cludes a crown to protect the chimney walls and interior fro m rain and snow. A portland cement c o n c rete crown is re c o m m e n d e d . Whether prefabricated or cast-in- p l a c e , a c o n c re t e c ro w n s h o u l d b e a t l e a s t 2 i n c h e s t h i c k w i t h a s l o p e of 3 inches or more to pro m o t e Base flashing drainage, as shown in Figure 1 . T h e c h i m n e y c ro w n s h o u l d p ro- 1 Figure 2 Intersection with the roof ject at least 2 ⁄2 inches past the face of the chimney wall below and in- corporate a drip. This re d u c e sw a- chimney walls to form a drip edge. place. But use this detail cautious- t e r ru n d o w no nt h e chimney walls. It should pass through the chim- ly because it does not provide 3 Leave a ⁄8 -inch gap between the ney walls into the space between drainage for water entering the chimney crown and the flue to al- the walls and the flue. The flash- chimney space. low for thermal expansion of the i n g s h o u l d b e t u rn e d u p w a rd I n t h e n o rt h e a s t e rn U n i t e d flue. The gap should be filled with against the flue and extend up to States, where driving rains are se- a backer rod and an elastomeric the top of the crown (see Figure 1). vere, tray or pan flashing may be sealant, such as a silicone or a A backer rod and sealant placed used. A solid sheet of flashing, of- polysulfide sealant. Extend the b e t w e e n t h e f l a s h i n g a n d t h e ten made of lead, is cut to match flue at least 2 inches or the mini- the chimney cross-section. Holes m u mc o d e - re q u i re dd i s t a n c ea b o v e crown provides a tight barrier to are then cut for the flue(s).

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    4 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us