<p> working in partnership to promote quality regulation</p><p>Authorised Person: Job Reference Number: Date of Verification:</p><p>Make Location of Verification: </p><p>Model</p><p>Type</p><p>Class Type Approval Certificate (TAC) No Peripherals etc Test Certificate (TC) No(s)</p><p>Serial No(s) Complies with TAC? Yes No </p><p>Measures of length | Test Form | Version 3 | 1/4 working in partnership to promote quality regulation</p><p>Inspection Requirements Result Criteria 1. Intelligible Pass Fail 2. Sufficiently detailed to ensure: metrological characteristics defined Pass Fail the reproducibility of metrological performances of the MML the integrity of the instrument 3. Includes insofar as is relevant: a general description of the unit Technical manufacturing drawings Documentation: manufacturing procedures to ensure consistent production descriptions and explanations necessary for understanding the above Pass Fail a list of the standards and /or normative documents the MML is required to conform to descriptions of the solutions adopted to meet the essential requirements where standards/or normative documents have not been applied results of design calculations, examinations etc 4. Specifies details of markings applied Pass Fail Declaration of Conformity Available and identifiable to each model of MML submitted Pass Fail (issued by manufacturer) Certificate of conformity Issued for each batch (lot) of MML examined, tested and Pass Fail (issued by approved notified body) 50, 30, 20, 10, 5, 3, 2, 1.5, 1, 0.5 metre Permitted 1 decimetre Pass Fail nominal lengths 1 centimetre Abbreviations metre m, decimetre dm, centimetre cm, millimetre mm Pass Fail Maximum See schedule 1, paragraph 14 to SI 2006/1267 Permitted Pass Fail Errors MPEs may be marked on the appropriate test comparator The MML shall maintain an adequate stability of its metrological Durability characteristics over the period of time estimated by the Pass Fail manufacturer.</p><p>Measures of length | Test Form | Version 3 | 2/4 working in partnership to promote quality regulation</p><p> The MML to be designed so that any defect has minimal effect on Reliability Pass Fail its accuracy or so that such a defect is obvious. A MML shall have no feature likely to facilitate fraudulent use The possibility for misuse should be minimal A MML should be suitable for its intended use and straightforward Suitability Pass Fail to use. A MML shall be robust and its materials of construction suitable to allow it to remain within MPE when in use. Manufacturer’s mark or name Information to Information in respect of it’s accuracy (e.g. class ll) be borne by the Pass Fail Nominal value and unit of measurement (e.g. 1cm) measure Identification mark where appropriate Reference temperature 20°C unless otherwise specified and Reference marked on the MML Pass Fail conditions Tapes of 5m or more shall meet MPE when subjected to 50 N or other force specified/marked Such that length variations due to temperature changes up to +/- 8 C do not exceed MPE Materials Pass Fail MMLs made from materials which are likely to be affected by changes in humidity may only be class II or class III Nominal length The nominal length (e.g.1m) Pass Fail marking Symbol “CE” as laid down in paragraph 1.B (d) of Annex to CE Marking Decision 93/465/EEC. Pass Fail CE mark 5mm high minimum Capital letter “M” and the last two digits of the year of its affixing, M Mark and surrounded by a rectangle. Pass Fail year mark Height of the rectangle the same as the CE mark. M marking immediately follow CE marking Notified Body Notified body number follows the “CE” and the “M” marking Pass Fail Mark Location of The markings shall be clearly visible or easily accessible Pass Fail markings Shall be clear, non-erasable, unambiguous and non-transferable Indelibility of CE and M markings indelible Pass Fail marking Notified body number indelible or self-destructive upon removal </p><p>STATISTICAL TEST RESULTS FORM</p><p>Measures of length | Test Form | Version 3 | 3/4 working in partnership to promote quality regulation</p><p>Use one form for each group of measures, referred to in the directive as a “homogenous lot”, which can be considered as being the same for the purposes of statistical sampling, i.e., manufactured by the same production process, and belong to the same precision class. (NB. maximum lot size is 10,000) Product Batch No. Declaration of Nominal Type (e.g. Material Number Code Conformity Length (m) tape, folding, Submitted Reference single / double number sided)</p><p>Total number of measures submitted for approval (Lot size) =</p><p>1st sample size 2nd sample size</p><p>1st sample number Incorrect 2nd sample number Incorrect</p><p>Comparator ID</p><p>Pass Fail Verification marks applied Yes No Serial no. of certificate of conformity / non-conformity where applicable If fail, ‘Rights of Appeal’ notice issued? Yes No </p><p> dd / mm / yyyy</p><p>Authorised verification officer Date</p><p> dd / mm / yyyy</p><p>Reviewing Officer Date</p><p>Measures of length | Test Form | Version 3 | 4/4</p>
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages4 Page
-
File Size-