AC1124 Residential Processing Checklist

AC1124 Residential Processing Checklist

<p>Residential processing checklist</p><p>Address: Consent No:</p><p>Processed by: Date:</p><p>Description of work:</p><p>Exposure zone Choose an item. Wind zone Choose an item.</p><p>Project Processors complexity Choose an item. competency Choose an item.</p><p>Risk group Application: ☐Building consent ☐Amends</p><p>LBP No: (Eng) LBP No: (Design)</p><p>The property address has been accessed in the computer system and the site file viewer ☐ ☐ checked to see if there are any issues that may affect the current application Yes No</p><p>PIM / PIC (list any non-standard issues raised in the PIM that affect this application to show they have been considered)</p><p>Means of Compliance</p><p>☐ NZS3604:2011 ☐ SED ☐ NASH ☐ NZS4229 ☐ Other </p><p>☐ BRANZ / BEAL appraisal No: ☐ Codemark Certificate No: </p><p>SED elements included in this application </p><p>☐ Foundations (pile) ☐ Floor (timber subfloor) ☐ Verandah beams ☐ Swimming pool</p><p>☐ Foundations (strip) ☐ Floor (timber mid-floor) ☐ Barriers ☐ Solar water heating</p><p>☐ Masonry walls ☐ Wall framing ☐ Bracing ☐ Wastewater ☐ Lift / Cable car</p><p>☐ Columns ☐ Beams ☐ Floor (slab) ☐ Stormwater ☐ Conservatory ☐ Lintels</p><p>☐ Retaining walls ☐ Roof framing / bracing ☐ Solid fuel heater ☐ Other (list below)</p><p>B2 Durability</p><p>Concrete strength (Mpa) Timber treatment Flashings and fixings</p><p>☐ 17.5 ☐ 20 ☐ 25 ☐ 30 ☐ H1.2 ☐ H3.2 ☐ H5 ☐ Type ☐ Compatibility ☐ Fixings ☐ Other</p><p>Page 1 of 17 May 2017 AC1124 (v.11) Additional checklists attached N/A ☐ ☐ SFH ☐ Solar ☐ Ancillary buildings ☐ Pool ☐ Re-clad ☐ On-site wastewater ☐ Other (list) </p><p>Page 2 of 17 May 2017 AC1124 (v.11) Decision General Reasons for decision / comments N/A ☐ Yes RFI N/A CoW provided for all RBW ☐ ☐ ☐ ☐ Designer ☐ Engineer Project complexity level confirmed and noted in ☐ ☐ ☐ computer Revised plans and amendments show changes ☐ ☐ ☐ (clouded); version number and date</p><p>Page 3 of 17 May 2017 AC1124 (v.11) Decision Geotechnical issues Reasons for decision / comments N/A ☐ Yes RFI N/A Full geotechnical appraisal report required if any of: 1. Hazards on AC GIS [Regulatory > Development Restrictions] and [Environment > Land Cover]. 2. Development on virgin land with slope >1:3 ☐ ☐ ☐ 3. Land classified as subject to hazard in PAUP Part 2 Chapter C Section 5.12 Policy 1. ☐ Professional Opinion (NZS4404:2010 Sch. 2A) Check engineering subdivision completion reports (Geotechnical Completion Report) as defined in Earthworks and Geotechnical CoP ☐ ☐ ☐ ☐ Professional Opinion (NZS4404:2010 Sch. 2A) Geotechnical reports have clearly defined scope and purpose, and meet requirements of Earthworks ☐ ☐ ☐ and Geotechnical CoP. Geotechnical Investigation Report identifies stage of investigation. Scope of investigation is appropriate ☐ ☐ ☐ (see Earthworks and Geotechnical CoP) Geotechnical Design Report records design inputs ☐ ☐ ☐ and construction monitoring requirements. If hazards exist attach AC1107a