Essentials of Fire Fighting (4Th Edition-FF1)-Chapter 9 Statements

Essentials of Fire Fighting (4Th Edition-FF1)-Chapter 9 Statements

<p> Essentials of Firefighting (4th Edition) Chapter 9-Ground Ladders FF 1 Test Review (Statements)</p><p>. NFPA 1931 provides specifications for ground ladders. . The bottom section of an extension ladder is called the bed. . The side rail of a ladder is called the beam. . Ladder locks on an extension ladder are called pawls. Also known as dogs or locks. . Toggles are found on pole ladders and are used to connect staypoles to the ladder. . Combination ladders are also called A-frame ladders. . Ladder stops can be found on extension ladders to keep sections from overextension. . Safety solvents should be used to remove tar, oil, and greasy residues from ladders. . Pompier ladders are used for climbing floor to floor via exterior windows. . Halyards are used to raise and lower sections of extension ladders. . Single ladders are also called wall ladders. . A soft-bristle brush and water is the most effective for cleaning ground ladders. . Roof ladders range in length from 12 to 24 feet. . The most common length for a folding ladder is 10 feet. . Extension ladders range from 12 to 39 feet. Ladders 40 feet or more are termed Pole ladders. . Roof ladders are designed to lie flat on a roof surface to provide footing for firefighters. . Single ladders can be used for quick access to windows and roofs of 1 to 2 story buildings. . NFPA 1931 requires that all folding ladders be equipped with footpads on the butt of the ladder. . Heat sensor labels, found on the inside of each section's beams, should be checked for color change when inspecting ground ladders. . Metal and fiberglass ladders are generally designed to be used with the "fly out", while wood ladders generally require the "fly in". . Pole ladders, ladders 40 feet or more, are also called Bangor ladders. . Combination ladders are required to have positive locking devices to hold the ladder in the open position. . Combination ladders can be used as a single ladder, an extension ladder, or an A-frame ladder. . Another name for pompier ladder is scaling ladder. . Ladder "maintenance" is "keeping the ladder in a state of usefulness or readiness". . Firefighters should be able to perform routine maintenance of ground ladders. . NFPA 1932 states that ladders should be kept free of moisture, not stored where they are exposed to engine exhaust or heat, and stored out of the elements. . Bubbled varnish on a wood ladder indicates exposure to heat. . Discoloration of fiberglass ladders can be an indicator of heat exposure. . Dark streaks in wood ladders indicates deterioration of the wood. . Fly sections and ladder pawl assemblies of extension ladder should move freely. . NFPA requires staypoles be attached to extension ladders 40 feet or longer. . Extension ladders can have a maximum length as much as 6 inches less than the designated length. . The maximum reach of a 50 foot extension ladder is 48 feet. . Extension ladders are most commonly carried by 2 firefighters using the low-shoulder carry. . The 3 firefighter flat-shoulder carry is most commonly used on extension ladders 35 feet or more. . The firefighter at the butt of a ladder determines the spot for the butt to be placed. . When positioned for ventilation, ladders should be placed in front of the window with the tip above the window opening. . Ground ladders should be kept a minimum of 10 feet away from energized electrical sources. . At least 4 firefighters are needed to bring a victim down a ladder. . Ground ladders should be cleaned after each use. . The forward end of a ladder should be carried slightly lowered. . Roof ladders should placed by carrying it up another ladder with the hooks forward and using the low-shoulder method. . The average distance from floor to floor in a residential building is 8 to 10 feet, while commercial buildings are 12 feet. . For a window rescue, the ladder tip should be placed just below the window sill. . Ladders should extend 5 rungs above the roof edge. . The reach of a 35 foot ladder is about 1 foot less than the ladder's extended length. . Fire department pumpers are required to carry 1 extension ladder of 24 feet or longer, 1 roof ladder of 14 feet or longer, and 1 folding ladder of 10 feet or longer. . The firefighter at the rear gives commands when lifting a ladder. . The optimum climbing angle for ground ladders is approximately 75 degrees. . Roof ladder hooks should be opened before ascending the climbing ladder unless 1 firefighter is carrying the ladder to the climbing ladder. . When using a ladder to project a hose stream into a window, the ladder should be placed in front of the window with the tip on the wall above the window. . When using a ladder to ventilate from, it should be placed to the windward side of the window with the tip even with the top of the window. . Firefighters should face the butt when carrying ladders (except roof ladders-face tip). . The proper distance from a building for heel placement of a ladder can be determined by dividing the ladders "used" length by 4. . Pole ladder should be placed flat on the ground prior to raising them. . A ladder belt is considered a Class I safety harness. . Ladders should be pivoted for repositioning prior to extending it. . Firefighters heeling ladders should wear head and eye protection. . A rope hose tool can be used to "tie in" and secure a ladder. . Wet wood, wet fiberglass, and metal ground ladders present an electrocution hazard when raised near electrical wires or equipment. . Correct climbing technique includes: eyes forward, arms straight, and body away from ladder.</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us