Discodad 641 Operating Instructions

Discodad 641 Operating Instructions

<p>DiscoDAD 641 Operating Instructions</p><p>Updated 01/05/2017 TJM 1. Enable DiscoDAD 641 in iLabs. 2. Open DI water, Spindle cooling water and nitrogen valves on the back wall .</p><p>Figure 1: Di water, Spindle water and N2 valves 3. Open front panel, turn key to turn system on and wait for the system to boot up indicated by the appearance of the Main Menu screen on the monitor.</p><p>4. Initialize system by pressing the on the front panel.</p><p>Updated 01/05/2017 TJM 5. Press the to bring up the Non-Contact Setup screen and then press to initiate setup. Setup completion is indicated by the Led above the setup key. If there is an </p><p> error, press the and redo the above procedure.</p><p>6. Turn on the spindle water by pressing . Let system warm up for at least 10 minutes.</p><p>7. Mount Sample on an 8” flat metal ring using the dicing tape.</p><p>8. On the main menu screen, press to enter manual operation screen. Use the cursor keys to select the Directory & Device data fields and enter the directory name and the device data no of the data file (created by authorized personnel) containing the cutting data. </p><p> Use the to access the alphanumeric keypad, remember to press the to disable</p><p> the alphanumeric pad.</p><p>9. Load sample on the chuck (fig. 3) and press the . The sample will be clamped held by the chuck vacuum. Close Shield. </p><p>10. In the manual operation screen , chose the cutting operation </p><p>Updated 01/05/2017 TJM a. selects the automatic cutting, this performs the cut in both direction </p><p> b. selects the semi-automatic cutting which performs the cut only in the selected direction.</p><p>11. After selecting the cutting operation , review cutting data by pressing </p><p>12. Press to enter manual alignment mode.</p><p>13. Chuck Table moves under the camera and the alignment screen is displayed on the monitor. It may be necessary to perform focus & light intensity adjustment. </p><p>It might be necessary to perform this adjustment in Low magnification; this can be done by </p><p> pressing to change the magnification.</p><p> a. Light intensity Adjustment</p><p> a.i. Press the key to enter the light adjustment screen </p><p> a.ii. Use the keypad controls to adjust the brightness ( Keypad definition listed at the bottom of the screen).</p><p> a.iii. Press the Key once done.</p><p> a.iv. Repeat process in High magnification.</p><p> b. Focus Adjustment </p><p> b.i. Press the key to enter the focus adjustment screen </p><p> b.ii. Use the keypad controls to adjust the focus (Key pad definition listed at the bottom of the screen)</p><p> b.iii. Press the key once done.</p><p>Updated 01/05/2017 TJM b.iv. Repeat process in High magnification</p><p>14. Theta Alignment Procedure:</p><p> a. It may be necessary to perform this in Low magnification first, then High magnification.</p><p> b. Use the Cursor keys(figure 4) to align the hairlines to the first point/feature on the </p><p> straight line on the sample, end alignment with the key </p><p> c. Press to perform theta alignment </p><p> d. Stage moves to the right, use cursor keys (figure 4) to align to the second point/ feature that is on the same straight line on the sample, end the alignment with the up key. Press</p><p> the key and theta alignment is automatically performed</p><p> e. Repeat procedure in High magnification </p><p>15. After theta alignment, Channel 1 street adjustment needs to be performed.</p><p> a. Use the cursor keys to align the hairlines to street to where first cut is to be performed in Channel 1. </p><p> b. Press and use the cursors to check the cutting positions</p><p> c. Press after aligning the hairline back to the first cut, end alignment with </p><p> the key and in the Hi mag mode </p><p>Use the F4 & F9 key to widen and narrow the airlines, this is useful in aligning to the street. Cut will be performed in the center of the hairlines</p><p>16. (Valid only in automatic cutting)After Channel 1 Street Adjustment, the stage is rotated 90 degrees and Channel 2 street adjustment needs to be performed, this is performed as in steps 14 a-c</p><p>17. Press the to begin dicing</p><p>Updated 01/05/2017 TJM 18. After the end of the dicing process, press , the wafer is brought back to the loading position and is declamped.</p><p>19. Open the hood and blow dry the sample before removing from the chuck.</p><p>20. To dice another sample with the same settings, load the sample and press and repeat steps 10-19</p><p>21. If you are done, press exit key repeatedly till the main menu screen appears on the monitor.</p><p>22. Press the to turn off the spindle and the cut water and to reinitialize the system. </p><p>23. Shutdown the system by using the system key.</p><p>24. Close the DI water, Spindle water and nitrogen valves on the back wall.</p><p>25. Disable DiscoDAD 641 in iLabs</p><p>Updated 01/05/2017 TJM</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    6 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us