
<p>ANNEX A - PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) </p><p>(This annex is part of this Standard and is required for its use.)</p><p>BACnet Protocol Implementation Conformance Statement</p><p>Date: ___4/NOV/2009______Vendor Name: Samsung Heavy Industries co., ltd. Product Name: SSAS Product Model Number: SSAS-Pro, SSAS-Master Application Software Version: __1.1.8___ Firmware Revision: __1_____ BACnet Protocol Revision: __4______</p><p>Product Description: _ The SSAS-Master is a native BACnet/IP protocol controller with a flexible and expandable Input/Output through the use of Input/Output Units. It has a serial port which may used to a communicate with MS/TP controller devices. _The SSAS-Master is also a BACnet protocol router and BACnet/IP Broadcast Management Device(BBMD).</p><p>BACnet Standardized Device Profile (Annex L):</p><p> BACnet Operator Workstation (B-OWS) BACnet Building Controller (B-BC) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Sensor (B-SS) BACnet Smart Actuator (B-SA)</p><p>List all BACnet Interoperability Building Blocks Supported (Annex K): ______DS-RP-A, DS-RP-B, DS-RPM-A, DS-RPM-B, DS-WP-A, DS-WP-B, DS-WPM-B AE-N-I-B, AE-ACK-B, AE-ESUM-B, AE-INFO-B, SCHED-I-B, SCHED-E-B, T-VMT-I-B, T-ATR-B, DM-DDB-A, DM-DDB-B, DM-DOB-A, DM-DOB-B, DM-DCC-B, DM-TS-B, DM-UTC-B, DM-RD-B, DM-BR-B, DM-OCD-B </p><p>Segmentation Capability:</p><p> Segmented requests supported Window Size 10 Segmented responses supported Window Size 10 </p><p>Standard Object Types Supported:</p><p>An object type is supported if it may be present in the device. For each standard Object Type supported provide the following data: 1) Whether objects of this type are dynamically creatable using the CreateObject service 2) Whether objects of this type are dynamically deletable using the DeleteObject service 3) List of the optional properties supported 4) List of all properties that are writable where not otherwise required by this standard 5) List of proprietary properties and for each its property identifier, datatype, and meaning 6) List of any property range restrictions Standard Object Types Supported</p><p>Supported Creatable Deletable Analog Input Ⅹ Analog Output Ⅹ Analog Value Ⅹ Ⅹ Ⅹ Binary Input Ⅹ Binary Output Ⅹ Binary Value Ⅹ Ⅹ Ⅹ Calendar Ⅹ Device Ⅹ Event Ⅹ Enrollment Notification Ⅹ Class Schedule Ⅹ Trend Log Ⅹ</p><p>* Object instans of all suportted object types are able to be created and deleted using Gitos-BACMaster. Object Types and Properties Supported</p><p>Descriptions are limited to 132 characters and object names are restricted to 32 characters. In device objects, vendor names and locations are limited to 32 characters, locations are permitted to 64 characters, and firmware revisions are limited to 100 characters. All other properties of input and output objects are permitted to 64 characters.</p><p>1. Analog Input</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name</p><p>Object_Type</p><p>Present_Value Ⅹ</p><p>Status_Flags</p><p>Event_State</p><p>Out_Of_Service Ⅹ</p><p>Units Ⅹ</p><p>Cov_Increment Ⅹ</p><p>Description Ⅹ Ⅹ</p><p>2. Analog Output</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name</p><p>Object_Type</p><p>Present_Value Ⅹ</p><p>Status_Flags</p><p>Event_State</p><p>Out_Of_Service Ⅹ</p><p>Units Ⅹ</p><p>Cov_Increment Ⅹ</p><p>Description Ⅹ Ⅹ</p><p>Priority_Array</p><p>Relinquish_Default Ⅹ 3. Analog Value</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name Ⅹ</p><p>Object_Type</p><p>Present_Value Ⅹ</p><p>Status_Flags</p><p>Event_State</p><p>Out_Of_Service Ⅹ</p><p>Units Ⅹ</p><p>Cov_Increment Ⅹ</p><p>Description Ⅹ Ⅹ</p><p>Priority_Array</p><p>Relinquish_Default Ⅹ</p><p>4. Binary Input</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name</p><p>Object_Type</p><p>Present_Value Ⅹ</p><p>Status_Flags</p><p>Event_State</p><p>Out_Of_Service Ⅹ</p><p>Polarity Ⅹ</p><p>Description Ⅹ Ⅹ</p><p>Active_Text Ⅹ Ⅹ</p><p>Inactive_Text</p><p>5. Binary Output Writable