HOW to : VLT Automation Drive FC302

HOW to : VLT Automation Drive FC302

<p> HOW TO : VLT Automation Drive FC302</p><p>Example of Constant Pressure Pump Control</p><p>In a pumping system a constant pressure of 5 Bar is to be maintained using the integrated PID controller in the FC302 HVAC. Normal regulation is required, i.e. the pump speed will reduce when the pressure increases beyond the set-point and vice-versa. The pressure transmitter used is ranged 0-10 bar and gives a feedback signal of 4-20mA. An internal set point is to be used. Set switch S202 to ‘on’ = Current (0-20mA) Once set, Power unit off and back on again to accept new switch settings. These switches are located underneath the Keypad. This then uses terminals 54 and 55 for the feedback signal. </p><p>The following settings of parameters are required: 1. Activate the PID controller by setting Parameter 1.00 to ‘PROCESS’ 2. Set the speed limits 4.12 low limit 4.14 high limit if working in Hz. Or 4.11 low limit 4.13 high limit if working in RPM. As defined in parameter 0.02 3. Set Parameter 7.20, Process CL Feedback 1 to ‘Analog input 54’ which defines the input on terminal 54, to be the PID feedback. 4. Change Parameter 6.22 to 4 mA and leave 6.23, which scales the input on terminal 54, at the setting of 20 mA. 5. Set parameter 3.00 to Min-Max ( 0 to +ve feedback values) 6. Set Parameter 3.01 to the Units of the transmitter scaling, in this example ‘Bar’ 7. Set Parameter 3.02 to the minimum feedback of the transmitter, in this example the factory setting of ‘0’. Also set 6.24 to this minimum value 8. Set Parameter 3.03 to the maximum feedback of the transmitter, in this example ‘10’. Also set 6.25 to this maximum value 9. Programme in your set point in % of process units in Parameter 3.10 (0), ‘Preset reference’, in this example ‘50%’. 10. Set Parameter 7.33, ‘Proportional Gain’, to ‘0.5’. This may then need adjustment to stabilise conditions (Refer to FC302 Design Guide). 11. Set Parameter 7.34, ‘Integration Time’, to ‘10’. This may then need adjustment to stabilise conditions (Refer to FC302 Design Guide). Setting of the following Parameters may also be helpful (See FC302 Design Guide for description): 1. Parameter 7.32, ‘PID Start Speed’. 2. Parameter 7.38, ‘Process PID Feed Forward Factor’. </p><p>All the above settings are in addition to the basic set-up of the unit that can normally be carried out using the Quick Menu. During set-up of the PID Controller it can be useful to indicate several data values in the display at the same time, e.g. ‘Set point’, ‘Feedback’, ‘Frequency’, ‘Current’, by using both the large and small display readouts. These are displayed by using the STATUS key and are configured using Parameters 0.20 – 0.24 The parameter displayed in the centre of the keypad can also be selected to suit the application e.g. Bar – flow rates etc. in parameter 0-23 </p><p>NB. The minimum requirement to operate the FC302 in remote control is to have both terminals 18 and 27 ‘ON’ to enable the unit. This is usually carried out by connecting 24 Volts DC from terminal 12. Terminal 37 (safe stop) must always be connected to T12 (24volts)</p><p>FC302 PID Page 1 of 1</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us