INSTALLATION, OPERATION, MAINTENANCE AND TROUBLESHOOTING WARNING: Raritan Engineering Company, Inc. recommends that a qualified technician install, troubleshoot and repair this product. Equipment damage, injury to personnel or death could result from improper installation. Raritan Engineering Company, Inc. accepts no responsibility or liability from damage to equipment, or injury or death to personnel that may result from improper installation of this product. WARNING: Refrigeration Equipment contains refrigerant fluids under very HIGH PRESSURE. Danger of sudden pressure release may cause injury, death or severe frostbite resulting from not following instructions. CAUTIONS:DO NOT plug a 120 volt unit into a 240 volt power source. DO NOT plug a 240 volt unit into a 120 volt power source. DO NOT use a transformer to step down 240 volt 50 HZ power supply to 120 volt. Equipment designed for 60 HZ may run slow on 50 HZ, resulting in inferior operation and possible overheating of the motor(s). WARNING: This device is not ignition protected. DO NOT install in compartments containing gasoline tanks or in areas in which ignition protected equipment is required. INTRODUCTION OPERATION Model 84 and 85 Icer-ettes are CFC-Free automatic The Icer-ette's on-off switch is just beneath the door. A icemakers designed and manufactured especially for unit begins to produce ice within 60 minutes after start- the marine environment. They produce up to 22 lbs up. Ice production stops automatically when the bucket (10kg) of crescent shaped ice per day and can store 11 is full enough to interfere with the wire shut-off arm. The lbs (5kg). Model 84 is designed for installations unit should not be turned "off" with the door closed and where less than counter height is available and the 85 ice or water inside. is designed for counter height installaions. Each NOTES: model has a flush mount option which prevents the 1. Due to fast freezing, ice cubes may appear door from extending beyond the cabinets. Installation "cloudy". This is trapped air in the water and and maintenance are simple because no drain is does not affect the taste or quality of the ice. required and the thermostat is fixed; never needing adjustment. 2. "Hollow" ice cubes may result from fast- freezing under certain climatic conditions such as high humidity, etc. and is not an indication of a problem with the icemaker. MODEL 85 MODEL 84 1 MAINTENANCE √ Periodically vacuum dust and dirt from the condenser, located behind the grille at the bottom front of the unit. √ Regularly inspect plumbing connections to insure that no leaks are present. When necessary, defrost and thoroughly clean the inside of the unit with mild soap and water. Do not use electrical heating devices, sharp or pointed tools when defrosting. When defrosting or leaving the unit turned off, prop and leave the door open using door prop. This allows air to dry the inside of the cabinet, reducing the chance for mildew and damage to the mold mechanism's components. WINTERIZING WARNING: Disconnect power at source MAINTENANCE before working on the unit. Do not winterize this unit with ANY type of anti-freeze; damage to the mold coating will occur, invalidating product's Limited Warranty and creating potential health hazard. 1. Shut off the water supply to the unit. 2. Disconnect as follows: Model 85: Disconnect water supply connector behind front grille at solenoid valve (garden hose connector). Remove white plastic tubing and nut from bottom of solenoid valve. Model 84: Disconnect the in-line water supply connector behind the front grille. START-UP 3. Turn power on. Allow unit to run for an hour. Turn on water, check for leaks and then turn on power. Remove any cubes that may have been ejected Turn on switch (located just below Icer-ette door). Fan during this period. Turn off power and prop and compressor will normally turn on immediately, door open to allow the inside to defrost. After resulting in air circulation through the grille and a faint it has defrosted, wipe it dry and leave door hum from the compressor. If machine was shut off while open using door prop. in ice harvesting cycle, it will have to complete the cycle before compressor and fan turn on (approximately 5 minutes). Interior temperature will drop below freezing. RECOMMISSIONING First harvest of ice should occur within 60 minutes of Connect water supply lines, turn on water, check for start-up. After lines are purged of air, normal harvesting leaks, then restore power to the unit. After initial cool and refilling occur every 40 minutes or less, under normal down of 45-60 minutes, the unit will cycle conditions. approximately every 40 minutes. MOUNTING 2 INSTALLATION Required Cabinet Opening: FIG. #1 Ventilation Model 84: 14 3/8" W x 18 1/2"H Model 85 Model 85: 14 3/8" W x 24 5/8"H WARNING: If rubber feet are removed from the bottom of 85 series