Sign Placement for Advanced Sign with Flasher

Sign Placement for Advanced Sign with Flasher

<p>1. </p><p>1. SIGNS AS DETERMINED BY MoDOT PERSONNEL AS PER EPG 903 HIGHWAY SIGNING. ADDITIONAL SIGNING MAY BE REQUIRED. </p><p>DRIVEWAY, CROSSWALK OR CONDITION APPLICABLE TO ADVANCED SIGN </p><p> d NOTE: LENGTH "d" DETERMINED </p><p>BY MoDOT PERSONNEL AS PER EPG 903 HIGHWAY SIGNING. REFERENCE EPG 903.6 WARNING SIGNS AND EPG 903.19 SIGNING FOR SCHOOL AREAS. </p><p>. 1. </p><p>SIGN PLACEMENT FOR ADVANCED SIGN WITH FLASHER FIGURE 902.11, PAGE 1 TOP OF POST MOUNT 12 INCH 17 FEET MAXIMUM HEIGHT SIGNAL INDICATION WITH 5 INCH FROM THE ELEVATION AT BACK PLATE AND TUNNEL VISOR THE EDGE OF SHOULDER OR TOP OF CURB</p><p>12 INCHES URBAN - MINIMUM 2 FEET FROM FACE OF CURB OR MINIMUM 6 FEET FROM EDGE OF SHOULDER</p><p>WARNING OR SPEED LIMIT SIGN (BANDED TO POST)</p><p>CONTROL ENCLOSURE IF MOUNTED ON POST (BACK OF POST)</p><p>SUPPLEMENTAL SIGN (IF REQUIRED)</p><p>7 FEET MINIMUM 6 FEET MINIMUM</p><p>MEASURED FROM THE MEASURED FROM THE ELEVATION AT THE EDGE ELEVATION AT THE EDGE OF SHOULDER OR TOP OF SHOULDER OR TOP OF CURB OF CURB</p><p>4 1/2 INCH PEDESTAL POST AND BASE. LENGTH OF POST AS NEEDED TO MEET SPECIFIED DIMENSIONS</p><p>TYPE C CONCRETE BASE</p><p>2" MIMIMUM RIGID CONDUIT AND WIRING</p><p>ADVANCED FLASHER WITH WARNING SIGN OR SPEED LIMIT FIGURE 902.11, PAGE 2 W6X9 OR W6X15 POST, GALVANIZED</p><p>METER SOCKET (IF REQUIRED)</p><p>CONTROL ENCLOSURE</p><p>SERVICE DISCONNECT BOX (REQUIRED)</p><p>CONDUIT HUBS, THREADED WITH SEALING WASHERS</p><p>3 FEET MINIMUM 3' - 5'6"</p><p>GROUND LINE</p><p>GROUND ROD, 3/4" X 10' MINIMUM ELECTRICALLY BONDED TO CONTROL 3 FOOT MINIMUM ENCLOSURE AND DISCONNECT WITH #6 AWG BARE COPPER WIRE</p><p>CONDUIT AND CABLE* FROM POWER SOURCE AND/OR ACTIVATION CONDUIT/CABLE BUTTON TO FLASHER</p><p>CONDUIT/CABLE TO FLASHER</p><p>CONCRETE BASE</p><p>18" DIAMETER</p><p>* IF POWER SOURCE IS THE UTILITY COMPANY, MINIMUM 2" RIGID STEEL CONDUIT CONTROL PEDESTAL FOR ADVANCED FLASHER FIGURE 902.11, PAGE 3 TO NEMA FLASHERS FLASHER</p><p>AC + BREAKER</p><p>NEUTRAL</p><p>AC NEUTRAL</p><p>ALL WIRING SHALL BE #12 AWG MINIMUM BREAKER - 15 AMP</p><p>WIRING DIAGRAM FOR FLASHER - CONSTANT OPERATION FIGURE 902.11, PAGE 4 TO NEMA FLASHERS FLASHER</p><p>AC + BREAKER</p><p>120 VAC RELAY TIME DELAY RELAY</p><p>TO ACTIVATION BUTTON (NORMALLY OPEN MOMENTARY CONNECTION)</p><p>NEUTRAL</p><p>AC NEUTRAL</p><p>RELAYS - 8 PIN OCTAL BASE WITH MINIMUM 5 AMP CONTACTS TIME DELAY RELAY - SSAC INC. TUD 120VAC OR EQUIVALENT ALL WIRING SHALL BE #12 AWG MINIMUM BREAKER - 15 AMP</p><p>WIRING DIAGRAM FOR ADVANCED FLASHER - REMOTE ACTIVATION FIGURE 902.11, PAGE 5 TIME TO NEMA FLASHERS