Ventilated Attics and Un-Vented Roof Assemblies David B. Strunk, P.E., C.E.M. Strunk-Albert Engineering Attic ventilation is common practice, and if installed properly, will function without a problem. However, attics and roofs can be designed and constructed without ventilation. In fact un-vented roof assemblies, such as conditioned attics and un-vented cathedral ceilings, are generating more interest and are becoming a more common construction technique. The decision to vent or not to vent is a design and construction choice not a requirement by the building code. Model building codes allow both vented and un- vented roof assemblies. The physics of heat and moisture transfer affect the design of attic or roof ventilation but does not limit the choice. The suggestion for attic ventilation first occurred in the mid 1930s and later became a BOCA code requirement in 1948. Attic ventilation has become firmly established as an important feature in sloped roof construction, most commonly found in residential and light commercial construction. Lack of attic ventilation is often the cause of moisture, mold, and rotten wood. Many asphalt shingle manufactures have requirements and guidelines for attic ventilation in their installation instructions. Providing proper attic ventilation can at times be difficult with complex roof designs. The more complex the roof geometry, the easier it is to construction the roof assembly in an un-vented manner. With complex roof designs, dormers, valleys, hips, skylights, soffits, and multiple service penetrations it is often impractical to construction a vented roof assembly with an airtight interior air barrier at the ceiling plane. With floor space being tight and costly, it is common to locate mechanical equipment and ductwork in the attic space. This, along with recessed lighting, results in numerous penetrations that compromise the drywall air barrier and allows high exfiltration or infiltration between the occupied space and the ventilated attic. All ductwork will leak; some more than others. This means conditioned air is entering the ventilated attic. High exfiltration and duct leakage allows heat and moisture to enter the attic. Moisture can condense on the cold surfaces and the heat can cause ice dams when there is snow on the roof. Ventilated Attics and Un-Vented Roof Assemblies Page 1 of 19 David B. Strunk, P.E., C.E.M. Photo – 1: Condensation can occur in an attic space when there is not adequate ventilation or there is excessive humid air transfer to the attic. Photo – 2: Ice dams occur because of excess heat on the underside of the roof deck. High infiltration to the attic or duct leakage can cause heat build-up in the attic. Ventilated Attics and Un-Vented Roof Assemblies Page 2 of 19 David B. Strunk, P.E., C.E.M. Photo – 3: Penetrations of the air barrier allow for high infiltration or exfiltration ( air movement between the conditioned space and attic). Photo – 4: Ventilated attics without an air barrier is like not having any insulation at all. The movement of air between the conditioned space and attic space is very high and will use a considerable amount of energy. In addition, the conditioned space is uncomfortable because of cold air drafts from the ceiling. Ventilated Attics and Un-Vented Roof Assemblies Page 3 of 19 David B. Strunk, P.E., C.E.M. There are significant energy advantages to moving the thermal boundary to the underside of the roof deck and not ventilating the attic space. The mechanical equipment is now located in conditioned space so any air leakage or heat loss is to the conditioned space not the unconditioned attic. The first reaction of most people is that this will have a high heat loss because of the additional volume to heat. But the reduction in infiltration through the air barrier and the elimination of duct air leakage more than offsets the additional heat loss from the larger conditioned volume of conditioned space. Many building owners are happy to have the additional space provided by a conditioned attic. • Duct leakage can be as high as 20% of the total air flow. • Leakage can contribute to ice dams • Leakage is a high energy loss. • Transmission loss from the ductwork is higher than building components because the average R value of 2” fiberglass duct wrap is about R=6 compared to R=30 in the ceiling. • Leakage can cause condensation to form on cold surfaces. Figure – 1: HVAC External to the Thermal Envelop. Ventilated Attics and Un-Vented Roof Assemblies Page 4 of 19 David B. Strunk, P.E., C.E.M. • Duct leakage is to the conditioned space not the ventilated attic. • More energy efficient compared to Figure – 1. • Less penetrations of the air barrier, which means less infiltration