To Je URSP Predloga

To Je URSP Predloga

<p> DETENTIONS IN PORT OF KOPER IN THE YEAR 2007</p><p>1 2 3 4 5 6 Date & Vessel Name, Flag Owners Classification Summary Place of Type, IMO No & Operator Society Detention GT Charterers 06/01/2007 IBRAHIM M Bolivia Phoenicia Guardian Detained for 6 days. Maritime Bureau of 16 recorded deficiencies. Koper General cargo Shipping IOPP certificate not Tartous properly filled. Air 7026550 condition cables Syria improperly installed 1973 through cabins bulkheads. Stern anchor lights with improper corrugated glass. In hold aft PS wing tank bulkhead corroded through in two places. Standard discharge connection not in accordance with MARPOL, In FP frames corroded through. In FP platforms corroded through. Bulkhead between FP and trim tank corroded through. In FP beams corroded through. Gusset plates around the trunk place corroded through. In hold FWD STB three frames corroded through. In hold FWD STB air pipe corroded through. In hold FWD PS all frames corroded through. Steering gear room air vent corroded through. OFE inoperative. ISM maintenance of ship and equipment failed. 06/01/2007 EMIRBEY Turkey Tango Turkish Lloyd Detained for 5 days. Gemiclik 14 recorded deficiencies. Koper General cargo Magnetic compass fell Istanbul from gimble. On master 7364546 cabin scuttle window Turkey glass cracked. On hold 2 745 aft hatch covers frames corroded through. Last cleat holder cracked around. PS outside top of hatchcoaming cracked. On hold 2 hatch covers cracked and frames corroded through. On hold 1 hatch covers and frames corroded through. Stem detached from bow. One before last frame detached. In FCSL two frames bent. Last gusset plate heavy buckled. PS chain pipe on top windlass cracked. ISM maintenance of ship and equipment failed. In hold 2 aft the ship has water ingress through the hatch covers. 08/01/2007 IVAN MAKARIN Russia Far eastern Russian Detained for 3 days. shipping c. Maritime 21 recorded deficiencies. Koper Bulk carrier Register of Fuel pipe which pass Vladivostok Shipping through tank no 20 8131908 leaking. Lift ventilation Russia shaft corroded through. 14.043 All buckets under air pipes full of oily water. Battery room bulkhead corroded through. Radio room bulkhead corroded through. Battery room door corroded through. Alleyway bulkhead corroded through. Bridge bulkhead corroded through. Store bulkhead corroded through. Radio room air vent corroded through. Funnel dampers sized. ER air vent door corroded through. Ch. eng cabin bulkhead corroded through. Electrical cables defence not as required. DG no 2 fuel leaking. Cooling water pump leaking. ER bilge to be dried and cleaned. Illegal flange fitted on OFE outboard pipe. Illegal pipe connected to outboard in steering room.. Air cooler pipe leaking. Sludge tank no 28 full, to be emptied before departure. 15/01/2007 AP LIGHT Cambodia Partner Ltd. Posski Rejstr Detained for 350 days. Statkov 24 recorded deficiencies. Koper General cargo Rostov on Safe manning certificate Don expired. IOPP certificate 7628863 expired. Chart 1471 Russia missing. Wheelhouse 3419 bulkhead corroded through. Main magnetic compass with big air bubble. Alleyway threshold corroded through. Battery room bulkhead corroded through. Three lifebuoys in bad condition. Second eng. cabin bulkhead corroded through. Galley air vent corroded through. On davits limit switches sized. Top of tank no 2 STB cracked. Wing tank no 2 bulkhead corroded through. Windlass oil leaking. Hatch covers hydraulic pipes leaking. Emergency fire pump engine oil leaking. DG no 1 fuel leaking alarm inoperative. Both cold room compressors inoperative. No sufficient food quantity on board. Crew does not use personal protective equipment. ME cooling water leaking. Due to improper lub oil ME with insufficient power. ISM maintenance of ship and equipment failed. 