Natural Hazards ☐ ☐ ☐ processing checklist</p><p>Page 4 of 17 May 2017 AC1124 (v.11) Decision Site plan (items must be shown on plans) Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Siting dimensions 3 minimum shown on site plan ☐ ☐ ☐</p><p>Minimum (floor and finished ground) levels shown ☐ ☐ ☐ on site plan</p><p>Datum / contours ☐ ☐ ☐</p><p>☐ Garage ☐ Deck ☐ Pool All building works shown on site plan ☐ ☐ ☐ ☐ Outbuildings ☐ Ret walls</p><p>Main access to building shown on site plan ☐ ☐ ☐</p><p>Public & private drainage shown on site plan ☐ ☐ ☐ Location, connections, cess pits</p><p>Erosion and sediment control plan provided ☐ ☐ ☐</p><p>B1 Structure Decision Reasons for decision / comments N/A ☐ Landscape retaining walls Yes RFI N/A Construction details ☐ ☐ ☐ Footings, wall construction, height Drainage ☐ ☐ ☐ Clear of public drains, cess pit (size, cover)</p><p>Drainage medium, protection, tanking ☐ ☐ ☐</p><p>Surcharge ☐ ☐ ☐</p><p>Masonry type: A, B or C ☐ ☐ ☐</p><p>Barrier (safety from falling) ☐ ☐ ☐</p><p>Excavations within 1.0m of boundary or affecting ☐ ☐ ☐ neighbouring properties (Check GIS maps)</p><p>B1 Structure Decision Reasons for decision / comments N/A ☐ Strip footings Yes RFI N/A Footings ☐ ☐ ☐ Depth, size Horizontal reinforcing ☐ ☐ ☐ Size, c/s Vertical reinforcing / starters ☐ ☐ ☐ Size, c/s </p><p>Steps in foundations (due to ground slope) ☐ ☐ ☐</p><p>B1 Structure Decision Reasons for decision / comments N/A ☐ Piles, pads and posts Yes RFI N/A Pile foundation plan ☐ ☐ ☐ Depth, size, c/s, point loads Column and posts foundations / pads ☐ ☐ ☐ Depth, size Pile height ☐ ☐ ☐ 150 mm minimum 3.0m maximum Anchor / braced piles ☐ ☐ ☐ Footing size, pile height, connections Driven piles ☐ ☐ ☐ SED, NZS3604, consent condition</p><p>Page 5 of 17 May 2017 AC1124 (v.11) B1 Structure Decision Reasons for decision / comments N/A ☐ Masonry , concrete and retaining walls (fdn) Yes RFI N/A Wall height ☐ ☐ ☐ Minimum, maximum Vertical reinforcing (starters) ☐ ☐ ☐ Size c/s Horizontal reinforcing (bond beam) ☐ ☐ ☐ Size, c/s, block size Masonry type – A, B or C ☐ ☐ ☐ Surcharge Split level ☐ ☐ ☐ Drainage, tanking, strapped, lined</p><p>B1 Structure Decision Reasons for decision / comments N/A ☐ Slab Yes RFI N/A Type: SED (PS1) (PS2) NZS3604 ☐ ☐ ☐ Slab-on-grade, raft, suspended floor </p><p>Edge beam, ribs, starters ☐ ☐ ☐</p><p>Base preparation / hard-fill ☐ ☐ ☐ 75mm min, 600mm max, sand </p><p>Slab (thickness) ☐ ☐ ☐</p><p>Membrane (type) ☐ ☐ ☐ Plumbing pipes not running through point load pas ☐ ☐ ☐ or slab thickenings (X-check truss plan) Shrinkage control, free joints ☐ ☐ ☐ Internal corners; max. length of slab</p><p>Mesh (type) 500E ☐ ☐ ☐</p><p>Point loads pads / slab thickenings ☐ ☐ ☐</p><p>Additions ☐ ☐ ☐ Connection to existing slab</p><p>B1 Structure Decision Reasons for decision / comments N/A ☐ Subfloor framing and bracing Yes RFI N/A Subfloor bracing calculations ☐ ☐ ☐ Zone, demand, capacity Subfloor bracing plan indicating type, location, ☐ ☐ ☐ length 5.0m c/s, 4 min, evenly distributed</p><p>2-storey (height vs. width) ☐ ☐ ☐</p><p>Diaphragms ☐ ☐ ☐ > 100 BUs, location, limitations Bearers Size, c/s, span, point loads, C/L, loading, fixing to ☐ ☐ ☐ foundation walls Joists Size, c/s, span, point loads, C/L, loading, ☐ ☐ ☐ penetrations Cantilever joist ☐ ☐ ☐ 2.4m max. height, support for L/B walls Lateral support ☐ ☐ ☐ Mid-span, blocking, bracing lines Flooring ☐ ☐ ☐ Thickness, clearances, type Base cladding Type, support, access, ventilation, crawlspace, ☐ ☐ ☐ vermin proofing, obstructions, large area, ltd x-flow</p><p>Page 6 of 17 May 2017 AC1124 (v.11) B1 Structure Decision Reasons for decision / comments N/A ☐ Subfloor framing and bracing Yes RFI N/A</p><p>Provision for surface water runoff sloping sites ☐ ☐ ☐</p><p>B1 Structure Decision Reasons for decision / comments N/A ☐ Mid-floor Yes RFI N/A Structure/load path Beams/posts, SED, timber, steel, flitch, engineered ☐ ☐ ☐ timber, suspended concrete Joists C/L, floor load, penetrations, size, C/s, span, point ☐ ☐ ☐ loads Flooring ☐ ☐ ☐ Type, diaphragm </p><p>B1 Structure deck construction (ground floor or Decision Reasons for decision / comments N/A ☐ external decks above ground floor) Yes RFI N/A Piles ☐ ☐ ☐ Size, depth, c/s, height Bearer ☐ ☐ ☐ 2.0 kPa, size, span, c/s, cantilever Joists ☐ ☐ ☐ 2.0 kPa, size, span, C/s, cantilever, saddle flashings Decking material ☐ ☐ ☐ Slip resistance, type, fixings, FFL Stringer ☐ ☐ ☐ Size, span, fixings, air-gap</p><p>Subfloor deck bracing if >2.0m in width ☐ ☐ ☐</p><p>Slab / patio ☐ ☐ ☐ Connection to slab, FFL Stairs and landings Type, tread, riser, pitch, openings, sip resistance, ☐ ☐ ☐ handrail </p><p>Decision B1 Structure barrier design Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>AS1170; NZS4223; (other) ☐ ☐ ☐</p><p>Barrier construction ☐ ☐ ☐ SED, materials, fixings, openings, height Loadings ☐ ☐ ☐ Indoors / outdoors / common areas Glazing (PS1 covers all aspects of design and ☐ ☐ ☐ fixings)</p><p>Consequences of failure (B1.3.4) ☐ ☐ ☐</p><p>B1 Structure Decision Reasons for decision / comments N/A ☐ Framing – lower of two Yes RFI N/A Bottom plate ☐ ☐ ☐ Size, fixings Top plate ☐ ☐ ☐ Size, point loads Studs and trimmers ☐ ☐ ☐ Size, height, C/s, point loads </p><p>Gable end framed for cladding ☐ ☐ ☐</p><p>Page 7 of 17 May 2017 AC1124 (v.11) B1 Structure Decision Reasons for decision / comments N/A ☐ Framing – lower of two Yes RFI N/A</p><p>Uplift fixings detailed for studs ☐ ☐ ☐</p><p>Lintels / beams ☐ ☐ ☐ Point loads, fixing details, size, span, uplift, C/L </p><p>B1 Structure Decision Reasons for decision / comments N/A ☐ Framing – ground or upper floor Yes RFI N/A Bottom plate ☐ ☐ ☐ Size, fixings Top plate ☐ ☐ ☐ Size, point loads Studs and trimmers ☐ ☐ ☐ Size, height, C/s, point loads </p><p>Gable end framed for cladding ☐ ☐ ☐</p><p>Uplift fixings detailed for studs ☐ ☐ ☐</p><p>Lintels / beams ☐ ☐ ☐ Point loads, fixing details, size, span, uplift, C/L </p><p>B1 Structure Decision Reasons for decision / comments N/A ☐ Wall bracing (all floors) Yes RFI N/A Wall bracing