Frankfurt Iil Overview

Frankfurt Iil Overview

Frankfurt IIl CyrusOne Data Center Willhelm Fay Strasse Frankfurt am Main Germany Latitude: 50.128098 Longitude: 8.582833 CyrusOne Frankfurt IIl is a brand-new purpose-built data center offering cloud providers, systems integrators and multinational corporations customised, secure and resilient data center solutions within a key business hub. The facility is strategically located in Sossenheim, the preferred location for data centers in Frankfurt, Germany’s “Digital City”. It sits just 500 meters from CyrusOne Frankfurt l and Frankfurt ll, delivering Overview 22 MW of IT power to 11,560 sq m (124,430 sq ft) of world-class technical • 22 MW of IT power delivered to 11,560 sq m (124,430 sq ft) of world-class technical space, with each data suite customised space within two attached, four storey, data centers to individual client specifications. • Active / Active 110 kV dual redundant power supplies with fully flexible IT power solutions • Connection to the European high voltage grid via two independent substations Frankfurt (separate from Frankfurt l and ll) 5 am Main Ost Eschborn Frankfurt am Main Mitte-Nord • Ultra-low PUE through the use of Indirect Adiabatic Air Cooling to each data hall 66 • Highly resilient, concurrently maintainable power and cooling to Tier III+ Bockenheim Sossenheim • Carrier neutral access and diverse fibre connectivity to active A&B Meet Me Rooms from 648 Frankfurt Frankfurt am Main West multiple telecommunication providers • Bespoke and scalable data halls Sachsenhausen-Nord • Multilayer industry-leading levels of physical and electronic security Schwanheim Frankfurt.. am Main Sud • Dedicated offices, buildroom and/or ancillary space adjacent to each hall 5 3 • Dedicated N+N electrical infrastructure to each data hall 3 • Secure managed delivery bays with 3 tonne goods lifts Frankfurt • 24/7 year round onsite support Airport CyrusOne Enterprise Data Centers | [email protected] | CyrusOne.com Frankfurt IIl Technical Specifications Building Energy Efficiency Building and Energy Management systems (BMS and EMS) • 11,560 sq m (124,430 sq ft) of technical space within two attached, • Ultra-low PUE through the use of Indirect Adiabatic Air Cooling • Power and building monitoring systems to provide alarms four storey, data centers to each data hall with free cooling capacity • Power surge management • Floor loading 12 kN per sq m • Scalable UPS capable of ECO and sequence modes • 24/7 year round on-site M&E engineers undertaking Planned • Delivery bay with access to two 3-tonne goods lifts • Variable speed drive adiabatic fans Preventative Maintenance (PPM) programmes • Bespoke and scalable data halls • ASHRAE T9 hall conditions • Real-time monitoring of electrical and mechanical systems • Dedicated offices, buildroom and/or ancillary space adjacent to • Air cooled plant rooms with variable speed fans Security each hall, built to your requirements • Rainwater recovery for reduced water usage • High security perimeter fence • On-site electric vehicle charging points Fire Detection and Suppression • External CCTV and Geoquip trembler wire to fence Power • Three-stage fire detection systems into data halls and UPS plant areas • Dual vehicle locks to site entrance with dual gates and physical • Operated with 22 MW of IT power • VESDA (Very Early Smoke Detection Apparatus) in data halls and UPS ram protection • Active / Active 110 kV dual redundant power supplies with fully plant rooms for early warning • 24/7 year round on-site security located in secure control room flexible IT power solutions • Fire detection in all rooms, ceiling return air plenums and in voids • Extensive CCTV and access control throughout the facility • Connection to the European high voltage grid via two independent as required • Progressive layers of security restrict access throughout the substations • Gas suppression to data halls and UPS rooms with dedicated bottles site and facility • N+N power solutions dedicated to each hall • Double knock approach gas suppression to all areas, single zone • Mantraps with biometric readers into data halls if required • Minimum N+N UPS with 10-minute battery back-up as standard activation Compliance (Operated to International Standards) • Fully rated N+1 MV back-up generators with 48-hour fuel autonomy • Fire detection and suppression systems interconnected to central BMS at full load, capable of continuous running • ISO 14001 Environmental Management • Re-fueling contracts in place to ensure timely replacement • ISO 27001 Information Security Management • All IT power metered and charged as consumed at dedicated • ISO 9001 Quality Management MV meters • ISO 50001 Energy Management Cooling • N+1 Indirect Adiabatic Air Cooling to each data hall resulting Typical in ultra-low PUE Cooling Cooling • Cooling infrastructure individually managed and linked to BMS Floor Plan • Independently regulated temperature and humidity to each space Power A Power A utilising hot aisle containment • A&B Power Supplies to cooling equipment for full redundancy Power A Power A (local ATS’s) Data Hall Data Hall • Highly resilient, concurrently maintainable power and cooling to Tier III+ Power B Power B • 1,300 mm return air plenum with 4,400 mm clear height in the data hall Connectivity Power B Power B • Carrier neutral access and diverse fibre connectivity to active Cooling Cooling A&B Meet Me Rooms from multiple telecommunication providers • Access to the world’s largest Internet Exchange DE-CIX Store Store • Diverse cable routing into facility to dual MMRs Offices Offices • Strict cable management policy Entrance Entrance CyrusOne Enterprise Data Centers | 2101 Cedar Springs Road | Suite 900 | Dallas, Texas 75201 USA [email protected] | CyrusOne.com.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us