or exfiltration. Figure – 2: HVAC Interior to the Thermal Envelop. Attic ventilation is provided for three main reasons; to allow dissipation of any moisture build-up, minimize occurrence of ice dams on the roof, and to cool the attic in the summer. Attic ventilation is also cited as extending the life of asphalt shingles. In fact, many asphalt roofing manufacturers warrant their products only for ventilated attics. Their argument is that shingles on an un-vented roof are hotter and more prone to moisture damage and accelerate aging. The temperature of the shingles is almost exclusively determined by absorbed solar radiation, convective heat loss from wind, and infrared radiation loss to the sky. A study performed in 1992 found that attic ventilation lowered the peak temperature of the sheathing surface directly below the shingles by about 10 degrees F. The peak temperature below the shingles on un-vented cathedral ceiling roofs was also higher than on vented cathedral ceilings. A difference of 10 degrees F translates into a relative change in absolute temperature of less than 2%. As the rate of aging is proportional to the absolute temperature, the effect of this modest rise in temperature is likely to small. The color of shingles has a greater effect on the shingle temperature, and therefore durability, than does attic ventilation. Research performed by Simpson and McPherson in 1997 found that white roofs were as much as 36 F cooler than gray roofs and as much as 54 F cooler than brown roofs. Attic ventilation provides only a minor effect for lowering shingle temperatures. GAF Materials Corp. maintains their warranty for shingles on an un-vented roof. Ventilated Attics and Un-Vented Roof Assemblies Page 5 of 19 David B. Strunk, P.E., C.E.M. Design Objectives: The elimination of air movement is the main objective when designing a roof or attic to be free of moisture problems, reduce ice dams, and control heat transfer. This is accomplished by the proper installation of an air barrier with a ventilated attic or un- vented roof assembly. Vapor diffusion is the transfer of moisture in vapor form independent of air movement. It is caused by differences in vapor pressure. Vapor in higher humidity areas want to move to a lower humidity area. Incorporation of vapor barriers to control vapor diffusion is of secondary importance and often not needed if air movement is controlled. Except in Climate Zones 6 & 7 where a vapor retarder is recommended on the conditioned side of the assembly. Climate Regions: The International Code Council breaks the United States into various climate regions. These are used to determine insulation values. It also helps determine the need and placement of vapor retarder/barriers. The mid-atlantic region is in Climate Zone 4 & 5. Northeast PA and northern NJ are in Climate Zone 5. Map – 1: International Codes Council – Climate Zones Ventilated Attics and Un-Vented Roof Assemblies Page 6 of 19 David B. Strunk, P.E., C.E.M. Residential Code: It is just of recent years that the un-vented option has been researched and allowed by model building codes. The 2009 International Residential Code (IRC) states the requirements for both ventilated attics and un-vented roof assemblies. (from the IRC 2009) SECTION R806 ROOF VENTILATION R801.6 Ventilation required . Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow. Ventilation openings shall have a least dimension of 1/16 inch (1.6 mm) minimum and 1/4 inch (6.4 mm) maximum. Ventilation openings having a least dimension larger than 1/4 inch (6.4 mm) shall be provided with corrosion-resistant wire cloth screening, hardware cloth, or similar material with openings having a least dimension of 1/16 inch (1.6 mm) minimum and 1/4 inch (6.4 mm) maximum. Openings in roof framing members shall conform to the requirements of Section R802.7. R806.2 Minimum area . The total net free ventilating area shall not be less than 1/150 of the area of the space ventilated except that reduction of the total area to 1/300 is permitted provided that at least 50 percent and not more than 80 percent of the required ventilating area is provided by ventilators located in the upper portion of the space to be ventilated at least 3 feet (914 mm) above the eave or cornice vents with the balance of the required ventilation provided by eave or cornice vents. As an alternative, the net free cross-ventilation area may be reduced to 1/300 when a Class I or II vapor barrier is installed on the warm-in-winter side of the ceiling. R806.3 Vent and insulation clearance . Where eave or cornice vents are installed, insulation shall not block the free flow of air.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages19 Page
-
File Size-