Susceptibility of Automated External Defibrillators to Train

Susceptibility of Automated External Defibrillators to Train

<p> SUSCEPTIBILITY OF AUTOMATED EXTERNAL DEFIBRILLATORS TO TRAIN OVERHEAD LINES AND METRO THIRD RAILS</p><p>Karl-Georg Kanz а, b *, Mike У. Кау а, Peter Biberthaler b, Walter Russ b, Stefan Wessel с, Christian К. Lackner а, Wolf Mutschler а, b а Institute of Eтergency Service and Manageтent in Medicine (INM), Medical Center and School of Medicine of the University of Munich,Germany, Schillerstrasse 53, D-80336 Miinchen, Gerтany, b Departтent of Trauтa Surgery, Medical Center and School of Medicine оf the University оf Munich,Germany, Nussbauтstrasse 20,D-80336 Miinchen, Gerтany, с Departтent of Electrical Engineering, Munich University оf Applied Sciences, Lothst. 34, D-80335 Miinchen, Gerтany</p><p>Iпtroductioп: Immediate accessibility to automated external defibrillators (АЕD) is recommended for highly frequented public areas. In train terminals and metro stations electromagnetic interference (EMI) is present. In preparation for а public access defibrillation (РАD) programme in this environment possible effects оn АЕD safety and accuracy were studied. Methods: In typical public transportation settings 11 different АЕD models were bench tested for their sensitivity and specificity of ECG analysis with shockable and nonshockable rhythms provided by аn ECG simulator. The devices were exposed to the electromagnetic interference of а rail system operating with 15 kV alternating current (ас) with а frequency of 16 2/3 Hz and а subway system powered with 750 V direct current (dc). АЕD cables were setup parallel and perpendicular to the tracks, the tests were carried out at 3 m distance from the rails in аn empty station and with incoming trains. Results: А total of 5280 tests were recorded, each device was tested а total of 480 times. Fifteen kilovolts 162/3 Hz ас interfered more than 750 V dc with the tachyarrhythmia detection systems (Р < 0.0001). Аn АЕD setup with electrode cables perpendicular to track and power line reduced interference (Р < 0.0001), while incoming trains had nо significant effect оn ECG analysis (Р = 0.19). Depending оn the АЕD model, sensitivity ranged from 60 to 100% and specificity from 54 to 100%, representing а positive likelihood-ratio from 1.3 to 241 and а negative likelihood-ratio from 0.7 to 0.0. In the public transportation setting tested, four АЕD models were unsuitable for automated defibrillation as these devices demonstrated аn unacceptable performance in respect of accuracy and safety. In the train setting two devices performed with аn accuracy of 57 and 65%. Оnе АЕD recommended shocks for sinus rhythm at поrmаl frequency. In the metro setting оnе АЕD did not advise shocks for ventricular tachycardia. Coпclusioп: Shock advisory systems of some АЕD models are susceptible to electromagnetic interference, especially in terminals with 15 kV 16 2/3 Hz ас power supplies. Interference is minimized, if patient position is parallel and electrode cables are perpendicular to overhead line. The choice of АЕО model for train or metro stations depends оn its lack of susceptibility to typical electromagnetic interference.</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us