19/01/2007 YASAR Georgia Boss 97 International Detained for 3 days. CAPTAN 3 Register of 27 recorded deficiencies. Koper Constanta Shipping On STB side one scuttle General cargo frame corroded through. Romania In wheelhouse both 7643435 wipers inoperative. Skylight corrosion 3504 temporary repaired with tape, six skylight glasses cracked. Wheelhouse bulkhead corroded through. Pilot cabin bulkhead corroded through. Cadet cabin bulkhead corroded through. On outside food store door glass missing. Alleyway bulkhead corroded through. Electric switches room bulkhead corroded through. PS saloon bulkhead corroded through. In collision 17 metres of deck damaged with rupture. Boatswain cabin bulkhead corroded through. DB 3 tank air pipe corroded through. DB2 tank air pipe corroded through. On saloon window glass cracked. EFP insufficient pressure. One fire hose holed. On main boiler safety valve disconnected. In ER three possible illegal discharge valves fitted on PS hull. Electrical revolution regulator disconnected. On ME jacketed piping missing and disconnected. Fuel leaking alarm on ME inoperative. ER fire sensors inoperative. ER bilge to be dried and cleaned. In poop store two possible illegal discharge valves fitted on hull. ISM emergency preparedness failed. ISM maintenance of ship and equipment failed. 22/01/2007 RAVANDA Turkey Gemar American Detained for 96 days. Denizcilik Bureau of 15 recorded deficiencies. Koper General cargo Shipping Chart 1471 not up to Istanbul date. ER air vent 7819450 corroded through. Turkey Manual wire for horn 1814 activation torn. Ship's horn inoperative. Signal mast corroded through. On PS lifeboat gunwale holed. On STB lifeboat gunwale holed. Front bridge bulkhead corroded through. Officer saloon bulkhead not watertight. Bottom of PS save all not as required, DO air pipes to high for the save all size. STB save all to low. FWD anchor light with improper glass. Fairland roller damaged. Block shall on STB derrick guy holed. Due to a grounding the propeller, rudder and steering gear are severely damaged. 22/01/2007 SORMOVSKIY- Russia Volga - Neva Russian Detained for 10 days. 3003 Maritime 12 recorded deficiencies. Koper Saint Register of Hull on PS corroded General cargo Petersburg Shipping through. SOPEP not up to date. MOB expired. 7945869 Russia Horn inoperative. Chart missing. Sanitary dirty. 2491 Galley dirty. Galley hood filters missing. Provision store room dirty. Food provisions insufficient. Crew without personal protective equipment. ISM maintenance of ship and equipment failed. 23/01/2007 ALTAIR Panama Bnavi ship Registro Detained for 2 days. management Italiano Navale 19 recorded deficiencies. Koper General cargo OFE certificate and 15 Marina di ppm calibration 7813602 Carrara certificate missing. Two red lights for ship not 16.325 Italy under command with improper glasses. Alleyway bulkhead corroded through. Store room door corroded through. Galley bulkhead corroded through. PS entrance door corroded through. Spare cabin bulkhead corroded through. PS aft bulwark frames corroded through. DBWT 4 sounding pipe corroded through. Hatch way entrance CC4 corroded through. On DG1 and DG3 fuel leaking alarm tank covers not bolted. On all three DGs fuel injection pipes from pump to nozzle not fixed-slack. Additional pipe fitted on OFE outboard line. 15 ppm contain meter not adjusted. Steering gear room air vent corroded through. Air condition improperly fitted on two cabin windows. O PS hull steel protection temporary repaired with concrete. Front bridge bulkhead doubler improperly welded. EFP insufficient pressure. 29/01/2007 GENEROSO Cyprus Giuseppe Registro Detained for 3 days. Pattela Italiano Navale 6 recorded deficiencies. Koper General cargo Pipe which connect fuel Venice tank to boiler burner 9359985 made of rubber. ME fuel Italy leaking alarm 3144 inoperative. On DG No 2 protection missing. ER bilge dirty. Ship is using overflow tank not recorded in IOPP certificate. Improper installation of air conditions on cabin bulkheads. 06/02/2007 EL HUSSAIN Libya North African International Detained for 7 days. Company Survey Bureau 11 recorded deficiencies. Koper General cargo IAPC missing. Funnel Misurata damper sized. ER air 7915199 vent corroded through. Libya Oil tank air pipe corroded 7533 through. Mess room bulkhead corroded through. Hydraulic pipes on hatch covers leaking. EG inoperative. ME leaking alarm inoperative. DGs leaking alarms inoperative. ER bilges dirty. OFE inoperative. 26/02/2007 SVETLA Comoros Ka-Trans Shipping Detained for 10 days. Navigation Register of 26 recorded deficiencies. Koper General cargo Ukraine Personal equipment Odessa expired. Charts missing. 