The Start up of the CUORE Experiment at LNGS CUORE

The Start up of the CUORE Experiment at LNGS CUORE

The start up of the CUORE experiment at LNGS CUORE Photo credit: Yury Suvorov Antonio Branca @ INFN Padova On behalf of the CUORE Collaboration WIN2017 @ UC Irvine – 19-24 June 2017 Double beta decay (DBD) CUORE 2ν DBD: (A, Z) → (A, Z + 2)+ 2e− + 2ν 0ν DBD: (A, Z) → (A, Z + 2)+ 2e− - proposed in 1935 by - proposed in 1937 by Maria Goeppert-Mayer; Eore Majorana; - 2nd order process allowed - requires pHysics beyond in the Standard Model; Standard Model; τ ~ 1019−21 yr τ >1024−25 yr Energy spectrum of the two electrons in DBD 0ν DBD Signature: monocHromac line in the energy spectrum at the energy value smeared by detector resoluOon! 19-24 June 2017 A. Branca - WIN2017 @ UCI 2 Double beta decay (DBD) II CUORE EffecOve Majorana mass m = f (Δm , Δm , m ,α ,α ,δ) THe 0ν DBD Half-life: ββ 1,2 2,3 1 1 2 2 0⌫ 1 0⌫ 0⌫ 2 mββ (T1/2)− = G (Q, Z) M |h 2 i| | | me PHase space 5 Nuclear Matrix Element factor ~Q ßß (theoreOcal uncertainty ~2-3) (accurately calculable) ISM | 9 IBM ν 0 QRPA-T |M 8 QRPA-J Physics consequences if 0ν DBD is observed: PHFB GCM 7 6 • proof of the Majorana nature of neutrino; 5 • constrain on the neutrino mass HierarcHy and scale; 4 3 • lepton number violaon (ΔL = 2): a possible source 2 of maer-anOmaer asymmetry in the universe; 1 0 48Ca 76Ge 82Se 96Zr 100Mo 116Cd 124Sn 128Te 130Te 130Xe 150Nd 19-24 June 2017 A. Branca - WIN2017 @ UCI 3 Sensitivity CUORE Half-life corresponding to the minimum number of detectable signal events above background at a given C.L. Isotopic abundance Detector mass Measuring Ome 0 sens. M ⋅t (also “live Ome”) T ν ∝i.a.⋅ε ⋅ ( 1/2 ) ΔE ⋅ B Background Detector efficiency Energy resoluon In order to build a HigH sensiOvity experiment: • select 0v DBD candidates with HigH natural isotopic abundance or enricHed; • HigH detector mass; • good detector stability over a long period; • extremely HigH energy resoluOon; • extremely low background environment; 19-24 June 2017 A. Branca - WIN2017 @ UCI 4 Bolometric technique in CUORE CUORE (A) Copper frame: A 10 mK Heat sink (B) PTFE holders: D weak thermal coupling (D) Si joule heater: C reference pulses (C) TeO2 crystal: E B energy absorber RadiaEon: (E) NTD Ge thermistor: energy deposit 3200 E resisOve thermometer 3000 ΔT = 2800 C(T) Amplitude [mV] Bolometer: detector and source 2600 readout of 0ν DBD. HigH efficiency and ΔT 3 2400 ⎛ T ⎞ resoluOon; C(T) = ⎜ ⎟ 2200 ⎝ϑ D ⎠ 2000 Low temperature needed: 1800 J mK @T =10mK ⇒ C ~ 10−9 ; ΔT = 0.1 ; τ ~ 1s; 1600 0 0.5 1 1.5 2 2.5 3 3.5 4 K MeV Time [s] 19-24 June 2017 A. Branca - WIN2017 @ UCI 5 A rare event search CUORE 24−25 SearcHing for a rare event (0ν DBD): ………………………τ >10 yr Extremely important to reduce as mucH as possible backgrounds: a. natural radioacOvity from outside the detector: • cosmic ray muons induced background; • neutron and gamma fluxes; b. natural radioacOvity from the detector itself: • long-lived nuclei (40K, 238U, 232Th); • anthropogenic radioacOve isotopes (60Co, 137Cs, 134Cs); • cosmogenical radioacOve isotopes (60Co); c. mecHanical vibraon noise: • cryogenic