Application of Multizone Hvac Control Using Wireless Sensor Networks and Actuating Vent Registers

Application of Multizone Hvac Control Using Wireless Sensor Networks and Actuating Vent Registers

APPLICATION OF MULTIZONE HVAC CONTROL USING WIRELESS SENSOR NETWORKS AND ACTUATING VENT REGISTERS William Watts Mike Koplow Andrew Redfern Paul Wright Graduate Student Graduate Student Research Associate Professor/Director Department of Mechanical Engineering, University of California, Berkeley Center for Information Technology Research in the Interest of Society, University of California, Berkeley ABSTRACT zone consists of the house area where the vents are Most residential heating, ventilating, and air fully open. Controlling the vent registers allowed conditioning (HVAC) systems are designed to treat for reduced zonification between rooms on the the home as a single zone. Single zone control same floor, and reduced stratification between the consists of one thermostat, in a central area of the upstairs and downstairs. Energy savings were house that controls the HVAC operation. In a shown when vents were closed to heat the control single zone system all of the vent registers are zones containing the bedrooms, or the office. open, distributing air into all areas of the house at once. Single zone control leads to wasted energy INTRODUCTION for two reasons – all rooms being conditioned Most residential heating, ventilating, and when they are not occupied, and conditioning air conditioning (HVAC) systems treat the house as occupied rooms, without maintaining them at a a single zone. The standard residential system is comfortable temperature for the occupants. constant air volume (CAV). This means that the Improved control of residential cooling and heating conditioned air is delivered to all vent registers in can be attained with a variable HVAC fan, duct, the house at a fixed proportion. The lack of finer and vent system. control over where conditioned air enters the house leads to zonification due to large temperature Existing single zone systems are expensive to differences between rooms on the same floor, and retrofit with the above mentioned features. Current stratification due to large temperature differences techniques require replacing major components in between rooms on different floors. the HVAC system which are both costly and time consuming, invading the user’s home. An Energy is often wasted conditioning a alternative to the extensive retrofit is detailed in zone of the house that is not occupied. Energy is this work. also wasted when an occupied room is conditioned to a temperature that is not comfortable. Multi- The experiments in this paper implement an zone control over which areas are heated and automated vent louver system to solve two cooled is needed to solve this problem. A variable problems in heating homes: the problem of air volume (VAV) system would allow for temperature stratification between floors and increased air flow into some areas of the house zonification between rooms, and the energy wasted while decreasing air flow to others. to heat in unoccupied areas of the home. State of the art multiple zone wireless This paper considers the application of HVAC control systems are available for replacing the standard vents in each room with commercial buildings. Discharge-air-regulation- wireless controlled louvered vents. These vents technique (DART), implements wireless mesh allow for simpler, more cost effective retrofits networking to measure temperature and control which are also less invasive to the end user’s home. HVAC fan speed [1]. Millennial Net, and Siemens The experiments in this paper implement an APOGEE offer wireless solutions to building automated vent louver system to reduce the energy controls and measurement [2,3]. The latter systems wasted to heat unoccupied areas of the home. utilize wireless temperature nodes but the VAV controls are wired to the thermostat control system. The test house in these experiments was a two story home. Wireless sensor-actuator Multiple zone solutions often require networks were used to automate the task of closing expensive retrofits. This paper focuses on a more off vent registers while maintaining the appropriate cost effective alternative by automating vent temperature set point in a control zone. A control registers rather than altering the entire HVAC system. With wirelessly controlled louvers, a low Wirelessly controlled vent louvers are a cost software based home controller would be able component of an automated multiple sensor, and to enable increased comfort and energy savings by multiple actuator system that can be controlled closing off vents to areas where conditioning is not locally within the residence, or remotely over the needed [4]. internet [7]. An embedded server is outfitted with a wireless base station that is able to interact with Most gains for energy management in the wireless network by receiving and sending residential buildings will come from smarter use of message. The server contains a database that HVAC systems. HVAC systems comprise over receives and stores sensor data, and actuator state 50% of the total residential energy demand. data that is accessible by a Java controller operates Reductions in residential