CLOCK FLASHER</p><p>AC + BREAKER 120 VAC RELAY TIME DELAY RELAY</p><p>SPECIAL EVENT BUTTON (NORMALLY OPEN MOMENTARY SWITCH)*</p><p>NEUTRAL</p><p>AC NEUTRAL</p><p>RELAYS - 8 PIN OCTAL BASE WITH MINIMUM 5 AMP CONTACTS TIME DELAY RELAY - SSAC INC. TUD 120VAC OR EQUIVALENT ALL WIRING SHALL BE #12 AWG MINIMUM BREAKER - 15 AMP TIME CLOCK SHALL CONFORM TO APPLICABLE STANDARD SPECIFICATIONS AND THE AP- PROVED PRODUCTS LIST * SPECIAL EVENT BUTTON SHAL BE MOUNTED 3' TO 5'6" ABOVE GROUND. THIS MAY REQUIRE A SEPARATE ENCLOSURE </p><p>WIRING DIAGRAM FOR ADVANCED FLASHER - TIME CLOCK ACTIVATION FIGURE 902.11, PAGE 6 TO NEMA FLASHERS FLASHER</p><p>AC + LOOP DETECTOR BREAKER</p><p>120 VAC RELAY TIME DELAY RELAY</p><p>LOOP</p><p>SHELF MOUNT DETECTOR</p><p>AC IN RELAY</p><p>NEUTRAL</p><p>AC NEUTRAL</p><p>RELAYS - 8 PIN OCTAL BASE WITH MINIMUM 5 AMP CONTACTS TIME DELAY RELAY - SSAC INC. TUD 120VAC OR EQUIVALENT ALL WIRING SHALL BE #12 AWG MINIMUM (EXCEPT DETECTOR WIRING) BREAKER - 15 AMP SEE PROJECT DEVELOPMENT MANUAL, STANDARD SPECS. AND STANDARD PLANS FOR LOOP DETECTOR DESIGN DETECTOR SHALL CONFORM TO APPLICABLE STANDARD SPECIFICATIONS AND THE AP- PROVED PRODUCTS LIST</p><p>WIRING DIAGRAM FOR ADVANCED FLASHER - DETECTOR ACTIVATION FIGURE 902.11, PAGE 7 AC NEUTRAL</p><p>110 VAC RELAY THROUGH PHASE GREEN OUTPUT FOR APPROACH A (110 VAC) AC NEUTRAL</p><p>TO APPROACH A FLASHER AC NEUTRAL NEMA FLASHER TO APPROACH B AC+ FROM FLASHER SIGNAL BUSS POWER*</p><p>AC NEUTRAL THROUGH PHASE GREEN OUTPUT FOR APPROACH B (110 VAC) 110 VAC RELAY AC NEUTRAL</p><p>ALL EQUIPMENT INSTALLED IN SIGNAL CONTROLLER CABINET RELAYS - 8 PIN OCTAL BASE WITH MINIMUM 5 AMP CONTACTS ALL WIRING SHALL BE #12 AWG MINIMUM NEMA FLASHER SHALL BE SEPARATE FROM NEMA FLASHER USED FOR SIGNAL FLASH * FLASHERS SHALL ONLY OPERATE WHEN SIGNALS ARE OPERATING (NOT FLASHING). IF PROGRAM FLASH (LOAD SWITCH FLASH) IS USED, DIFFERENT CIRCUITRY WILL NEED TO BE DESIGNED.</p><p>WIRING DIAGRAM FOR ADVANCED FLASHER - SIGNAL PHASE ACTIVATION FIGURE 902.11, PAGE 8 AC NEUTRAL</p><p>TO APPROACH A FLASHER AC NEUTRAL NEMA</p><p>FLASHER AC+ FROM TO APPROACH B FLASHER SIGNAL BUSS POWER*</p><p>AC NEUTRAL</p><p>ALL EQUIPMENT INSTALLED IN SIGNAL CONTROLLER CABINET ALL WIRING SHALL BE #12 AWG MINIMUM NEMA FLASHER SHALL BE SEPARATE FROM NEMA FLASHER USED FOR SIGNAL FLASH * FLASHERS SHALL ONLY OPERATE WHEN SIGNALS ARE OPERATING (NOT FLASHING). IF PROGRAM FLASH (LOAD SWITCH FLASH) IS USED, DIFFERENT CIRCUITRY WILL NEED TO BE DESIGNED.</p><p>WIRING DIAGRAM FOR ADVANCED FLASHER - SIGNALS ON ACTIVATION FIGURE 902.11, PAGE 9</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    9 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us