DI-10 Service Manual

DI-10 Service Manual

DI-10 Check Weii ghii ng Scall e When Accuracy Counts SSeerrvviiii ccee MMaannuuaallll 73355 1 CONTETS PAGE 1. EXTERNAL VIEW. 2 2. DISPLAY & KEYS. 2 2-1. Display. ------____---------------- 2 2-2. Sign lamps. --_____---------------- 3 2-3. Keys. --------_____---------------- 4 3. SET UP. 5 4. SPECIFICATIONS. 7 5. FEATURES. 8 6. OPERATION INSTRUCTION. 9 6-1. Power ON. -_---_____---------------- 9 6-2. One touch tare. ___---------------- 10 6-3. Digital tare. _____---------------- 11 6-4. Digital tare during weighing. ------_ 12 6-5. Set point setting _---------------- 13 6-6. Addition and subtraction. _-------- 15 6-7. Counting. _________--_---_-___----- 17 6-8. NET/GROSS display ___---------------- 17 6-9. Data ti Time setting ----------------- 18 6-lO.LB/KG conversion ___---------------- 19 7. CALIBRATION. 20 a. SPEC. LIST. 22 9. ERROR MESSAGE LIST. 25 2 1. EXTERNAL VIEW Dl,-10 W=240 D=260 H = 92 (mm) 2.DISPLAY & KEYS. 2;1*Display * Weight value is displayed loaded on the scale. * Weighing unit, sign lamps and filling graphic for set pint are displayed. 3 ,,.~~ ,, 2-2.sign lamps [-o-J Zero lamp : ON, when display is true zero. Tare lamp : ON, when tare is subtracted. m [r] Net lamp : ON, when net weight is displayed. Gross lamp : ON, when gross weight is displayed. c3i3 BATT. lamp : ON, when battery run out. m [r) W.S lamp : ON, when weight is in stable condition. I] HI lamp : ON, when weight value reached to "HI" set point programmed. (1 OK lamp : ON, when weight value reached to "OK" set point programmed. ( LO lamp : ON, when weight value reached to "LO" set point programmed. 2-3.Keys Total key : Use for total weight call and print out. 0* Use for weight data print out without - addition. Plus key : Use for weight data addition and print out. Minus key : Use for weight data subtraction and print 0 out. Numeric : Use for data entry. - a-0 9 key ON/OFF key : Display ON/OFF key.(Not for main power.) Mode key : Weighing conversion key. NET/GROSS : Display change for NET and GROSS. key Feed key : Paper feed key.(In case of PRINTER connection) Set point : Set point programming for "HI'~,"OK" and . key "LO" . :‘=:Sample key : Use for number of sample entry on 0 counting mode. 0-1 3 Tare key : Use for tare reduction. Re-zero key : Weight display re-zeroing. 0CL Clear key : Use for data clear. 0# Code key : Use for programmed code number read out. 5 3.SET UP l-Put display side on the soft cloth or similar. 2.Remove rear lid and brackets by 6 screws. 3.Fix the cable to connector A. 4.Re- mount the rear lid and brackects. 6 l.Remove the right side cover. 2.Remove the dry cell box. 3.Put the dry cell in the box. ( 6 pcs.) (Please pay attention to the polarity of the dry Cells) 4.Re-mount the dry cell box. 4. SPECIFICATION MODEL,SPEC,, * Power source : D.C 12V 0.5A (AC/DC adaptor) D.C 1.5V x 6 pcs. (Dry battery) * Operating temperature : -10 . +4o*c * Operating humidity 15 . 85% RH. * Power consumption 1 w/h. ANALOG SPEC: * Input sensitivity : 0.5mV/V to 4mV/V * Zero adj. range : -6 mV . 30 mV. * L/C applied voltage : DC 12.V. * Temp. characteristic : ZERO . ..+(0.2uV + 8ppm of ZERO)/"C SPAN _ ..+ 8 ppm/"c * Speed of A/D conversion: 8 or 16 times/set. (selectable) * Non linearity : 0.01 8 DISPLAY_SPEC;: * Weight display : 6 digits. * Tare : 6 digits. * Set point 1 (LO) : 6 digits. * Set point 2, (OK) : 6 digits. * Set point 3 (HI) : 6 digits. * Display total. : 6 digits. * Weighing unit : 4 kinds "g","kg","lbs","oz" & "dwt" * Sign lamps : 9 kinds "ZERO","TARE","NET","GROSS" "BATT" "was", UHI", WOK", "Lo" * Filling graphic : 2 kinds rough and fine. * Printer : Model 150 II 16 digits/line. 5 x 7 dots/chars. * Print method : Dot impact printer Ink ribbon cartridge. * Items to be print : Date(MM.DD.YY.)...... 2 digits each. : Time(HH.MM) . 2 digits each. : Code No. 6 digits. : Weight . 6 digits. : Total weight . 6 digits. : No. of transaction... 4 digits. : Signs "+" . Addition ?'-'I . Subtraction. (1* ?I . Non addition. "T" . Total. "kg" . kg mode. “lb” . lb mode. * Paper : Normal paper is used. * Print color : Black or purple. 