<p> HUSHCORE UnitaryPlus™ ”TM” System For Air-Cooled Chillers</p><p>PART 1 – GENERAL 1.1 WORK INCLUDED A. The work consists of furnishing a HUSHCORE™ UNITARYPLUS™ “TM” Chiller Noise Reduction System as described in this specification.</p><p>1.2 SUBMITTALS A. Product Data: 1. Manufacturer’s original catalog cut sheets and material description for each sub-component incorporated into the system. 2. “Or Equal” approval of the Acoustical Package will be given upon submission and review 10 days prior to bid day.</p><p>1.3 QUALITY ASSURANCE A. Single Source Requirements: 1. Provide a HUSHCORE™ UNITARYPLUS™ “TM” Chiller Noise Reduction System from a single manufacturer. 2. The chiller equipment manufacturer shall furnish the HUSHCORE™ System. 3. The HUSHCORE™ Noise Reduction System shall be installed by the specified product manufacturer.</p><p>B. Manufacturer Qualifications: 1. Company specializing in the manufacture of acoustical systems and related accessories with not less than 35 years documented successful experience with work comparable to work of this project. 2. Design Requirements: a) Design system to meet chiller manufacturers published data pertaining to heat loss of compressors, condenser fan airflow, and ensure no “de-rating” of chiller performance. b) Design system to meet all environmental conditions such as temperature, wind, shrinkage, UV-rays, and moisture.</p><p>PART 2 – PRODUCT 2.1 MANUFACTURER</p><p>A. BRD Noise and Vibration Control, Inc., PO Box 127, 112 Fairview Avenue, Wind Gap, PA, 18091, Phone: (610) 863-6300, Fax: (610) 863-4230, E-mail: [email protected], Website: www.HUSHCORE.net. </p><p>2.2 MATERIALS</p><p>A. HUSHCORE™ UNITARYPLUS™ “TM” Chiller Noise Reduction System: 1) HUSH GUARD™ Modular Metal Panels, Part Number HGU-400, Metal Acoustical Panels shall be pre-fabricated, sectional, all metal-clad, modular and designed for easy and accurate assembly and disassembly. The acoustical panels and components are designed to surround the condenser fans on air cooled chillers. The panels are mounted directly onto the chiller top (equipment manufacturer approval required), with sheet metal floor channels for positioning 3 x 3 structural vertical angle braces along both sides of the chiller. The acoustical discharge plenum height shall be as required to meet acoustical performance in 2.3. Top Mounted UNITARYPLUS™ Systems cannot be wind load rated. 2) HUSH GUARD HGU-400 Metal Acoustical Panels shall be constructed with galvanized steel sheet metal and core insulation suitable for exposure to the elements. The panels shall be rated at STC-42 minimum. All structural angles shall be painted or galvanized. The panels and components shall not be susceptible to damage due to extended exposure to vibration, air temperature, UV rays or humidity with passage of time. </p><p>HUSHCORE™ UnitaryPlus™ “TM” System For Air-Cooled Chillers – (2-22-16) Page 1 of 2 3) Double skin perf/perf HUSH GUARD™ HG-400-PP splitter baffles shall be installed in the top of the acoustical exhaust plenum. Spacing, depth and baffle thickness shall be as required to meet acoustical and aerodynamics of the selected chiller manufacturer’s model.</p><p>2.3 ACOUSTICAL PERFORMANCE</p><p>A. The UnitaryPlus™ “TM” System HUSH GUARD™ panels shall meet or exceed the Transmission Loss values at every octave band when tested in accordance with ASTM E-90-10 as listed below.</p><p>Freq. (Hz) 125 250 500 1000 2000 4000 STC TL (dB) 23 31 40 49 56 62 42</p><p>B. When operating at worst case noise conditions, the chiller with prescribed noise treatments shall not exceed [ ] at a distance of [ ], assuming no contribution from ambient background sources.</p><p>C. Chiller sound power levels with the HUSHCORE™ UnitaryPlus™ “TM” System shall not exceed the following levels in any octave band.</p><p>63 125 250 500 1000 2000 4000 8000 dBA [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ]</p><p>D. Acoustical reading shall be supplied by the chiller manufacturer after completed installation. Readings shall be conducted by a qualified acoustical consultant.</p><p>HUSHCORE™ UnitaryPlus™ “TM” System For Air-Cooled Chillers – (2-22-16) Page 2 of 2</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us