calculations ☐ ☐ ☐ Zone, demand, capacity Wall bracing plan indicating ☐ ☐ ☐ Type, location, length Bracing capacity external walls ☐ ☐ ☐ >100 BU, 50% demand, 15 BUs / m Bracing capacity internal walls ☐ ☐ ☐ > 100 Bus, 50% total demand Location of bracing elements 6.0m c/s, evenly distributed, wings, blocks, wet ☐ ☐ ☐ areas, split or discontinuous levels Dragon ties to extend brace lines to 7.5m ☐ ☐ ☐ > 100 Bus, location Ceiling diaphragm ☐ ☐ ☐ > 100 Bus, location, limitations</p><p>B1 Structure Decision Reasons for decision / comments N/A ☐ Roof and ceiling framing Yes RFI N/A Roof type (pitch) ☐ ☐ ☐ Pitched, trussed Trusses ☐ ☐ ☐ Design statement, software statement, truss layout</p><p>Roof bracing ☐ ☐ ☐</p><p>Rafter / ridge beam ☐ ☐ ☐ Size, span, support, fixings Skillion roof ☐ ☐ ☐ Type, thickness, fixing </p><p>Purlin, tile batten, size, span, C/s, fixings ☐ ☐ ☐</p><p>Membrane roof framing (joists) ☐ ☐ ☐ Size, span, C/s, fixings, fall Ceiling battens ☐ ☐ ☐ Size, span, C/s, fixings, ceiling lining</p><p>Page 8 of 17 May 2017 AC1124 (v.11) Decision C1 Fire protection Reasons for decision / comments N/A ☐ Yes RFI N/A Means of compliance with Clauses C1 – C6 ☐ ☐ ☐ ☐ C/AS1-C/AS7 Relevant or notional boundary distance (distance measured from cladding not foundation) ☐ External wall <1.0 to boundary ☐ ☐ ☐ ☐ Eaves <650mm to boundary ☐ 2.0m between any two buildings on site</p><p>Escape height ☐ Under 10m ☐ ☐ ☐</p><p>Escape paths ☐ Open ☐ Dead end ☐ ☐ ☐</p><p>FRR construction ☐ ☐ ☐ ☐ Details on plans ☐ No foamed plastics Non-combustible surfaces ☐ ☐ ☐ ☐ Appliances ☐ Chimney Inter-tenancy walls ☐ ☐ ☐ ☐ Junctions ☐ Neighbours approval</p><p>Scope of risk group (Table 1.1) (Para. 1.1.1) ☐ ☐ ☐</p><p>Part 2: Fire safety system (Para. 2.2) ☐ ☐ ☐</p><p>Part 3: Means of escape (DEOP, TOP) (Table 3.2) ☐ ☐ ☐</p><p>Part 4: Fire separations (Para. 4.1) ☐ ☐ ☐</p><p>Structural stability to resist 0.5kPa fire load ☐ ☐ ☐</p><p>Roof projection (Para. 5.2) ☐ ☐ ☐</p><p>Exterior surface finish (Para. 5.4) (Table 5.1) ☐ ☐ ☐</p><p>Fire properties of external wall cladding system determined in accordance with ☐ C/AS1 App. C7.1 and limits of Table 5 ☐ ☐ ☐ ☐ AS1530.1 non-combustible materials  refer C/AS1 App. C and C7.1.4 Testing in accordance with C/AS1 App. C and C7.1.2: ☐ Heat flux 50kW/m2 ☐ Test duration 15 minutes ☐ ☐ ☐ ☐ Total heat release measured from start of test ☐ Total heat release measured from sample orientation horizontal ☐ Ignition initiated by external spark igniter Timber external wall cladding system tested in accordance with C/AS1 App. C, C7.1 and must be subjected to accelerated weathering described by ☐ ☐ ☐ ASTM D 2898 Method B with water flow rate from Method A before testing to C7.1 Claddings incorporating a metal facing with a melting point of <7500 covering a combustible core ☐ ☐ ☐ or insulant tested in accordance with App. C7.1 without the metal facing present </p><p>Solid fuel appliances (C/VM1) (AS/NZS 2918) ☐ ☐ ☐</p><p>Gas burner (NZS5261) - Para. 7.2 ☐ ☐ ☐</p><p>Page 9 of 17 May 2017 AC1124 (v.11) Decision C1 Fire protection Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Oil fire (AS1691) - Para. 7.3 ☐ ☐ ☐</p><p>Open fire - Para. 7.5 ☐ ☐ ☐</p><p>Down lights (Para. 7.4) ☐ ☐ ☐</p><p>Referred to fire engineer ☐ ☐ ☐</p><p>Decision D1 Access (internal and external) Reasons for decision / comments N/A ☐ Yes RFI N/A Stairs / slip resistance ☐ ☐ ☐ Internal, external, type, tread, pitch, riser Landings top and bottom of all stairs and ramps ☐ ☐ ☐ Handrails provided to stairs > 3 risers Stairwell ☐ ☐ ☐ Width, height </p><p>Decision D2 Lifts or cable cars Reasons for decision / comments N/A ☐ Yes RFI N/A Design calculations and specifications ☐ ☐ ☐ D2/AS1, EN/81, PS2</p><p>Decision E1 Surface water Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Sediment and erosion control plans provided ☐ ☐ ☐</p><p>Overflow path / runoff to other land ☐ ☐ ☐ Flood report Downpipes and external gutters ☐ ☐ ☐ No, size, distribution, spreaders Stormwater run-off (paved areas >10 m²) ☐ ☐ ☐ Cesspit size, cut-off drain garage / basement Stormwater drainage Public, Soak hole, detention tank, rainwater tank/ ☐ ☐ ☐ dual purpose tank Stormwater drainage detention tank, rainwater tank, dual purpose tank ☐ ☐ ☐ inlet leaf strainer/ first flush/ drain Public drains affected / approval ☐ ☐ ☐ Approval, easements </p><p>Decision E2 External moisture Reasons for decision / comments N/A ☐ Yes RFI N/A Building subject to re-clad; E2 risk >12 ☐ ☐ ☐ ☐ Send to re-clad team for review</p><p>E2 risk matrix (confirm and note score) ☐ ☐ ☐ Wall cladding (type) E2/AS1, alt. solution, maintenance and installation ☐ ☐ ☐ details Wall cladding clearances ☐ ☐ ☐ Ground, deck, wall, roof Building wrap ☐ ☐ ☐ Type, compatibility, strapping Air barrier ☐ ☐ ☐ Rigid, non-rigid Cavity battens ☐ ☐ ☐ Size, type, fixing, vermin proof Page 10 of 17 May 2017 AC1124 (v.11) Decision E2 External moisture Reasons for decision / comments N/A ☐ Yes RFI N/A Window details ☐ ☐ ☐ E2/AS1, alt. solution Wall junction details ☐ ☐ ☐ E2/AS1, SED, alt. solution Barge, fascia, spouting to wall junction details ☐ ☐ ☐ E2/AS1, SED, alt. solution Internal gutters and roof penetrations Slope, size, scupper, overflow, flashing details for ☐ ☐ ☐ roof penetrations</p><p>Control joints / junctions ☐ ☐ ☐</p><p>Flashing details E2/AS1, alt. solution, roof, wall, pergola, chimney, ☐ ☐ ☐ apron, pipes, joinery, meter box Parapets / enclosed barriers ☐ ☐ ☐ Framing, cap, drainage, junctions, slope </p><p>Internal decks Joists, slope, junctions, drainage, FFL, air-gap, ☐ ☐ ☐ fixings, saddle, 2nd floor limitations NB - no direct fixed tiles permitted</p><p>Roof cladding / underlay (type) E2/AS1, alt. solution, maintenance and installation ☐ ☐ ☐ details Membrane substrate (type) E2/AS1, alt. solution, thickness, fixing, venting, ☐ ☐ ☐ control joints Split level ☐ ☐ ☐ Drainage, tanking, strapped, lined</p><p>Decision E3 Internal moisture Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Waterproofing (type) ☐ ☐ ☐</p><p>Ventilation / condensation control ☐ ☐ ☐</p><p>Showers, urinals, baths – impervious surfaces walls ☐ ☐ ☐ and floors Wall junction to fixtures ☐ ☐ ☐ Bath, basin, sink , tub, urinal, kitchens Thermal resistance walls / ceiling; thermal break for ☐ ☐ ☐ steel framing</p><p>Overflow provision (other property) ☐ ☐ ☐</p><p>Decision F1 Hazardous agents on site Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Contamination checked on PIR (HSNO) ☐ ☐ ☐</p><p>Decision F2 Hazardous building materials Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>F2/AS1, NZS4223.3 ☐ ☐ ☐</p><p>Asbestos products especially in adds / alts pre 1990 ☐ ☐ ☐ ☐ Advice note required Glazing, human impact (thickness, safety glass) ☐ ☐ ☐ Shower, skylights, windows, stair, foyers</p><p>Page 11 of 17 May 2017 AC1124 (v.11) Decision F2 Hazardous building materials Reasons for decision / comments N/A ☐ Yes RFI N/A Barrier NZS4223.3:2016 ☐ ☐ ☐ Glass type, height, system, fixings</p><p>Decision F4 Safety from falling Reasons for decision / comments N/A ☐ Yes RFI N/A Fixed window seat ☐ ☐ ☐ ☐ lower edge of opening measured from seat WC or any other fixed feature within 500mm horizontal of a window ☐ ☐ ☐ ☐ lower edge of opening measured vertically from the pan or feature Windows with opening width <1.0m and lower edge of opening within 760mm of floor ☐ ☐ ☐ ☐ Restrictor (100mm); or ☐ 760mm high barrier Windows with opening width >1.0m and lower edge of opening within 1.0m of floor ☐ ☐ ☐ ☐ Requires barrier (refer Table 1) Barrier construction details (stairs) ☐ ☐ ☐ Height, SED, balusters, palings, openings Any additions / alterations affecting existing pool ☐ ☐ ☐ barrier – refer to F9</p><p>Decision F7 Warning systems Reasons for decision / comments N/A ☐ Yes RFI N/A Smoke alarms shown on plan ☐ ☐ ☐ Type, location </p><p>Decision G1 Personal hygiene Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Suitable facilities ☐ ☐ ☐</p><p>Basins provided within or adjacent to WC ☐ ☐ ☐</p><p>Minimum room size (WC) ☐ ☐ ☐</p><p>Decision G2 Laundering Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Laundering facilities provided to Table 1 ☐ ☐ ☐</p><p>Working space ☐ ☐ ☐</p><p>Impervious surfaces ☐ ☐ ☐</p><p>G3 Food preparation and prevention of Decision Reasons for decision / comments N/A ☐ contamination Yes RFI N/A Cooker, oven, fridge, food storage space provided ☐ ☐ ☐ Work space Prep bench and sink provided ☐ ☐ ☐ Size, capacity, surface finishes</p><p>Decision G4 Ventilation Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Natural ventilation 5% of floor area ☐ ☐ ☐</p><p>Laundry / WC – natural or mechanical ☐ ☐ ☐</p><p>Page 12 of 17 May 2017 AC1124 (v.11) Decision G4 Ventilation Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Ensuite / Bathroom – natural or mechanical ☐ ☐ ☐</p><p>Fumes and odours collection / disposal ☐ ☐ ☐</p><p>Ventilation for gas appliances ☐ ☐ ☐ Hob, bayonet, HWC to AS/NZS 5601.1.