Substation Transformer Request Form

Substation Transformer Request Form

<p>R A T Cooper Power™ Series Substation Transformer Request Form. I C * Indicates Mandatory Fields - A Quotation cannot be provided without this information. ON GM *Customer Name/SAP Partner Number: * End User: End User Proposal No.: SM E R *Customer Location: City State * End User Location: City State C I * Job Name: * Job Location: City State A L * Sales Person: Company: *Your Due Date : </p><p>* Base kVA: * Number of Units: Fluid: Oil (Alt) * Frequency: 60Hz 50Hz * Phase: 3Ø 1Ø * Cooling: K(O)NAN * Temp Rise: 55° 55°/65° * Impedance: ANSI Std. </p><p>K(O)NAN/K(O)NAF 750kVA & Up 65° 75° PEAK 65°/75º PEAK Other K(O)NAN/Fut. K(O)NAF 750kVA & Up 55°75º PEAK (PEAK requires FR3) Taps: Split @2.5% Steps All 4 Below @2.5% Steps Other: </p><p>P * Voltage: Delta Wye BIL HV Winding Material: Aluminum (Standard) Copper R HV Sidewall Mounted Type: Spade Holes Eyebolt Condenser Style I *Segment: Please Choose M Bushings: Cover Mounted Dead Front: Wells only Wells w/ inserts Dead-break A Front R * HV Termination: None Partial Ht. ATC Full Ht. ATC Cable Entry: Top Bott. Flange Throat (for conn. to bus duct) Y * HV Arrester: UltraSIL Polymer Rating Please Choose Class Please Choose </p><p>S * Voltage: Delta Wye BIL LV Winding Material: Aluminum (Standard) Copper E C LV Sidewall Mounted Type: Spade Holes Eyebolt Condenser Style O *Segment: Please Choose Bushings: Cover Mounted Dead Front: Wells only Wells w/ inserts Dead-break N Front D * LV Termination: None Partial Ht. ATC Full Ht. ATC Cable Entry: Top Bott. Flange Throat (for conn. to bus duct) A R * LV Arrester: UltraSIL Polymer Rating Please Choose Class Please Choose Y ◙ Liquid Level gauge Contacts Must Supply complete Description of Under Oil 2 position Load-break Switch CT s’. ◙ Liquid Temp gauge Contacts VFI (Vacuum Fault Interrupter) Please Choose HV CT: Qty/Phase O P Ratio Acc Class C T ◙ Pressure/Vacuum gauge Contacts LV CT: Qty/Phase I Ratio Acc Class C O Cover mount PRD Contacts Paint: ANSI 61 Light Gray ANSI 70 Sky Gray N Neutral CT: Rapid-Rise Relay w/seal-in panel Other: A Ratio Acc Class C L ◙ Drain Valve Winding Temp. Ind. (one in middle phase) Listings: UL Listed UL Combination Add. CTs: See Spec page A C Control Box: NEMA 4 NEMA 4X Listed/Classified FM Approved C Conduit Type: SO Cable ALL PER APPLICABLE E * Location: Outdoors Indoors S Liquid Tight Flexible Indoors w/ Containment Pan ANSI STANDARDS ONLY S RGS >30” & Flex Metallic <30” O Area Classification: ◙ Non-Hazardous R Accessories Not Listed I E Site Considerations Ambient: 30 C Avg, 40 C Max Other: Seismic Zone 4: Yes S Elevation: <3300 ft (standard) Other: Remarks Envirotemp™ and FR3™ are licensed trademarks of Cargill, Incorporated.</p><p>Form# MKT-03-0105-F6D Rev 7</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us