3.1 4500 Classic Configuration Record Sheet

3.1 4500 Classic Configuration Record Sheet

<p> 3.1 4500 Classic Configuration Record Sheet</p><p>Keep a record Enter the value or selection for each prompt on this sheet so you will have a record of how your recorder was configured.</p><p>Group Function Value or Factory Group Function Value or Factory Prompt prompt Selection Setting Prompt prompt Selection Setting</p><p>INPUT 1 DECIMAL ______XXX.X TOTAL 2 (Value) ______E0 GAL UNITS ______DEGF RSET TOT ______NO ENGUNITS ______— TOTAL 2 ______DISABL IN1 TYPE ______100PT TOTAL EU ______GAL XMITTER ______LINEAR RATE ______SECOND IN1 HI ______900 SCALER ______1 IN1 LO ______-300 RSETABLE ______NO CUTOFF 1 ______0 INPTCOMP ______0 INHIBIT ______NONE FILTER 1 ______0 CONTROL1 ______ENABLE BURNOUT ______UP CONTROL 1 PID SETS ______1ONLY EMISSIV ______.01 SW VALUE ______0.0 INPUT 2 DECIMAL ______XXX.X SP SOURC ______1LOCAL UNITS ______DEGF RATIO ______1.0 BIAS ______0 ENGUNITS ______— SP TRACK ______NONE IN2 TYPE ______100PT POWER UP ______MANUAL XMITTER ______LINEAR SPHILIM ______LAST IN2 HI ______900 SPLOLIM ______0 IN2 LO ______-300 ACTION ______REVRSE CUTOFF 2 ______0 OUTHILIM ______100.0 INPTCOMP ______0 OUTLOLIM ______0 FILTER 2 ______0 DROPOFF ______0.0 BURNOUT ______UP DEADBAND ______2.0 EMISSIV ______.01 OUT HYST ______0.5 FAILSAFE ______50 PEN 1 PEN1IN ______INPUT1 REM SW ______NONE CHART1HI ______302.0 MAN KEY ______ENABLE CHART1LO ______292.0 PBorGAIN ______GAIN PEN1ON ______91.0 MINorRPM ______MIN PEN1OFF ______93.0 CONT1ALG ______PIDA OUT1ALG ______CURRENT PEN 2 PEN2IN ______INPUT2 4-20 RNG ______50PCT CHART2HI ______302.0 CHART2LO ______292.0 PEN2ON ______91.0 PEN2OFF ______93.0</p><p>CHART CHRTSPD ______XHR HOUR/REV ______12 LINEARIZ ______—</p><p>TOTAL 1 (Value) ______E0 GAL RSET TOT ______NO TOTAL 1 ______DISABL TOTAL EU ______GAL RATE ______SECOND SCALER ______1 RSETABLE ______No</p><p>INHIBIT ______NONE</p><p>Error! Unknown document property name. 4500 Classic Configuration Record Sheet</p><p>Group Function Value or Factory Group Function Value or Factory Prompt prompt Selection Setting Prompt prompt Selection Setting</p><p>CONTROL 2 CONTROL2 ______ENABLE TUNING 2 FUZZY ______DISABL PID SETS ______1ONLY ACCUTUNE ______DISABL SW VALUE ______0.0 AT ERR Read only — SP SOURC ______1LOCAL PROP BD ______1.0 RATIO ______1.0 or BIAS ______0 GAIN ______1.0 SP TRACK ______NONE RATE MIN ______0.00 POWER UP ______MANUAL RSET MIN ______1.0 SP HILIM ______500 or SP LOLIM ______0 RSET RPM ______1.0 ACTION ______REVRSE MAN RSET ______0.0 OUTHILIM ______100.0 CYCSEC ______20.0 OUTLOLIM ______0 PROP BD2 ______1.0 DROPOFF ______0.0 or DEADBAND ______2.0 GAIN 2 ______1.0 OUT HYST ______0.5 RATE2MIN ______0.00 FAILSAFE ______50 RSET2MIN ______1.0 REM SW2 ______NONE or MAN KEY ______ENABLE RSET2RPM ______1.0 PBorGAIN ______GAIN CYC2SEC ______20.0 MINorRPM ______MIN CONT2ALG ______PIDA SP RAMP1 SP RAMP ______DISABL OUT2ALG ______CURRENT TIME MIN ______0 4-20 RNG ______50PCT FINAL SP ______100.0 SP RATE ______DISABL TUNING 1 FUZZY ______DISABL EU/HR UP ______— ACCUTUNE ______DISABL EU/HR DN ______— AT ERR Read only SP PROG ______DISABL PROP BD ______1.0 RECYCLES ______— or SOAK DEV ______— GAIN ______1.0 PROFILE ______— RATE MIN ______0.00 STATE ______— RSET MIN ______1.0 RECOVERY ______— or PROG END ______— RSET RPM ______1.0 MAN RSET ______0.0 SP RAMP2 SP RAMP ______DISABL CYCSEC ______20.0 TIME MIN ______0 PROP BD2 ______1.0 FINAL SP ______100.0 or SP RATE ______— GAIN 2 ______1.0 EU/HR UP ______— RATE2MIN ______0.00 EU/HR DN ______— RSET2MIN ______1.0 SP PROG ______DISABL or RECYCLES ______— RSET2RPM ______1.0 SOAK DEV ______— CYC2SEC ______20.0 PROFILE ______— STATE ______— RECOVERY ______— PROG END ______—</p><p>SPP SEGS PRx STRT ______— PRx END ______— RAMPUNIT ______— SYNC 1+2 ______—</p><p>SPPSEGS SEGxRAMP ______— SEGx SP ______— SEGxTIME ______—</p><p>SPP EVNT SEGx EV ______—</p><p>Error! Unknown document property name. 4500 Classic Configuration Record Sheet</p><p>Group Function Value or Factory Group Function Value or Factory Prompt prompt Selection Setting Prompt prompt Selection Setting</p><p>TIMER TIMER ______DISABL ALARM 5 A5S1 VAL ______90 PERIOD ______0:01 A5S2 VAL ______95 START ______KEY A5S1TYPE ______INPUT1 LDISPLAY ______TREM A5S2TYPE ______INPUT1 RESET ______KEY A5S1 H L ______LO __ A5S1SCAL ______1 ONTIME ______A5S2 H L ______HI INCRMENT MIN A5S2SCAL ______1 ______AL5 HYST ______0.1</p><p>ALARM 6 A6S1 VAL ______90 A6S2 VAL ______95 ______A6S1TYPE ______INPUT1 ALARM 1 A1S1 VAL 90 A6S2TYPE ______INPUT1 ______A1S2 VAL 95 A6S1 H L ______LO ______A1S1TYPE INPUT1 A6S1SCAL ______1 ______A1S2TYPE INPUT1 A6S2 H L ______HI ______A1S1 H L LO A6S2SCAL ______1 ______A1S1SCAL 1 AL6 HYST ______0.1 A1S2 H L ______HI A1S2SCAL ______1 AUX OUT AUX OUT ______DISABL AL1 HYST ______0.1 4 mA VAL ______0.0 ______20mA VAL ______100.0 ALARM 2 A2S1 VAL 90 ______A2S2 VAL 95 AUX OUT2 AUX OUT2 ______DISABL ______A2S1TYPE INPUT1 4 mA VAL2 ______0.0 ______A2S2TYPE INPUT1 20mA VAL2 ______100.0 ______A2S1 H L LO ______A2S1SCAL 1 AUX OUT3 AUX OUT3 ______DISABL ______A2S2 H L HI 4 mA VAL3 ______0.0 ______A2S2SCAL 1 20mA VAL3 ______100.0 AL2 HYST ______0.1 ______COMM ComSTATE ______DISABL ALARM 3 A3S1 VAL 90 Com ADDR ______1 ______A3S2 VAL 95 BAUD ______9600 ______A3S1TYPE INPUT1 XMT DLAY ______NONE A3S2TYPE ______INPUT1 A3S1 H L ______LO OPTIONS REJ FREQ ______60 A3S1SCAL ______1 HF REJ ______ENABLE A3S2 H L ______HI RELHUMID ______NO A3S2SCAL ______1 ATMPRES ______— AL3 HYST 0.1 DEVIATION ______NONE ______DEVSETPT ______0 ______ALARM 4 A4S1 VAL 90 SCROLL ______NONE ______A4S2 VAL 95 GRANDTOT ______DISABL A4S1TYPE ______INPUT1 A4S2TYPE ______INPUT1 LOCKOUT PASSWORD ______XXXX A4S1 H L ______LO LOCKOUT ______CALIB A4S1SCAL ______1 CHANGE ______XXXX A4S2 H L ______HI A4S2SCAL ______1 AL4 HYST ______0.1</p><p>Error! Unknown document property name. </p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    4 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us