</p><p>Decision G6 Airborne and impact sound Reasons for decision / comments N/A ☐ Yes RFI N/A STC 55 between household units ☐ ☐ ☐ Type, system, construction details</p><p>Decision G7 Natural light Reasons for decision / comments N/A ☐ Yes RFI N/A Windows ☐ ☐ ☐ 10% of floor area, 50% clear to habitable area Restricted light ☐ ☐ ☐ Daylight angle, reflectance finishes</p><p>Awareness of outdoor environment ☐ ☐ ☐</p><p>Page 13 of 17 May 2017 AC1124 (v.11) Decision G9 Electricity Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Energy works certificate ☐ ☐ ☐</p><p>Electrical structures (pylons, transformers, poles ☐ ☐ ☐ and stays) check GIS</p><p>G10 – G11 Piped services & gas as an energy Decision Reasons for decision / comments N/A ☐ source Yes RFI N/A</p><p>Specifications ☐ ☐ ☐</p><p>Ventilation of appliances ☐ ☐ ☐ Heating, cooking, hot water – refer AS/NZS 5601.1 Location and size of gas cylinders ☐ ☐ ☐ Windows, drains, size</p><p>Decision G12 Water supplies Reasons for decision / comments N/A ☐ Yes RFI N/A Water supply (potable) cold water ☐ ☐ ☐ ☐ AS/NZS 3500.1 ☐ G12 AS1 Water supply (potable) ☐ ☐ ☐ Town, rainwater, bore, other Water supply (potable) hot water ☐ ☐ ☐ ☐ AS/NZS 3500.4 ☐ G12 AS1 HWC type ☐ ☐ ☐ Mains, low, solar (attach checklist), gas HWC location ☐ ☐ ☐ Internal, external HWC / header tank in roof space ☐ ☐ ☐ Access, support, overflow ☐ Retention tank ☐ Rainwater tank ☐ ☐ ☐ ☐ Dual purpose tank Inlet leaf strainer / first flush / drain / backflow Operating devices and valves ☐ ☐ ☐ Backflow, other Non-potable supply ☐ ☐ ☐ Separate system, schematic plan, outside tap, WC</p><p>Lilac pipes, warning signs, non-return valve ☐ ☐ ☐</p><p>Wetback pipework, tempering valve; low pressure - ☐ ☐ ☐ open vented</p><p>Decision G13 Sanitary plumbing and drainage Reasons for decision / comments N/A ☐ Yes RFI N/A Plumbing ☐ AS/NZS 3500.2.2015 ☐ G13/AS1 ☐ ☐ ☐ ☐ Other (specify) If AS/ NZS 3500.2 specify system ☐ Fully vented ☐ Fully vented modified ☐ Single stack ☐ ☐ ☐ ☐ Single stack modified ☐ Drainage principles ☐ Plumbing schematic supplied</p><p>Stacks, vents, systems, size, fall, material ☐ ☐ ☐</p><p>Discharge pipes ☐ ☐ ☐ Material, falls, size </p><p>Page 14 of 17 May 2017 AC1124 (v.11) Decision G13 Sanitary plumbing and drainage Reasons for decision / comments N/A ☐ Yes RFI N/A Drainage ☐ AS/NZS 3500.2.2015 ☐ G13/AS2 ☐ ☐ ☐ Drainage schematic supplied Overflow relief gully / gully trap ☐ ☐ ☐ Gully trap, ORG Combined waste / storm water systems ☐ ☐ ☐ Separated Drainage connections ☐ ☐ ☐ Invert level, reflux valve Angle of influence ☐ ☐ ☐ Depth and proximity of drain to building Sewer under or within 2.0m of building ☐ ☐ ☐ Drainage engineering approval Drains entering other properties ☐ ☐ ☐ Neighbour’s approval / easements Onsite effluent system (type) ☐ ☐ ☐ Attach checklist</p><p>Decision G15 Solid waste Reasons for decision / comments N/A ☐ Yes RFI N/A Space and access at ground level for refuse; ☐ ☐ ☐ screening in place</p><p>80l capacity per dwelling / max carry distance 30m ☐ ☐ ☐</p><p>Floors graded 1:50; waste and tap ☐ ☐ ☐</p><p>Chutes – access; size; surfaces; sprinkler ☐ ☐ ☐ (compliance schedule); ventilation</p><p>Decision H1 Energy efficiency Reasons for decision / comments N/A ☐ Yes RFI N/A Means of compliance ☐ ☐ ☐ H1/AS1, NZS4218, NZS4214 Method ☐ ☐ ☐ Schedule, calculation, modelling Insulation type and R values detailed on plans ☐ ☐ ☐ Sub floor, walls, ceiling Insulation ☐ ☐ ☐ 25mm clearance from underside of roofing Glazing requirements ☐ ☐ ☐ Single, double </p><p>Thermal break to metal framing ☐ ☐ ☐</p><p>Hot water system insulated ☐ ☐ ☐ H1/AS1 NZS4305 s.5 Garages included / excluded ☐ ☐ ☐ Included min. R-value 1.5 (E3/AS1)</p><p>Decision Producer statements / certificates required Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>Risk level (AC2303) Low, Medium ☐ ☐ ☐</p><p>PS author working within scope of approval and ☐ ☐ ☐ insurance has not lapsed ☐ Geotechnical ☐ Structural ☐ ☐ ☐ ☐ Fire ☐ Acoustic ☐ Glazing Other (list) ☐ ☐ ☐</p><p>Page 15 of 17 May 2017 AC1124 (v.11) Decision Producer statements / certificates required Reasons for decision / comments N/A ☐ Yes RFI N/A Construction monitoring – info provided about ☐ ☐ ☐ inspections to be performed by engineer</p><p>Decision Requests for further information N/A ☐ Date requested Date resolved Signed Yes N/A</p><p>Information requested ☐ ☐</p><p>Information requested ☐ ☐</p><p>Decision Building Act matters Reasons for decision / comments N/A ☐ Yes RFI N/A</p><p>S.14G M/F or suppliers product technical statement ☐ ☐ ☐</p><p>S.67 Waivers and modifications ☐ ☐ ☐</p><p>S.84 Restricted building work ☐ ☐ ☐</p><p>S.72 Hazards (stability / flooding) ☐ ☐ ☐ Condition, registration on title, attach checklist S.75 Building on 2 or more allotments ☐ ☐ ☐ Condition, registration on title S.112 Alterations to ex. Buildings complies to same ☐ ☐ ☐ extent as before alts, escape paths</p><p>Decision Decision Final check / sign off Final check / sign off Yes N/A Yes N/A</p><p>Agreement to provide PS 3 & 4 ☐ ☐ Development contribution (Form 3) ☐ ☐</p><p>Document sets collated and stamped ☐ ☐ S.72 lodged with LINZ ☐ ☐</p><p>Superseded plans separated / retained ☐ ☐ S.75 lodged with LINZ ☐ ☐</p><p>Other checklists attached ☐ ☐ Modification / Waiver (to Mgr. Durability) ☐ ☐</p><p>Plans signed by engineer ☐ ☐ Inspection requirements identified ☐ ☐</p><p>LBP; NZRAB (NZIA); CPEng registers Structural / geotechnical engineering ☐ ☐ ☐ ☐ checked</p><p>Public drainage / approvals ☐ ☐ Conditions completed ☐ ☐</p><p>PIM issues resolved ☐ ☐ Computer tasks completed ☐ ☐</p><p>RMA issues (Form 4) ☐ ☐ File handed onto admin / invoicing ☐ ☐</p><p>Final sign off (signature) Yes No</p><p>I am satisfied on reasonable grounds that compliance has been established with the Building Code and the building ☐ ☐ consent / amendment is approved and ready for granting</p><p>Name: Date: </p><p>Supervision (signature) ☐ N/A</p><p>Supervisor: Date: </p><p>If supervised, supervision form must be completed and forwarded to [email protected]</p><p>Page 16 of 17 May 2017 AC1124 (v.11) Comments:</p><p>Page 17 of 17 May 2017 AC1124 (v.11)</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    17 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us