7702322 Crew does not wear Ukraine personal protective 945 equipment. Galley ventilation inoperative. Galley owen inoperative. Toilets in bad condition. Heating inoperative. Fuel tank holed. FP air pipe corroded through. Fire line girder cracked. Entrance bulkhead corroded through. Deck beams corroded through. Hatch coaming cracked. Hold frames bent. Railing damaged. Frame bracket corroded through. Hatch covers corroded through. ME air vent corroded through. Fire fighting equipment not as required. Rubber gaskets in bad condition. FWD entrance in hold leaking. Side ballast tank in bad condition. ISM preparedness failed. ISM maintenance failed. 28/02/2007 SVYATAYA Georgia Fedcom Russian Detained for 3 days. MAIYA shipping Maritime 9 recorded deficiencies. Koper Register of Captain deck entrance Bulk carrier Mariupol Shipping corroded through. ER air vent corroded through. 7361128 Ukraine Air condition room air vent corroded through. 31111 Hold 5 air vent corroded through. Hold 3 ail vent corroded through. Hold 1 air vent corroded through. Chief officer cabin window glass cracked. ME leaking alarm inoperative. 07/03/2007 SHKODRA Sierra Albartin Dromon Detained for 2 days. Leone Shipping 4 recorded deficiencies. Koper General cargo Magnetic compass with Durres air bubbles. ER fire 7005140 sensors inoperative. Albania QCV inoperative. ER 1492 door for spare parts not bolted. 10/03/2007 HAJ YAMAK Georgia San Nicola Black Sea Detained for 5 days. Ship Bureau of 20 recorded deficiencies. Koper Bulk carrier management Shipping Hold water level indicator missing. Radio room air 7312684 Durres vent corroded through. Funnel door corroded 3809 Albania through. Cabin bulk head corroded through. Air condition room air vent corroded through. PS entrance door corroded through. Chief eng. cabin bulkhead corroded through. Stern anchor light with improper glass. Stern mooring winches base corroded through. On PS hatch coaming No 5 one frame corroded through. On PS hatch coaming No 3 three frames corroded through. On FCSL anchor light missing. On Oil tanks gauges made of plastic. On settling tank QCV blocked with bolts. Water pipes temporary repaired. In ER four possible illegal discharge fitted. Crew does not use personal protective equipment. Frames on hatch covers on hold 1 and 3 corroded through. ISM maintenance failed. 12/04/2007 ROSE - S Cambodia Seawise Global Marine Detained for 3 days. Shipping Bureau 6 recorded deficiencies. Koper General cargo Company address on Tripoli DOC and SMC not the 7528556 same. Original SMC not Lebanon on board. Original ISPS 3622 not on board. Hydraulic tank air pipe ball protection corroded through. On FCSL bell missing. ME fuel leaking alarm inoperative. 26/04/2007 MALBORK Georgia Ka-Trans Shipping Detained for 8 days. navigation Register of 17 recorded deficiencies. kOPER Bulk carrier Ukraine Computer room air vent Odessa corroded through. 7725520 Battery room bulkhead Ukraine corroded through. Funnel 3.127 corroded through. Funnel damper sized. Aft bulkhead on master deck corroded through. Cabin bulkhead on boat deck corroded through. Over door air vent damper missing. Front bridge bulkhead corroded through. Hatch covers frames corroded through. Galley bulkhead corroded through. Front bridge bulkhead (watch room) corroded through. On FCSL bell missing. Hatch covers frames corroded through. Air pipe on tank 2a corroded through. Outboard valve from removed OFE can be used as illegal discharge. Lifeboat engine throttle valve inoperative. ISM- emergency preparedness. 03/05/2007 DECURION Argentina Maruba Sca Nippon Kaiji Detained for 7 days. Kyokai 11 recorded deficiencies. Koper Bulk carrier Buenos Aires IAPC missing. Store air vent corroded through. 8302545 Argentina On boat deck save all corroded through. ER 34.839 skylight corroded through. Steering gear room air vent corroded through. Steering gear room hatchway cover corroded through. Standard discharge connection improper. Entrance hatchway to hold six corroded through. Three hatch coaming frames not as required. FO settling tank QCV inoperative. FO service tank QCV inoperative. 