energy demand due to in the server unit. The Java controller is able to optimized automation of HVAC systems would send out messages to the vent and HVAC reduce both peak and base energy load, in most actuators. The message for the vent actuators in regions [5,6]. open or close and the message for the HVAC actuator is heat, cool, fan, or off. While this paper focuses on the application of the multizone solutions for The following Section describes the residential systems, the technology is also system hardware and software setup. A description applicable to commercial buildings as well. As is given of the automated vent louvers, the wireless with residential systems, it is common to control HVAC actuator, the wireless temperature sensors, several rooms of a building with a single and the embedded server-controller unit. Within thermostat sensor. Previous researchers have that section the system software is described investigated the simulation of applying multiple including the software that drives the sensors and temperature sensors in the building environment actuators, the software that controls the actuators, [7]. Simulations show an increase in user comfort and the database software setup. The subsequent by using targeted comfort control strategies. Section describes the reliability tests of the hardware and software system. A two story house in Danville, CA was retrofitted to test and verify the proposed multi- Section 4 describes air handler fan energy zone retrofit. All of the vents in the house were demand measurements for each vent configuration, replaced with wirelessly controlled vent louvers. and the variable air flow measurements in each The thermostat disaggregated into several pieces: zone for each vent configuration. Accurate an actuator switching on an off the heating, measurement of air flow for each vent cooling, or fan, a software controller that was configuration was needed to prove the running on an embedded server, and temperature effectiveness of the vent retrofit and to better sensors that were distributed throughout the house. understand the energy demand measurements. The residence is divided into four Control Section 5 describes the procedure used to Zones. Zone 1 contains the downstairs living, measure energy demand for heating a particular dining, and kitchen area. Zone 2 contains the zone. Section 6 shows the preliminary results from bathrooms and laundry room. Zone 3 is all of the zone control with the automated vent registers. bedrooms, and Zone 4 is the office. Trends in the experiments indicate that closing registers can lead to less system on-time which will In this paper a Control Zone is defined as yield energy savings. the area of the house where all vents are open, while all other vents in the house are closed. The EXPERIMENTAL PLATFORM temperature of a Control Zone is determined by the The experiments were automated with the average temperature of the temperature sensors use of wireless sensors and actuators. An within the open vent area. The HVAC controller embedded server-controller unit allowed remote determines if a Control Zone has reached the set monitoring and scheduling of experiments. There point based on the average temperature. Building were four key pieces of hardware used in the simulations in literature show that optimal HVAC experiments: the Tmote wireless platform, the energy savings are achieved when taking the NSLU2 embedded server unit, the wirelessly average of distributed temperature sensors within controlled vent louver, and the wirelessly the area being conditioned [7]. controlled HVAC actuator. The software is divided into three components: the user interface, controller, and TinyOS sensor-actuator network software. Hardware The sensor and actuator wireless devices used in these experiments were the Tmote (Telosb) platform from the company Moteiv, shown in Figure 1. The Telos mote operates from a TI MSP430 microprocessor that features eight 12 bit analog to digital converters (ADC) and four digital input output converters. The mote communicates wirelessly with a Chipcon CC2420 transceiver that operates on 2.4GHz and is 802.15.4 compliant [8]. Figure 1: Tmote with full sensor suite: temperature, The Tmote onboard sensor suite has two humidity, photosynthetically active radiation, and components: a digital based, self- calibrating total solar radiation. CMOS temperature and humidity sensor, and an analog based light sensor capable of detecting The backbone of the system is the NSLU2 visible and infrared radiation. The temperature and Linksys storage link USB server. NSLU2-Linux humidity sensors are manufactured by Sensirion, (SLUG) is installed on the device in place of the models SH11 and SH15. The light sensors consist Linksys operating system configuration. A picture of a thermally sensitive radiation sensor (TSR) and of the NSLU2 is shown in Figure 2. The controller a photosynthetic active radiation sensor, unit had enough processing power to control the manufactured by Hamamatsu. The light sensors vent and HVAC actuators. The unit was also able connect to two ADC ports. to store and serve sensor data and actuator state data.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    9 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us