Wet Exhaust Temperature Alarm

Wet Exhaust Temperature Alarm

<p> SINGLE ENGINE RAW WATER FAILURE ALARM.</p><p>ALARM PANEL MOUNTING AND CONNECTION. Drill 1-7/8 TO 2” hole for mounting alarm unit. Do not attempt to remove knurled nut on face plate. Run all wires through protective boot before making any wire connections. Note: alarm panel draws no current except when in alarm mode. Connect OPTIONAL REMOTE HORN CONNECTIONS. Remote is useful for flybridge installations. See wire diagram . </p><p>SENSOR INSTALLATION. Sensor band will fit exhaust hose in the range of 2” to 7” diameter. For larger diameter exhaust hose, use extension kit for up to 14” diameter. Locate band down stream of water injection just after existing stainless steel hose clamps. Sensor should be mounted as shown in FIGURE TWO. At sensor, form band around hose with fingers. Band should be square with hose and not at any angle. Tension band until snug and lock in place. See FIGURE THREE. Secure wires to exhaust hose using provided nylon wire tie. Alarm modules for V-8/6 engines will have two band sensors. Mount each band on each cylinder bank as described above. Insure wires will not snag moving parts such as propeller shaft or belts. Keep cable way from hot exhaust areas before water injection point. Insure cable(s) will not chafe against sharp edges.</p><p>ALARM WIRING AND TEST</p><p>Wire alarm as shown in schematic below. Wire horn to switched side of ignition switch.. In the event of an alarm condition, turning off ignition switch will silence alarm. Connect sensor BLACK wire to local ground (Neg ----) at engine. Connect PURPLE wire to horn. To test alarm, remove and save protective caps on BROWN test port wires. Turn on ignition switch and short brown wires together. Alarm should sound and LED on front face should light. After test, replace protective caps on BROWN wires. </p><p>SPECIFICATIONS: Operating voltage: 10.5 to 15V DC Alarm Setpoint (fixed) 75°C (167°F) Current draw (alarm module only) : 20mA Max Current load on control wire: 0.5A Switching function alarm condition: Signal wire goes low at temperature exceeding setpoint. Sensor Band: Nylon coated stainless steel with fast acting thermal switch. . Max operating temperature 150°C (300°F) </p><p>BOREL MANUFACTURING INC.  510 864 0237  WEBSITE: www. borelmfg.com E-MAIL: borelmfg @ earthlink.net SS HOSE CLAMPS WATER INJECTION POINT SENSOR WATER INJECTION BAND POINT BAND CLAMP SENSOR CABLE 90 deg ENGINE</p><p>SE THIS O BLOCK H T AREA S SENSOR U A VERY H EX HOT!</p><p>TO OVERBOARD DISCHARGE OR WATER LIFT MUFFLER FIGURE ONE FIGURE TWO SENSOR INSTALLATION END VIEW OF EXHAUST HOSE</p><p>BAND SENSOR</p><p>SENSOR TEST BROWN SECOND BAND PORT SENOR ON WIRES V-8/6 MODULES ONLY.</p><p>BLACK (---) NEG (ATTACH AT ENGINE)</p><p>PURPLE</p><p>TO ENGINE</p><p>+12 VDC (+) (+) (--) +12VDC (--) IGNITION SW</p><p>OPTIONAL REMOTE ALARM MAIN ALARM PANEL PANEL</p><p>TYPICAL INSTALLATION LOCKING BAND CLAMP INSTALLATION See “FIG TWO, End view exhaust hose” for FIGURE THREE Sensor location</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us