29/05/2007 CAPELLA St. Firma Briz Russian Detained for 3 days. Vincent & Ltd. Maritime 12 recorded deficiencies. Koper General cargo Grenadine Register of Stern anchor light glass St. Shipping cracked. Four frame 7612412 Petersburg angles on aft hold 2 bulkheads damaged and 2349 Russia detached. In hold 2 aft ladder bent. In hold 2 door on aft bulkhead not bolted. On hold 2 hatch covers frames corroded through. Alarm for navigational lights inoperative. On OFE out board line illegal by pass line installed. On OFE outboard line two valves not as required. Fuel gauge on tank 30 fuel leaking. ER fire door blocked with wood board. ER crew does not use safety shoes. OFE inoperative. 21/06/2007 NIKA St. Nika Shipping International Detained for 7 days. Vincent & Co. Naval Survey 24 recorded deficiencies. Koper General cargo Grenadine Bureau IAPP certificate missing. Rijeka DOC annual missing. 7411600 Certificate for CO2 Croatia system expired. 2.570 Certificate for all BA and EBD expired. Wheelhouse window glass cracked. Bridge toilet inoperative. Periscope mirror for steering compass unusable. Main magnetic compass with air bubbles. Batteries for two way communication missing. Door on CO2 system room corroded through. Emergency light on lifeboat deck sized. Both ER air vents dampers sized. Aft cargo winch hydraulic oil leaking. On PS hatch coaming 7 frames cracked. Chain locker bulkhead corroded through. In FCSL 2 frames bent. Gauges on fuel tanks blocked in open position. EFP insufficient pressure. One fire hose leaking. QCV on fuel tanks inoperative. Cooling water leaking on cylinders 1&3. On ME fuel pipe leaking. OFE outboard line illegal discharge fitted. ISM failed. 17/07/2007 RAWAN Georgia Uni-Marine International Detained for 17 days. Management Register of 19 recorded deficiencies. Koper General cargo Shipping Funnel dampers sized. Tartous Funnel corroded through. 7123502 Funnel door corroded Syria through. Battery room air 1.465 vent corroded through. Magnetic compass with air bubble. Chief mate cabin bulkhead corroded through. Windlass chain guide damaged. Port side frames corroded through. Starboard side frames corroded through. Top side tank bulkhead cracked. Air pipe on DB3 corroded through. Saloon bulkhead corroded through. Second engineer cabin bulkhead corroded through. Captain cabin bulkhead corroded through. Chief engineer cabin bulkhead corroded through. Hold 2 frames corroded through. Hold 2 frames bent. 25/07/2007 AMITIE Georgia Barhoum Hellenic Detained for 5 days. Maritime Co. Register of 28 recorded deficiencies. Koper General cargo Shipping PS galley air vent Tartous corroded through. STB 7607429 galley air vent corroded Syria through. PS gyro 1.939 repeater differ 20° and STB gyro repeater differ 5° from main gyro compass. In main magnetic compass liquid missing. Battery room bulkhead corroded through. Chief mate cabin bulkhead corroded through. Captain cabin bulkhead corroded through. Second engineer cabin bulkhead corroded through. Cook cabin bulkhead corroded through. Bilge/sludge drawing not as required. STB hold air vent corroded through. Fuel/sludge save all corroded through. PS BW2 air pipe corroded through. Hatch covers frames corroded through. Anchor ball to small. In FCSL five consecutive frames bent. In FCSL deck corroded through. STB BW1 air pipe corroded through. All four hatch coaming brackets damaged. In hold several frames bent. In hold six frames corroded through. Two tripping plates between frames corroded through. On funnel fire damper sized. One stern light with glass cracked. On Paint room air vent missing. Possible illegal discharge flange fitted. PS FW air pipe ball protection corroded through. ISM failed. 03/09/2007 ODINBAY Turkey Odin Ship Nippon Kaiji Detained for 3 days. Management Kyokai 13 recorded deficiencies. Koper General cargo Monkey deck corroded Istanbul through. Two red lights 7916727 for ship not under Turkey command with improper 8.239 glasses. ER sky light gasket holder corroded through. Stern anchor light glass cracked. On hold 1 STB hatch coaming corner reinforcement corroded through. FCSL air vent corroded through. Several valves on tanks air pipes sized. ME dirty. On OFE output line illegal discharge flange fitted. OFE inoperative outlet line dirty with oil. EFP throttle valve inoperative. On lifeboat engine throttle valve inoperative. ISM maintenance failed. 