Drug Testing - AHS

Drug Testing - AHS

What Does the Drug Test Tell Us QUALITATIVE TOXICOLOGY TESTING for CLINICAL MANAGEMENT of the PATIENT Background • The qualitative drug test is often referred to as the “drug screen” - a misnomer • Testing performed using: – Immunoassay – GC/MS or LC/MS/MS confirmation techniques 2 1 Immunoassay – Initial Testing • Antigen-Antibody reactions • Refers to instrument based and non-instrument based techniques • Designed to detect a broad class of drugs • Cross-reactivity (the ability to detect a drug) dependent on reagent chemistry and devices used • Limited in scope (i.e. limited number of assays available) • Prone to false negatives and false positives 3 Confirmation Testing • Uses GC/MS or LC/MS/MS techniques • Confirms immunoassay result or initial testing for drugs in which no immunoassay available. • More resource driven than immunoassay • Provides specificity that cannot be achieved with immunoassay 4 2 Amphetamines (CEDIA) • Designed to detect methamphetamine, amphetamine and MDMA (same or different assays) • Will potentially detect other amphetamine like drugs PMMA/PMA pseudoephedrine/ephedrine phentermine phenylpropanolamine mephentermine • Will detect non-amphetamine like drugs bupropion trifluoromethylphenylpiperazine (TFMPP) trazodone m-CPP (trazadone metabolite/BZP analog) ranitidine phenelzine breakdown fenofibrate 5 Cocaine Metabolite (KIMS) • Tends to be specific for cocaine metabolite (benzoylecgonine) • Cocaine can be used in hospital type procedures – Eye surgery – Nasal surgery • Cutting Agents – levamisole, diltiazem, hydroxyzine, phenacetin, benzocaine 6 3 Cocaine Cut in Alberta* 40.0% 34.8% 35.0% 33.3% 28.4% 30.0% 27.4% 24.1% Levamisole 25.0% Benzocaine 20.0% 15.5% Phenacetin 15.0% 9.8% Diltiazem 10.0% 6.9% 5.0% 3.0% 851 819 90 966 448 201934 262 646 0.0% Apr/09 ‐ Mar/10 Apr/10 ‐ Mar/11 Apr/11 ‐ Mar/12 *Data Courtesy Controlled Substances and Tobacco Directorate, Health Canada 7 Cocaine Pharmaceutical Cutting Agents UAH Percent of Cocaine Confirmed Specimens Containing Cutting Agents 80.0% 69.5% 70.0% 63.0% 60.0% 58.6% 50.0% 2010 40.0% 2011 2012 30.0% 25.0% 20.0% 18.3% 10.0% 4.0% 5.0% 1.5% 1.4% 0.0% Levamisole Phenacetin Diltiazem 8 4 Opiates (KIMS) • Designed to pick up morphine and codeine • Will detect other opioids but not as well – hydrocodone – hydromorphone • Does not detect: – methadone/methadone metabolite (specific immunoassay) – buprenorphine (detected using LC/MS/MS) • Detects oxycodone poorly (specific immunoassay) • Ofloxacin and rifampin can cause a false positive 9 Benzodiazepines (KIMS) • Tends to be fairly specific for benzodiazepines • Some benzodiazepines more detectable than others • Metabolite cross-reactivity can be poor • Oxaprozin (Daypro) can cause a false positive • Cross-reactivity table 10 5 Generic Name Trade Name 300 ng/mL Equivalent % Cross-Reactivity Clobazam 382 79 Chlordiazepoxide Librium 486 62 Desmethylchlordiazepoxide 517 58 Clonazepam Klonopin 445 67 7-aminoclonazepam 489 61 Flunitrazepam Rohypnol 424 71 7-aminoflunitrazepam 333 90 desmethylflunitrazepam 395 76 3-hydroxyflunitrazepam 584 51 Flurazepam Dalmane 490 61 Hydroxyethylflurazepam 347 87 didesethylflurazepam 423 71 Desalkylflurazepam 323 93 Lorazepam Ativan 487 62 Lorazepam glucuronide >20,000 1.1 Midazolam Versed 467 64 -hydroxymidazolam 431 70 Temazepam Restoril 409 73 Temazepam Glucuronide >20.000 1.0 Triazolam Halcion 352 85 -hydroxytriazolam 377 80 4-hydroxytriazolam 385 78 11 Marijuana Metabolite • Designed to detect the marijuana metabolite - 11-nor- 9-tetrahydrocannabinol-9-carboxylic acid but will detect other metabolites • Historically assay was quite robust • New techniques saw emergence of false positives: – pantoprazole / Pantoloc (for acid-reflux) and POCT devices – efavirenz / Sustiva (anti-viral) and CEDIA chemistry • Passive exposure • Baby wash products vs metabolites normally occurring in neonates 12 6 GC/MS or LC/MS/MS Confirmation Testing RECEIVE URINE • More resource driven than the immunoassay SAMPLE PREPARATION - EXTRACTION GC/MS (2 mL to 10 uL) • Gives a fingerprint of drug LC/MS/MS (1 mL to 250 uL) based on retention time and fragmentation pattern INJECTION ON GC/MS or LC/MS/MS • Identify specific compounds SEPARATION in GC or LC (Retention Time) • Considered confirmation tests FRAGMENTATION in MS (Library Match/SIM or MRM) 13 General Retention Times • Amphetamines up to 4 days • MDMA (Ecstasy) up to 4 days • Marijuana Metabolite up to 30 days (chronic vs occasional) • Cocaine metabolite up to 4 days • Opiates up to 3 days • Heroin Metabolite less than 1 day • Barbiturates days to weeks • Benzodiazepines days to weeks • Methadone up to 3 days • Alcohol less than 1 day 14 7 The STAT Drug Test • Qualitative toxicology testing is rarely of any value in emergent situations for the acute management of patients for several reasons: – It does not confirm or rule out significant poisoning. – It almost never provides information that leads to a meaningful change in acute medical management. – Countless drugs contribute to common clinical symptoms seen in an emergency department that are not tested for/detectable by immunoassay screening tests. – The testing is not specific (i.e. there are multiple false positives, which then require explanation and perhaps needless investigations). – A positive test does not mean that this is what is contributing to the patient's symptoms. • NOT diagnostic – cannot be used to diagnose poisoning 15 Qualitative Urine Drug Testing - AHS • Cannot be used as a measure of impairment • Not for employment related purposes • Not for insurance purposes • Not for drug facilitated assault • Not for accident investigation/impaired driving • Not for apprehending children under child and family services authorities • Use for the CLINICAL management of patients – determining compliance challenging 16 8 Contact Information - Toxicologists • Dr. Penny Colbourne 780-407-4729 • Dr. Don LeGatt 780-407-8444 • For acute management of the poisoned patient contact PADIS 1-800-332-1414 17 9.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    9 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us