Impacts of room temperature on the performance of a portable propane air conditioner Ahmad Sharifian1, Jeri Tangalajuk Siang2 1,2Computational Engineering and Science Research Centre (CESRC), School of Mechanical and Electrical Engineering, Faculty of Health, Engineering and Science, University of Southern Queensland, Toowoomba, Australia. Email of corresponding author: [email protected] Abstract The performance of a portable propane air conditioner system, in which the temperatures of the air passing over the condenser and evaporator are equal, has been experimentally investigated under different room temperatures and refrigerant charge levels. The research has been carried out in a range of room temperatures from 20°C to 35°C and in undercharge, standard charge and overcharge conditions. The results show that, at higher room temperatures, the refrigerant temperature in all parts of the system, the density of the refrigerant at the inlet and outlet of the condenser, mass of the refrigerant in the compressor, the mass flow rate of the refrigerant and the cooling capacity of the system in either the undercharge or full charge condition, the specific cooling capacity of the undercharge system, the useful work of the compressor, and the maximum pressure of the refrigerant increase. The increase in room temperature decreases the density of the refrigerant at the inlet and outlet of the capillary tube, the mass of the refrigerant in the capillary tube, the refrigerant subcooling at the inlet of the capillary tube, the maximum velocity of the refrigerant and the coefficient of performance. In addition, the increase in room temperature at overcharge condition causes an increase in the mass flow rate, cooling capacity and specific cooling capacity to a maximum value followed by their decrease. The most important difference between a portable air-conditioner and a non-portable system is the increase in cooling capacity with an increase in room temperature in full charge condition. Nomenclature: A : cross-sectional area of pipe (m2) CoP : coefficient of performance h : enthalpy (kJ/kg) k : specific heat ratio 푚̇ : mass flow rate (kg s-1) 푄̇ : heat rate (kW) R : gas constant SC : specific charge (W/g) U : velocity (m s-1) 푊̇ : power (kW) 푤 : specific work (kJ/kg) ρ : density (kg m-3) Subscript: 1 : compressor inlet 2 : condenser inlet 3 : capillary tube inlet 4 : evaporator inlet comp : compressor cool : cooling p : pipe r : refrigerant 1 s : isentropic 1. Introduction The use of hazardous synthetic refrigerants such as R12 and R22 is scheduled to be phased out due to their contribution to global warming and ozone depletion. Hydrocarbon refrigerants have zero effect on the ozone layer and a negligible effect on global warming (Oberthur et al., 1997), and are proposed to replace synthetic refrigerants. There are many recent published studies examining the performance of refrigeration and air conditioning systems using hydrocarbon refrigerants. One of the focus areas of these studies is the assessment of the performance of different systems at different ambient temperatures. Previous studies have not addressed the effect of ambient temperature on portable air-conditioners in which the temperature of the air surrounding the condenser and evaporator are the same. This research aims to narrow the gap in the literature with an empirical approach. It should be noted that in the case of portable air-conditioners, the condenser and evaporator are both located in the room subject to cooling. Therefore, the term “room temperature” refers to the temperature of air entering the condenser and evaporator, and differs from the outside temperature. The room temperature depends on the cooling capacity of the air-conditioner, ambient temperature, size of the room, wall thickness and material type, and many other parameters affecting heat transfer. In this research, the effect of room temperature on the temperature and density of the refrigerant, the degree of subcooling, the maximum velocity of the refrigerant, the mass flow rate of refrigerant, the cooling capacity of the air-conditioner, the specific cooling capacity, the work of the compressor, the coefficient of performance and the maximum pressure of refrigerant have been assessed. 2. Literature review Previous studies show that a change in ambient temperature has a significant impact on the performance of refrigeration and air conditioning systems. It was found that an increase inthe temperature of the air adjacent to the evaporator, not only increases the refrigerant temperature in the evaporator (Fatouh et al., 2010), but also increases the condensing temperature (Fernando et al.,2004). Corberán et al. (2011),in their research with propane as the refrigerant, found that the lower the source temperature(evaporator temperature), the lower the density of the refrigerant in the evaporator under the same refrigerant charge. The increase in density at higher ambient temperatures is due to the increase in condensing and evaporating pressures (Herbert-Raj et al.,2011, Teng et al., 2012 , Kim et al., 2012, and Kim et al., 2014). Choi et al. (2002), using R22 in their research, showed that the degree of subcooling decreases with the increase in ambient temperature. Nilpueng et al.