05/09/2007 DOLUNAY Turkey Aleria Turkish Lloyd Detained for 2 days. Denizcilik 10 recorded deficiencies. Koper General cargo LL certificate expired. Istanbul Rescue boat deflated. 7407245 Funnel corroded through. Turkey PS ER air vent corroded 996 through. STB ER air vent damper sized. BL1 air pipes ball protection corroded through. In EFP room 3 frame corners bent. In front of main electric panel antistatic carpet missing. On ME oil vapours pipe broken. ISM certification failed. 06/09/2007 DOCTOR RAMI Georgia Seamar Polski Rejster Detained for 8 days. Shipping Statkow 40 recorded deficiencies. Koper General cargo Charts 1471 and 1440 Tartous not up to date. Gyro 6815811 repeaters not Syria synchronised with main 2.752 gyro. In main magnetic compass liquid missing. Two red lights for ship not under command with improper glasses. Both ER air vents corroded through. Deck behind funnel over ER corroded through in several places. Air condition room bulkhead corroded through. Boat deck over galley corroded through in several places. Safety valve on auxiliary boiler disconnected. Galley store bulkhead corroded through. In hold No 4 STB 4 gusset plates corroded through. In hold No 4 PS 3 gusset plates corroded through. In hold 4 five frames corroded through. In hold 4 two horizontal frame supports corroded through. Poop deck corroded through in 3 places. On mast house 1 cargo winch bed plate corroded through on 1 bed plate damaged. Front bridge bulkhead corroded through. Both chain pipes corroded through. Windlass frame corroded through. FCSL hatchway cover corroded through. On FCSL bell missing. On hold 1 hatch cover gasket corroded through. On hold 1 hatch cover frame corroded through. In hold 1 four gusset plates corroded through. In hold 1 horizontal frame support corroded through. Spare cabin bulkhead corroded through. Standard discharge connection improper dimension and without slots. On ME cylinder No 5 cooling water leaking. ME fuel leaking alarm inoperative. On auxiliary engine No 1 fuel leaking alarm inoperative. ME, auxiliary engine and ER bilge dirty. Top of the tank of the boiler water tank corroded through. Possible illegal discharge line connected to boiler water tank. On manhole cover of boiler water tank valve fitted. On air compressor protection missing. On deep tank manhole cover valve fitted. Auxiliary engine No3 inoperative. Ship's hospital improperly used. Abandon drill failed. ISM maintenance of ship failed. 11/09/2007 NIKA St Vincent Nika Shipping International Detained for 7 days. & Naval Survey 15 recorded deficiencies. Koper General cargo Grenadine Rijeka Bureau In hold top of the tank damaged. 3 crew 7411600 Croatia member missing. Crew members without 1575 medical examination. EFP inoperative. Rescue boat engine inoperative. ER fire sensors inoperative. Self igniting lights inoperative. Muster list incomplete. Echo sounder inoperative. Magnetic compass with air bubbles. Notice of mariners not up to date. Ventilation in galley dirty. Food store dirty. ISM maintenance failed. ISM documentation incomplete. 04/10/2007 LADY RASHA Georgia Uni Marine Maritime Lloyd Detained for 6 days. Management 20 recorded deficiencies. Koper General cargo On PS hull scuttle glass Tartous cracked. Chart room 7223041 bulkhead corroded 1.777 Syria through. Deck over ER corroded through. ER skylight cover corroded through. Top of the ER air vent corroded through. The size of magnetic compass improper, blocked gimble. Monkey deck over ER corroded through. Aft derrick on hold 1 cracked. On hatch coaming of hold 1 STB one frame cracked and one corroded through. PS chain pipe corroded through. In hold 1 FWD 12 frames corroded through. In hold 1 FWD four frames face reinforcements bent. In hold 1 FWD four face reinforcements cracked. STB chain stopper disconnected. FWD ladder in hold 1 detached. On hold 2 PS hatch coaming frame cracked. Compressor cooling water pipe temporary repaired. Grey water pipe in ER temporary repaired. Possible illegal discharge fitted on OWS outlet pipe. ISM maintenance of ship and equipment failed. 