123456 t 506.80 kg 123456 + 206.06 ks 123456 - lBB.RO I:9 5. FJZATURES _ *, LCD graphic display is used for filling in indicator. * Battery drive available. (about 100 to 200 hours) * Up to 4 x 350o load cell can be drive in case AC/DC adaptor is used. ( in the case of battery drive, only one 350n load cell can be drive.) * 5 kinds of weighing mode kg,g,lbs,oz and dwt. * One touch tare, Digital tare, Digital tare during weighing. * Addition & subtraction. ? NET/GROSS conversion. * Automatic zero tracking. * Automatic print. * Automatic calibration. * Automatic power off. * Data out put by RS-232C for external device. (Option) * Set point data out put. (Option) * Built in printer. (Option) * Code No. printing. * Da-te & time printing. * Counting function. * Programmable scale capacity and scale interval. * Meets or exceeds the requirements of OIML class 3 in case of l/3000 display resolution. 9 6 OPERATION INSTRUCTION ZERO : Zero lamp W.S: Weight stable TARE : Tare lamp HI : "HI" set point NET : Net lamp OK : "OK" set point GROSS: Gross lamp LO : "LO" set point BATT.: Kg mode l-Set dry cell or AC/DC adaptor ,, I, II II P 1.0 3 11 then depress 0Ea key. * P 1.03 is program version number. II I, II * DiSDlaY_ _ scrolls 000000 to II 0 0 0 0 0 0 11 999999 then all the sign ~ lamps, weight unit and filling in graphic are displayed for checking purpose. * If you want to stop the 10 2.Ready to weigh. * After this page, all the mxa descriptions are written based on 60.00kg/O.O2kg scale. u I - m. I (When unknown tare weight) l-Place tare weight. *Ready to weigh. 3.Place weight. (Ex. 4.56 kg) 4.Remove tare & weight 5.Depress *T3 key. II I I 0 I O’.! *Tare weight is cleared. *Ready for next OperatiOn. mm u (When known tare weight) l.Enter tare value by numeric key. (Ex. 2.34 kg) 2.Depress *T3 key. I4 II 1 0 II - 2. 3 4mn I 3.Place tare weight 2.34 kg. *Ready to weigh. 12 4.Place weight. (Ex. 4.56 kg) 5.Remove tare & weight. ii - 1': 0 oa; b-Depress 0+q3 key. *Tare is cleared. l-Place tare & weight. 5'1.5 6m' tare : 1.00 kg weight: 4.56 kg total : 5.56 kg 2.Enter tare value by numeric u key. 3. Depress +T key. 03 4.Remove tare & weight. 5. Depress 0*T3 key. *Tare is cleared. l-Depress (5) key. II I, II 0 II 6 0.0 0 1 *Scale capacity(60.00kg) is set automatically for "LO", "OK" & "HI" when no data. *See "NOTE" for the detail. m ! 2.Enter set point for "LO". II II II 10.0 0 l (Ex. set point "LO"=lO.OO kg) ~ set point "OK"=20.00 kg set point "HI"=30.00 kg Enter J 3.Depress fsj key. 0 Enter set point for "OK". Enter 4.Depress 0f9 key. Enter set point for "HI". Enter 5.Depress 0fs> key. *Completed & ready to weigh. NOTE : * The filling graphic will be as follows when same value are set to each set point. Ex.) 60.00 kg/O.02 kg. Set point "L0"="0K"="H1"=60.00 kg. 45.02 --- 60.00 kg 30.02 --- 45.00 kg 60.00 kg 15.02 --- 30.00 kg s---------=15 0.02 --- 15.00 kg 4 kgstep * The filling graphic will be as follows when different value are set to each set point. Ex.) 60.00 kg/O.02 kg. Set point "LO"=lO.OO kg,"OK"=20.00 kg,"HI"=30.00 kg 0.02 to 10.00 kg _ 7.52---lo.00 kg _ 5.52--- 7.50 kg 2.52--- 5.50 kg _ 0.02--- 2.50 kg -10.02 to 20.00 kq I- I- - I- - ' I -cI I 20.02 to 30.00 kg 30.02 to CAPACITY l-Enter Code No. by numeric key.,, I, 11 II 1 2 3 4. 5 6 11 Ex. Code No.=123456 @.@@@a3 I! 2.Depress # key. II I, Ii 0 II 0. 0 OmII I 3.Place weight then depress II II key. 1 0. 0 Olall Ex. 10.00 kg *Total weight appears and display flashes 4 times. u J 4.Remove 10.00 kg and place II II II another weight then depress 11 2 5, 0 Orall 0+ key. Ex. 15.00 kg *Total weight appears and display flashes 4 times. - 5.Depress - key for II I, II w correction.l[ 1 0. 0 omjl (subtraction) I 6.Remove weight, enter weight II II II value if it is known weight. I/ 1 2.3 4 11 (fjg4~@@ 7.Depress a key for addition,, II II L.2 II 2 2. 3 4m11 then depress 0* key to cal up total weight. 8.Depress * key again to II II II 0 II 0. 0 OBll print out total weight. .L, l.Place samples 10 PCS., then II I, II m II 1 0 II depress w key. II EX. 10 PCS. sample = 0.10 kg *If the sample weight is less than 0.1% of scale capacity, m will be displayed.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    29 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us