(2011) reported that increasing ambient temperature and keeping the evaporator temperature constant, increases the pressure difference across the short capillary tube, which in turn increases the velocity of the refrigerant. The rise in ambient temperature has a significant impact on the refrigerant mass flow rate. Fatouh et al (2010) found that, as the temperature of the air surrounding the evaporator increases, the 2 condenser temperature and the mass flow rate increase. They concluded that the increase inthe mass flow rate is due to the increase in vapor density of the refrigerant. Choi et al. (2002) reported that the mass flow rate of the refrigerant increases with the increasing temperature of water used to cool the condenser. The increase in the mass flow rate is mainly due to the increase in the pressure difference across the capillary tube. Two separate studies by Rodrigez (1995) and Farzad (1990)also concluded that the increase in ambient temperature increases the mass flow rate. The drop of heat source temperature and maintaining the condenser temperature decrease the evaporation pressure, which results in an increase in the pressure difference across the short-tube orifice and leads to an increase in the refrigerant mass flow rate (Nilpueng et al., 2011). The cooling capacity of non-portable systems is affected by ambient temperature. Farzad (1990), in research using an air conditioner filled with R22, found that at full charge and overcharge conditions, the cooling capacity of his air conditioning system decreased with the increase in ambient temperature which contrasted with the undercharge condition. Rodriguez (1995), in research using R22 refrigerant, found that the cooling capacity of the system is highest when the outdoor temperature is the lowest. Choi et al. (2002), using a 3.5 kW heat pump filled with R22, found a similar result. In their research, the temperature of water entering the evaporator was maintained at a constant temperature of 24°C, while the temperature of the condenser cooling water was raised from 30°C to 42°Cwith an interval of 4°C. Martinez-Galvan et al. (2011), in a research using a 16 kW propane chiller prototype found a decrease in the cooling capacity with the increase in ambient temperature. They maintained the temperature of water entering the evaporator at12°C, and raised the temperature of cooling water entering the condenser from 25°C to 40°C with an interval of 5°C. A similar result was found by Corberán et al. (2011) who used a 16 kW propane chiller prototype and the same temperature range as in the work of Martinez- Galvan et al. (2011). Similar results were also found by (Palmiter et al., 2011). Two studies by Choi et al. (2002) and Wu et al. (2012) concluded that the increase in the compressor power is due to the rise in outdoor temperature. Farzad (1990) found that the increment of power at a lower refrigerant charge is higher than that at a higher refrigerant charge. Many studies reported the decrease of coefficient of performance with the increase in ambient temperature, regardless of the refrigerant charge level (Choi et al., 2002, Martinez-Galvan et al.; 2011; Corberán et al., 2011;Kimet al., 2012; Kim et al., 2014). This result can be explained by the decrease in the cooling capacity and the increase in the compressor work as ambient temperature increases. However, Kim et al. (2014) found that the coefficient of performance increases with the increase in source temperature while maintaining the condenser temperature. 3. Methodology and instrumentation This study experimentally investigates the effect of ambient temperature on the performance of a portable propane air conditioner. The normal charge of the system is 300 grams of propane. Previous studies show that the impact of ambient temperature could be different at different 3 refrigerant charge levels. Therefore, the experiments were carried out at three refrigerant charge levels of 263.10 grams (-12.3%, undercharge), 302.93 grams (+0.98% overcharge, assumed to be normal charge), and 390 grams (+30%, overcharge). The experiments were performed at six ambient temperatures ranging from20°C to 35°C with an interval of3°C. The air-conditioner was placed in a tent, and air temperature was controlled within ±0.5°C of the desired value using an electrical heater. The air conditioner is supplied by a flexible duct which vents the warm air from the condenser to the outside. The time required to reach a steady state condition in each experiment depended on the room temperature and desired temperature, but was usually in the order of two hours. However, due to unavoidable changes of ambient temperature during the experiments, it was necessary to open/close the tent windows to approach or maintain the desired temperature.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages19 Page
-
File Size-