05/10/2007 GOLDEN Panama Transocean International Detained for 18 days. GEMINI Services Register of 32 recorded deficiencies. Koper Shipping Hull holed. Frames General cargo Bucharest corroded through. Hold 1 air vent corroded 8314081 Romania through. Funnel corroded through. Funnel air vent 3.506 covers missing. ER skylight not ready to use. Emergency fire pump insufficient pressure. Abandon drill failed. IAPP certificate expired. Emergency preparedness failed. Safety radio certificate expired. Crew certificates not endorsed. SOPEP not updated. HRU expired. Self igniting lights inoperative. Notice of mariners expired. Bell missing. Gasket on hatch covers bad. Limit switches on davits inoperative. Personal protective equipment missing. Toilets, showers dirty. Food store dirty. Cold room dirty. Alarm in cold room missing. Air condition system inoperative. Two way VHF spare batteries missing. ER dirty. ER floors not fixed. Steering gear room dirty. ISM Maintenance of ship and equipment failed. 08/10/2007 IRAN BAGHERI Iran Iran Shipping Lloyds Detained for 6 days. Line Register 12 recorded deficiencies. Koper General cargo Side scuttle glass on hull Tehran cracked. Magnetic 7428811 compass gimble not Iran fixed. Funnel corroded 13.914 through. Stern anchor light improper glass. Front bridge bulkhead corroded through in several places. Hot well tank leaking. Possible illegal discharge fitted on OFE outboard line. OFE inoperative. Emergency generator inoperative. Emergency light inoperative. Emergency preparedness failed. ISM maintenance of ship and equipment failed. 12/10/2007 IRINA Georgia Mihei International Detained for 4 days. Shipping & Register of 9 recorded deficiencies. Koper General cargo Trade Shipping In wheelhouse one clear view window inoperative. 7906693 Constanta ER tank air pipe corroded through. Front 2.075 Romania bridge bulkhead corroded through in several places. On bilge tank gauge missing. On ME cylinder 1 & 8 cooling water leaking. Sound alarm on ME fuel leaking alarm inoperative. Possible illegal discharge fitted on STB hull. Emergency fire pump inoperative. ISM Emergency preparedness failed. 15/10/2007 AMARAN Panama Martinoli & C Germanischer Detained for 3 days. Lloyd 16 recorded deficiencies. Koper Chemical tanker Genova No information of MEI. PS lifeboat main rail 8128779 Italy cracked. Hospital air vent cover inner gasket holder 2.690 corroded through. Accommodation air vent cover inner gasket holder corroded through. On PS deck eye washer inoperative. Standard discharge connection improper flanges. Safety locker door inner gasket holder corroded through. Pump room air vent fans not earthed and watertight. One hydrophore pump not in place. Auxiliary boiler inoperative. On ME all jacketed high pressure lines disconnected. ME fuel leaking alarm inoperative. Abandon ship drill failed. Maintenance of ship and equipment failed. Emergency preparedness failed. Obsolete OWS flange to be blinded. 17/10/2007 GHAREEB S Comoros Safe Fleet Guardian Detained for 7 days. Maritime Co. Bureau of 18 recorded deficiencies. Koper General cargo Shipping CSR missing. Master Tartous toilet bulkhead corroded 6823155 through. Standard Syria discharge connection 993 improper. In rescue boat fuel tank missing. Rescue boat engine inoperative. ER door corroded through. Shower air vent corroded through. ER air vent cover heavily bent. On windlass both chain guide detached. On FP sounding pipe cover plug missing. Anchor ball improper size. On EDG fuel tank QCV inoperative. Starter on EDG inoperative. Galley side scuttle glass cracked. Grey water pipe in steering room temporary repaired. Air condition cables improperly pass through the bulkheads. Maintenance of ship and equipment. ISM records keeping not as required. 19/10/2007 NIMEH - 1 Panama Silver Star Lloyd register Detained for 6 days. Maritime 15 recorded deficiencies. Koper General cargo DOC not annually Lattakia endorsed. Wheelhouse 7712028 bulkhead corroded Syria through. Monkey deck 6.000 corroded through. STB gyro repeater 30°diffierence that main. Galley air vent airtight. STB windlass frame corroded through. On FCSL bell clapper missing. FWD hold air vents dampers sized. On rope hatchway cover 4 dogs missing. On ME and DG skylight cover corroded through. In ER fire sensors covered with plastic. On OFE outboard line and sludge line temporary repaired with rubber. Rescue boat engine inoperative. ISM documentation failed. Emergency preparedness lack of training. 