Simics* Model Library for Eagle Stream Simulation Environment Release Notes May 2020 Revision V0.6.00 Intel Confidential Notice: This document contains information on products in the design phase of development. The information here is subject to change without notice. Do not finalize a design with this information. Intel technologies’ features and benefits depend on system configuration and may require enabled hardware, software, or service activation. Learn more at intel.com, or from the OEM or retailer. No computer system can be absolutely secure. Intel does not assume any liability for lost or stolen data or systems or any damages resulting from such losses. You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein. You agree to grant Intel a non-exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed herein. No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document. The products described may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. This document contains information on products, services and/or processes in development. All information provided here is subject to change without notice. Contact your Intel representative to obtain the latest Intel product specifications and roadmaps. Intel disclaims all express and implied warranties, including without limitation, the implied warranties of merchantability, fitness for a particular purpose, and non-infringement, as well as any warranty arising from course of performance, course of dealing, or usage in trade. Warning: Altering PC clock or memory frequency and/or voltage may (i) reduce system stability and use life of the system, memory and processor; (ii) cause the processor and other system components to fail; (iii) cause reductions in system performance; (iv) cause additional heat or other damage; and (v) affect system data integrity. Intel assumes no responsibility that the memory, included if used with altered clock frequencies and/or voltages, will be fit for any particular purpose. Check with memory manufacturer for warranty and additional details. Tests document performance of components on a particular test, in specific systems. Differences in hardware, software, or configuration will affect actual performance. Consult other sources of information to evaluate performance as you consider your purchase. For more complete information about performance and benchmark results, visit http://www.intel.com/performance. Results have been estimated or simulated using internal Intel analysis or architecture simulation or modeling, and provided to you for informational purposes. Any differences in your system hardware, software or configuration may affect your actual performance. Intel does not control or audit third-party benchmark data or the web sites referenced in this document. You should visit the referenced web site and confirm whether referenced data are accurate. Copies of documents which have an order number and are referenced in this document may be obtained by calling 1-800-548- 4725 or by visiting www.intel.com/design/literature.htm. Intel, the Intel logo, and Xeon are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others. Copyright © 2020, Intel Corporation. All rights reserved. 2 Revision: V0.6.00 Intel Confidential Simics® Software Transition Overview Simics Software, Version 6 Transition Sept. 27, 2019 – Dec. 31, 2019 • Transition period of 3 months during Q4’19; during this period, Simics software, version 5 (Python* 2.7) will continue to be supported with bug fixes, but will not include the latest functional and security updates. Users should update to Simics software, version 6 (Python 3.7). • Simics software, version 5 (Python 2.7) will no longer be supported or available after December 31, 2019. • No new Simics software, version 5 Base and Eclipse packages will be released after Q3’19. • We recommend users upgrade their Python scripts to version 3.7 to align with the Simics software, version 6 update. Simics Software, Version 6 Security Updates • Simics software, version 6 has been updated to include functional and security updates and is targeted for release on Sept. 27, 2019. • Simics software, version 5 does not include the latest functional and security updates. Customers should update to Simics software, version 6 as it becomes available. • Simics software, version 5: all versions are provided as-is and will no longer be available after Dec. 31, 2019. This version will not be supported with any additional functional, security or other updates. Intel recommends that users of Simics software, version 5 uninstall and discontinue use as soon as possible and upgrade to the latest version of Simics software version 6 or later. Simics software, version 5 does not include the latest functional and security updates. Simics software, Version 6 is targeted to be released on Sept 27th, 2019 and will include additional functional and security updates. Customers should update to the latest version as it becomes available. Simics software, version 6 has been updated to include functional and security updates. Users should update to the latest version. Revision: V0.6.00 3 Intel Confidential Contents 1.0 Simics* Model Library for Eagle Stream Features ........................................ 6 1.1 General Feature Summary ...................................................................... 6 1.2 Hardware and Software Requirements ...................................................... 6 1.3 Pre-Requisites ....................................................................................... 7 1.4 Simics Download Instructions .................................................................. 7 1.5 Windows Installation Instructions ............................................................. 7 1.6 DBGHelp Installation for Windows ............................................................ 8 1.7 Linux Installation Instructions .................................................................. 8 2.0 Configuration and Simulation with Simics .................................................. 10 2.1 Set Up Simics Workspace ...................................................................... 10 2.2 Sample Validation BIOS ........................................................................ 10 2.3 Simulating with Simics .......................................................................... 11 2.3.1 Windows .................................................................................. 11 2.3.2 Linux ....................................................................................... 14 2.4 Simics target Scripts ............................................................................ 14 2.5 OS Boot Times ..................................................................................... 14 3.0 Support and Issue Management and Documentation ................................. 15 3.1 Help ................................................................................................... 15 3.2 Issue support ...................................................................................... 15 3.3 Documentation .................................................................................... 16 3.4 New Features and Bugs Fixed ................................................................ 17 3.5 Limitations and Known Issues ................................................................ 18 Figures Figure 1. Windows Installers ................................................................................. 8 Figure 2. Starting Simics Simulation .................................................................... 12 Figure 3. Choosing Script ................................................................................... 13 Figure 4. Simics Windows Once Script Loads ......................................................... 13 Figure 5. Submitting Simics IPS Case .................................................................. 16 Tables Table 1. Requirements ........................................................................................ 6 Table 2 Decryption Keys for Package 1000 and 7921 ............................................. 7 Table 3 Simics Releases vs BIOS BKC’s .............................................................. 10 Table 4 OS boot times ..................................................................................... 14 4 Revision: V0.6.00 Intel Confidential Revision History Revision Number Description Date V0.3.00 Initial release of the document. June 2019 V0.3.01 Edited sections 1.4, 2.2 and 3.4 July 2019 Removed section “2.3 Sample Operating System Images” as it is not applicable anymore. V0.3.02 Edited sections 1.4, 1.5, 1.7, 2.2 and 3.4 August 2019 V0.3.03 Edited sections 1.4, 2.2 and 3.4 September 2019 V0.3.04 Edited sections 1.4, 1.5, 1.7, 2.2, 3.4 and 3.5 September 2019 V0.5.00 Edited sections 1.5, 2.2 and 3.4 November 2019 V0.5.01 Edited sections 1.4, 1.5, 1.7, 2.2, 3.4 and 3.5 December 2019 V0.5.02 Edited sections 1.4, 1.7, 2.2. and 3.4 February 2020 V0.5.03 Edited sections 1.4, 2.2, 3.4 and 3.5 March 2020 V0.6.00 May 2020 § Revision: V0.6.00 5 Intel Confidential
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages19 Page
-
File Size-