system and seismic noise; 19-24 June 2017 A. Branca - WIN2017 @ UCI 6 CUORE installed @ LNGS CUORE CUORE @ Hall A • average depth: ~3600 m.w.e. • muon flux: ~3×10-8 μ/(s cm2) • neutron flux: < 4×10-6 n/(s cm2) • gamma flux: ~0.73 γ/(s cm2) 19-24 June 2017 A. Branca - WIN2017 @ UCI 7 Suspension System CUORE Abatement of vibrations: detector mechanical Y-Beam decoupling from the outside environment: • detector hung by the Y-Beam through Minus-K cables made of stainless steel tie bars, Kevlar ropes and copper bars (damping the MSP horizontal oscillations); • 3 minus-K springs connect the Y-Beam to the Main Support Plate, MSP (attenuating the noise of ~35 dB); Lead sHield • elastometers at the structure basis (seismic H3BO3 isolators); panels Radioactive background reduction: Polyethylene • outer neutron shield: polyethylene + borated powder; • outer gamma shield: lead shield; Elastometers 19-24 June 2017 A. Branca - WIN2017 @ UCI 8 Cryogenic System CUORE Specifics: • Fast Cooling System: T down to ~40 K; • 5 Pulse Tubes cryocooler: T down to ~4 K; • Dilution Refrigerator: T operations 10 mK; • Nominal cooling power: 3 µW @ 10 mK; • Cryogen-free cryostat: high duty cycle; Cool down ~15 tons @ T < 4 K and ~1.5 tons @ T = 10 mK in a few weeks. Radioactive background reduction: • material screening and accurate selection to ensure radiopurity; • lead shielding (Roman and modern Pb); 19-24 June 2017 A. Branca - WIN2017 @ UCI 9 The CUORE “core” CUORE 988 TeO2 crystals arranged in 19 towers (13 floors - 52 crystals eacH): • 130Te for 0v DBD: good Q-value (2528 keV) in low β/γ region, higH natural abundance (34.17%); • total TeO2 mass of 742 kg (206 kg of 130Te); RadioacOve background reducOon: • minimizaon of material/ surface facing the crystals; • developed a stringent protocol for the tower assembly and All 19 towers installed material cleaning (tested on between July-August 2016 predecessor CUORE-0); A single CUORE tower 19-24 June 2017 A. Branca - WIN2017 @ UCI 10 CUORE0: the first CUORE tower CUORE First detector tower built using the new tecHniques and assembly line developed for CUORE: • operated from 2013 to 2015 in old Cuoricino cryostat; • proof of concept for CUORE; • 0ν DBD searcH by itself; ) 6 ) 4 σ σ 4 2 2 0 0 –2 −2 −4 Residual ( Residual –4 Residual ( −6 18 2560 2570 2580 2590 2600 2610 2620 2630 2640 2650 0.25 208 2 Summed calibration data Tl γ 16 χ /NDF = 43.9/46 4 Projected fit 14 0.2 10 12 0.15 3 Te X-ray 10 10 escapes 8 0.1 102 Events / (2 keV) Events 6 4 0.05 2 10 Counts / (0.5 keV) Event RAte (counts/(keV kg yr)) (counts/(keV RAte Event 0 0 2470 2480 2490 2500 2510 2520 2530 2540 2550 2560 2570 1 Reconstructed Energy (keV) 2560 2570 2580 2590 2600 2610 2620 2630 2640 2650 RESULTS: Reconstructed Energy (keV) 24 Ø 0νββ upper limit: T1/2(0ν) > 4×10 yr (@ 90% C.L.) combined CUORE0 + Cuoricino results; ü ROI background: 0.058 ± 0.004 c/(keVkgyr); ü ResoluOon: 5.1 ± 0.3 keV FWHM @ 2615 keV; ResoluOon consistent with the CUORE goal of 5 keV. 19-24 June 2017 A. Branca - WIN2017 @ UCI 11 Material cleaning and assembling CUORE Production of the TeO2 crystals: • by Shanghai Institute of Ceramics, Chinese