26/10/2007 GREEN Panama Alemar S.r.l. Isthmus Detained for 65 days. FLOWER Bureau of 55 recorded deficiencies. Koper Napoli Shipping AIS inoperative. Last General cargo entry in ORB made 21. Italy May 2006. In 7397971 wheelhouse clear view windows missing. 1.628 Wheelhouse bulkheads corroded through. Wheelhouse window glass cracked. On owner's cabin window glass cracked. Master's cabin window glass cracked. Chief engineer's cabin window glass cracked. All three gyro repeaters inoperative. Main and steering magnetic compass inoperative. PS D- corrector broken. Funnel corroded through. Funnel air vent covers corroded through. Funnel door corroded through. Both lifeboats full of water. Navigational lights alarm inoperative. Emergency generator inoperative. ER emergency lights battery inoperative. Alleyway bulkhead corroded through. ER air vent corroded through. Galley air vent corroded through. Galley bulkhead corroded through. PS rope store frames corroded through. Crew mess room bulkhead corroded through. Insufficient quantity of food and water on board. PS WT2 air pipe corroded through. PS WT1 air pipe corroded through. FP bulkhead corroded through. STB wing tank heavy leakage. Hatch covers corroded through. Severe communication between DB tanks. Crew are not equipped with personal protective equipment. FCSL deck corroded through. STB WT1 air pipe corroded through. Both AFT hold air vents corroded through. Three cabin toilets flooded. Ship's toilets without flushing waters. All grey water pipes corroded through. On DG 1 fuel leaking. Fuel tanks QCVs inoperative. Possible illegal discharge line fitted. Sludge tank connected with bilge pump. In ER main fire line temporary repaired. Emergency fire pump inoperative. Fuel transfer line made of rubber. ME fuel leaking alarm inoperative. ME rocker arm lubrication pump inoperative. ER general alarm inoperative. PS lifeboat davit base corroded through. Both lifeboats can not be lowered. Oil bilge water discharged through rubber line instead fixed sludge line. Abandon drill failed. Maintenance of ship and equipment failed. Emergency preparedness failed. 12/11/2007 ASKANIA Antilles Intertrad Germanischer Detained for 3 days. Shipping Lloyd 4 recorded deficiencies. Koper Ro-ro cargo ship IAPP certificate missing. Livorno Hatch covers gaskets not 8209690 as required. Ropes in Italy bad condition. ISM 4.291 documentation not as required. 13/11/2007 SOUBHI - J Syria Dolphin Lloyd's Detained for 5 days. Shipping Co. register 26 recorded deficiencies. Koper General cargo OCM and OFE Lattakia certificates missing. CSR 7427609 certificate missing. Chart Syria 1471 not up to date. 1.910 Wheelhouse bulkhead corroded through. Chart room bulkhead corroded through. Funnel corroded through. Galley air vent corroded through. Generator room air vent cover corroded through. In hold ST one frame detached from hull. In hold several frames bent. In hold top of the tank 5 corroded through. STB tank 3 air pipe corroded through. In FCSL port 2 frame corners bent. In FCSL STB 4 consecutive frames bent. In FCSL STB 2 side reinforcement plates detached and bent. Both chain pipes corroded through. FP and DT air pipes ball protections corroded through. Store air vent cover corroded through. Drum used for DGs fuel tank. EDG inoperative. ME turbine casing temporary repaired with plastic steel. ME cooling water inlet and outlet pipes temporary repaired. Air condition cables improperly installed through the saloon bulkhead. ISM documentation failed. Maintenance of ship and equipment failed. Possible illegal discharge on OFE outboard line. 14/11/2007 AL BUSHRA Libya Phoenicia Guardian Detained for 5 days. Maritime Co. Bureau of 16 recorded deficiencies. Koper General cargo Shipping IAPP certificate missing. Tartous On standard discharge 7007071 connection flange Syria additional pipe fitted. All 1.944 navigational lights glasses improper. ON FCSL bell to small. Wheelhouse bulkheads corroded through. Rescue boat deflated. Improper perforation of air condition cables through the bulkheads. Galley bulkhead corroded through. n port generator protection missing. ER and steering gear room bilge to be dried and cleaned. Cylinder No 2 on ME cooling water leaking. Rubber pipe connected on bilge pump line. From daily and settling tanks fuel lines connected to the OFE. OFE pump used for pumping contents of holding tank to shore. ME fuel leaking alarm inoperative. Maintenance of ship and equipment failed. 