units, the mounting screws Air path for exhaust and fresh air intake must be reinstalled into the bottom of the cabinet must be unrestricted! to avoid damage to components mounted to the Recirculation between fresh air intake and base pan. exhaust air must be If unit is to be built-in, 3/4" (2cm) or more must be prevented. allowed behind the unit for water line and plug clearance for proper operation. Built-in units are designed for zero clearance at the top and each side of the unit. Fan-forced condenser cooling is used. OUT IN This requires air circulation through lower section of unit (see Fig. #1). If Icer-ette is to be installed behind closed doors, contact Raritan Technical Support. Model 84 CAUTION: Any restriction of airflow or IN ventilation will disrupt normal operation of the OUT unit, resulting in damage to components and BOTTOM FLANGE INSTALALTION voids warranty. MODEL 85/84B Unit must sit on a secure level surface. Mounting 1. Loosen top two grille flange must NOT be used to support the unit's screws weight. 2. Remove bottom two When installing the unit it should be noted that some grille screws servicing requires access to the rear of the unit and 3. Place bottom trim that the unit must be readily removable should flange between grille servicing be necessary. and cabinet. When mounting unit within cabinetry, make sure 4. Align holes and install that the door has the desired range of motion. All bottom grille screws doors are hinged on the right (facing the unit) but may be reversed in the field. MODEL 85E PLUMBING Once unit is installed in cabinet A minimum of 22 P.S.I. (152kPa) is required for 1. Attach trim spacer to bottom flange proper operation of the water valve (see #26, page 4). 2. Slide bottom flange in place. When plumbing Icer-ette, 18" (45cm) of water line 3. Secure with 2 screws. extends from the back with a 1/4" plastic female compression fitting. Drains are not required; just a water supply. WIRING WARNING: HAZARD OF ELECTRIC SHOCK - Never use extension cords or plug adapters to power unit. Never remove the ground prong from the plug. Power Requirements: 120 volts 60 HZ AC (alternating current); a three-wire cord with grounded plug is supplied, OR: 240 volts 50 HZ AC (alternating current), supplied with Euro-plug. 3 Exploded View of Model 85 Icer-ette Exploded View of Model 84 Icer-ette EXPLODED VIEW Exploded view of Item #21 1 3 4 2 Wiring Diagram LINE VOLTAGE Raritan Icer-ette Series 84 and 85 WHITE GREEN BLACK (120 VAC) BLUE GREEN/YELLOW BROWN (240 VAC) POWER COMPRESSOR RELAY SWITCH AND OVERLOAD BLACK BLACK WHITE FUSE (240 V ONLY) LINKS ICE MAKER MODULE COMPRESSOR ORANGE GREEN WHITE COLD CONTROL BROWN BLACK OR WHITE RELAY WHITE 2 WATER 7 FAN VALVE A B BLACK WHITE 4 Model 84 Model 85 PARTS LIST Intem Descriptio Model 84 Model 85 220V 240V 1sWiring Harnes I044 I44422 I04 I4422 2)Module Assy. (628366 I034M-1 I134M22 I034M- I34M22 3tThermosta IT34T IT34 IT34 I34 4tIcemaker Mold w/thermosta I034MH IH34MH22 I034M I34MH22 1.1 Handle Latch Assy I5M135 I5M13 I5M13 IM13 1t2 Door Gaske I9M89 I9M8 I9M8 IM8 Nylon Snap Bushing - Black I2101 I2101 I2101 I2101 13 Nylon Snap Bushing - White I21 I21 I21 I21 S/S Door Assy. IM215W IM215W IM215W IM215W White laminate Door Assy. IM216W IM216W IM216W IM216W 14 Black Laminate Door Assy. IM217W IM217W IM217W IM217W Neutral White Laminate Door Assy. IM218W IM218W IM218W IM218W 1h5 On-Off Rocker switc IS37S IS37 IS37 I37 8-32 x 1/2 hex head type F 18-8 s/s 16 I373 I37 I37 I7 screws 1e7 Grill I1M9S01 I1M9S0 I1M90 IM90 Top screw 1/4-28 x 1/2 F181 F181 F181 F181 18 Bottom screw 1/4-28 x 5/8 hex head CH51 CH51 CH51 CH51 1m9 Hinge Set Top & Botto IWM13W IWM13 IWM13 IM13 2t0 Ice Bucke I090 I09 I09 I9 2r1 Ice Make IW34W IW34220 IW34 I34220 2r2 Ice Maker Front Cove IA34A IA34 IA34 I34 2r3 Relay w/overload protecto I21806-1 I11806- I21806- I1086- 2g4 Water line tubin IW93SW I393S I39 I9 2e6 Water Valv I034B IB34B22 I034 I34B22 2)7 Compressor (includes #40 IW1800A-1W IW1800A-2 IW1800A-1 I1800A-2 2d8 Power Cor I041 I14122 I04 I4122 2e9 Service valve w/tub I1101 I110 I110 I10 4r0 Drie I130A01 I130A0 I130A0 I30A0 4.1 Motor and/or Blower Assy I028 I52822 I02 I2522 4l2 C old C ontro IA33A IA33 IA33 I33 4y3 R ela I052 I25222 I05 I5222 BI Flange Part numbers Flush Mount Flange Part numbers IM9904 Top Flange - Model 85E, 85EH, 84E, 84EH IM9901 Top Flange - Model Bottom Flange model 85E, 85EH 85B, 85BH, 84B, 84BH IM9903 sides - Model 85B IM9906 sides - Model 85E IM9903H sides w/holes - Model 85BH IM9906H sides w/holes - Model 85EH IM99S03 sides - Model 84B IM99S06 sides - Model 84E IM99S03H sides w/holes - Model 84BH IM99S06H sides w/holes - Model 85EH IM9902 Bottom Flange - Model 85B, 85BH, 84B, 84BH 5 BE SURE TO READ THE FOLLOWING PARAGRAPH BEFORE ATTEMPTING ANY TROUBLESHOOTING OR REPAIR OF ICER-ETTE UNITS.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages8 Page
-
File Size-