Academy of Science (SICCAS); • two successive crystal growths starting from high purity synthetized TeO2 powder; • cutting, orienting and shaping from raw ingots and surface polishing and packaging; • all operations performed in a dedicated clean room and following strict controls to limit radioactive contamination; Cleaning of copper surfaces (tower parts and 10 mK cryostat shield): • new cleaning techniques developed at LNL; • tumbling, electropolishing, chemical etching, magnetron plasma aimed at the removal of a thin layer of material (from 1 µm to 100 µm); 19-24 June 2017 A. Branca - WIN2017 @ UCI 12 Material cleaning and assembling CUORE Strict protocol adopted for each step of the CUORE towers construction: all in N2 atmosphere and within glove boxes to avoid radioactive recontamination; 1. sensors gluing 2. tower assembly 3. wire bonding 4. tower storage 19-24 June 2017 A. Branca - WIN2017 @ UCI 13 Background reduction effectiveness CUORE β/γ dominated α dominated 208Tl 210Po 190Pt 234U/226Ra/230Th 238 222Rn U 218Po Comparison of the background in Cuoricino and CUORE-0 238 232 Background indexes (counts/(keV•kg•yr)) • Material cleaning: U and Th α lines reduced (~ factor of 7); 0ν DBD region α region (2.47-2.58 MeV) (2.7-3.9 MeV) • Tower assembly in N2 atmospHere: 238U γ lines reduced (~ factor 2/3); Cuoricino 0.169 ± 0.006 0.110 ± 0.001 • Same Cuoricino cryostat: 232Th γ lines CUORE-0 0.058 ± 0.004 0.016 ± 0.001 not reduced; 19-24 June 2017 A. Branca - WIN2017 @ UCI 14 CUORE background projection CUORE Main background index in the 0ν DBD region expected for the various components of CUORE Measured in Preliminary CUORE-0 Material expected screening dominant contribuOon from the Cu of the towers structure LNGS Fluxes Projected total BI in the 0ν DBD region is consistent with CUORE background goal (10-2 counts/(keV•kg•yr)): counts BI = (1.02 ± 0.03(stat.)+0.23 (syst.))⋅10−2 (Preliminary) −0.10 kev⋅ kg⋅ yr 19-24 June 2017 A. Branca - WIN2017 @ UCI 15 Cryostat commissioning CUORE Commissioning completed in MarcH 2016: 300 K • stable base T = 6.3 mK over 70 days (no 40 K detector, full load); • full detector read-out cHain (electronics, DAQ) 4 K test, temperature stability with Mini-Tower (8 crystal tower); 600 mK 50 mK 10 mK Mini-Tower resoluOon without noise opOmizaon. 19-24 June 2017 A. Branca - WIN2017 @ UCI 16 CUORE Installation CUORE Towers installaon completed 10 mK Cu shield closed Lead sHield installed Aug 2016 Cryostat closed Cables rouOng Sep – Nov 2016 Nov 2016 19-24 June 2017 A. Branca - WIN2017 @ UCI 17 CUORE cooldown and commissioning CUORE • cooldown started on Dec 5, 2016; • lasted about 3.5 weeks (without taking A•er the cooldown into account tecHnical stops for system started a pHase of debugging); detector opOmizaon • on Jan 26, 2017 reached a base temperature of T = 7 mK; Diode thermometer at 10mK plate First pulse observed on Jan 27, 2017 cryogenics debugging 102 electronics debugging T (K) 10 12/05-12:16 12/22-14:10 01/08-16:04 01/25-17:59 Time 19-24 June 2017 A.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    28 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us