28/11/2007 NIKA St. Nika Shipping International Detained for 10 days. Vincent & Naval Survey 7 recorded deficiencies. Koper General cargo Grenadine Rijeka Bureau Chief mate certificate s endorsement missing. 7411600 Croatia Freeboard marks not readable. Nautical 1.575 publications not up to date. Bulkhead on FCSL corroded through. in hold deck beam corroded through. Bulkhead on ballast tank TST 1 corroded through. ISM maintenance of ship and equipment failed. 18/12/2007 ALADA Malta Alloceans Lloyd's Detained for 2 days. Shipping Co. Register 14 recorded deficiencies. Koper Bulk carrier Battery room bulkhead Athens corroded through. 8100882 Satellite EPIRB Greece inoperative. Magnetic 22.076 compass with air bubbles. Air pipe for ship's horn corroded through. Ball protection of void space air pipe corroded through. ER air vent corroded through. Ball protection of ER tank air pipe corroded through. Standard discharge connection flange improper. STB chain pipe corroded through. Deck between hold 4 and 5 buckled. EFP insufficient pressure. FO tank P4 air pipe corroded through. In steering gear room 6 consecutive frame corners bent. On pipe between purifier sludge and bilge sludge tank illegal connection pipe fitted. 25/12/2007 JULIANA Panama Mega International Detained for 5 days. Shipping co. Register of 20 recorded deficiencies. Koper General cargo Shipping One OW missing. In Piraeus wheelhouse view screen 7387201 window missing. Greece Magnetic compass do 1.900 not move freely in gimble. Front bridge corroded through. PS ER air vent cover corroded through. Stern anchor light glass cracked. Tank 2S air pipe corroded through. FWD anchor light missing. In FCSL 3 frame corners bent. In hold 1 several frames bent. In hold 1 several frames, beams and gusset plates corroded through. Tank 1S air pipe corroded through. Tank 2P air pipe corroded through. Tank 3P air pipe corroded through. Tank 4P air pipe corroded through. Tank 5P air pipe corroded through. OFE inoperative. ME fuel leaking alarm inoperative. ISM lack of training. ISM maintenance failed. 27/10/2007 SLAVUTICH- 10 Monteneg Nimont Ltd. Montenegro Detained for 5 days. ro 35 recorded deficiencies. Koper General cargo Bar In minimum safe manning certificate 8841498 Montenegro master missing. In IOPP certificate bilge tank 2.193 recorded twice. Sludge and bilge tanks are full. Main magnetic compass missing. Spare batteries for 2 way VHF expired. Radio room bulkhead corroded through. ER skylight corroded through. PS life raft improperly lashed. Funnel corroded through. EDG room bulkhead corroded through. Self igniting lights inoperative. Boat swain cabin bulkhead corroded through. Sewage discharge connection improper. All navigational lights with improper lights. Main fire line temporary repaired. Chief engineer cabin corroded through. Front bridge bulkhead corroded through. Chief engineer cabin window glass cracked. Seaman cabin bulkhead glass cracked. STB entrance door corroded through. On standard discharge connection additional pipe fitted. Spare cabin bulkhead corroded through. FCSL deck corroded through. Eight hatch coaming frames cracked. On FCSL bell missing. In tank 2C five deck support pillars and one beam corroded through. In tank 4 PS eleven frames and 2 beams corroded through. In tank 5 STB two deck support pillars cracked and corroded through. In tank 6 STB two deck supporting pillars corroded through. On PS ME jacketed lines disconnected. On both main engines fuel leaking alarms inoperative. ER bilge full of DO. QCV on fuel tank blocked with wire. ER fire sensors inoperative. ISM maintenance of ship and equipment failed. </p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    23 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us