Optional</p><p>Object_Identifier</p><p>Object_Name</p><p>Object_Type</p><p>Present_Value Ⅹ</p><p>Status_Flags</p><p>Event_State</p><p>Out_Of_Service Ⅹ</p><p>Polarity Ⅹ</p><p>Description Ⅹ Ⅹ</p><p>Priority_Array</p><p>Relinquish_Default Ⅹ</p><p>Active_Text Ⅹ Ⅹ</p><p>Inactive_Text</p><p>6. Binary Value</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name Ⅹ</p><p>Object_Type</p><p>Present_Value Ⅹ</p><p>Status_Flags</p><p>Event_State</p><p>Out_Of_Service Ⅹ</p><p>Polarity Ⅹ</p><p>Description Ⅹ Ⅹ</p><p>Priority_Array</p><p>Relinquish_Default Ⅹ</p><p>Active_Text Ⅹ Ⅹ</p><p>Inactive_Text 7. Calendar</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name Ⅹ</p><p>Object_Type</p><p>Present_Value</p><p>Date_List Ⅹ</p><p>Description Ⅹ Ⅹ 8. Device</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name Ⅹ</p><p>Object_Type</p><p>Description Ⅹ Ⅹ</p><p>System_Status</p><p>Vendor_Name</p><p>Vendor_Identifier</p><p>Model_Name</p><p>Firmware_Revision</p><p>Application_Software</p><p>Protocol_Version</p><p>Protocol_Revision</p><p>Protocol_Services_Supported</p><p>Protocol_Object_Types_Supported</p><p>Object_List</p><p>Max_APDU_Length_Accepted</p><p>Segmentation_Supported</p><p>APDU_Timeout Ⅹ</p><p>Number_Of_APDU_Retries Ⅹ</p><p>Device_Address_Binding</p><p>Database_Revision</p><p>Active_COV_Subscriptions</p><p>APDU_Segment_Timeout Ⅹ</p><p>Daylight_Savings_Status Ⅹ</p><p>Last_Restore_Time</p><p>Local_Date</p><p>Local_Time</p><p>Location Ⅹ</p><p>Max_Info_Frames Ⅹ Max_Master Ⅹ</p><p>Max_Segmentation_Accepted</p><p>UTC_Offset</p><p>9. Event Enrollment</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name Ⅹ</p><p>Object_Type</p><p>Description Ⅹ Ⅹ</p><p>Event_Type</p><p>Notify_Type Ⅹ</p><p>Event_Status</p><p>Object_Property_Reference Ⅹ</p><p>Event_Parameters Ⅹ</p><p>Event_Enable Ⅹ</p><p>Acked_Transitions</p><p>Notification_Class Ⅹ</p><p>Event_Time_Stamps 10. Notification Class</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name Ⅹ</p><p>Object_Type</p><p>Description Ⅹ Ⅹ</p><p>Notification_Class</p><p>Priority Ⅹ</p><p>Ack_Required Ⅹ</p><p>Recipient_List Ⅹ</p><p>11. Schedule Object</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name Ⅹ</p><p>Object_Type</p><p>Present_Value Ⅹ</p><p>Description Ⅹ Ⅹ</p><p>Status_Flags</p><p>Schedule_Default Ⅹ</p><p>Out_Of_Service Ⅹ</p><p>List_Of_Object_Property_References Ⅹ</p><p>Priority_For_Writing Ⅹ</p><p>Effective_Period Ⅹ</p><p>Reliability</p><p>Exception_Schedule Ⅹ</p><p>Weekly_Schedule Ⅹ 12. Trend Log</p><p>Writable Optional</p><p>Object_Identifier</p><p>Object_Name Ⅹ</p><p>Object_Type</p><p>Log_Enable Ⅹ</p><p>Description Ⅹ Ⅹ</p><p>Stop_When_Full Ⅹ</p><p>Log_Buffer Ⅹ</p><p>Record_Count Ⅹ</p><p>Total_Record_Count</p><p>Buffer_Size Ⅹ</p><p>Log_Inteval Ⅹ</p><p>Log_Device_Object_Property Ⅹ</p><p>Start_Time Ⅹ</p><p>Stop_Time Ⅹ</p><p>Cov_Resubscription_Interval Ⅹ</p><p>Data Link Layer Options:</p><p> BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7) ANSI/ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ANSI/ATA 878.1, RS-485 ARCNET (Clause 8), baud rate(s) ______ MS/TP master (Clause 9), baud rate(s): 9600/19200/38400 MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: ______ Other: </p><p>Device Address Binding:</p><p>Is static device binding supported? (This is currently necessary for two-way communication with MS/TP slaves and certain other devices.) Yes No</p><p>Networking Options:</p><p> Router, Clause 6 - List all routing configurations – BACnet IP-MS/TP Annex H, BACnet Tunneling Router over IP BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Yes No</p><p>Character Sets Supported:</p><p>Indicating support for multiple character sets does not imply that they can all be supported simultaneously.</p><p> ANSI X3.4 IBM/Microsoft DBCS ISO 8859-1 ISO 10646 (UCS-2) ISO 10646 (UCS-4) JIS C 6226</p><p>If this product is a communication gateway, describe the types of non-BACnet equipment/networks(s) that the gate- way supports: ______</p>
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages11 Page
-
File Size-