Openplant Powerpid SS4 External File Modifications

Openplant Powerpid SS4 External File Modifications

<p>OpenPlant PowerPID SS4 External File Modifications</p><p>Schemas</p><p>OpenPlant.01.02  Added Classes</p><p>ANALOGUE_SIGNAL_INPUT_CIRCUIT_BOARD,ANALOGUE_SIGNAL_OUTPUT_CIRCUIT_BOARD, ANALOGUE_TO_DIGITAL_CONVERTER, AIR_DISTRIBUTOR, AIR_FILTER, AIR_HANDLING_UNIT, AIR_HANDLING_UNIT_FIVE_ENDS, AIR_HANDLING_UNIT_FOUR_ENDS, AIR_HANDLING_UNIT_THREE_ENDS, AIR_HANDLING_UNIT_TWO_ENDS, ALARM, ALARM_SIGNAL_PROCESSING_CIRCUIT_BOARD, AMPLIFIER, AMPLIFIER_CIRCUIT_BOARD, ANTISURGE_CONTROLLER, AUDIBLE_ALARM, BOURDON_TUBE, BOLT_COUPLING, BRICK_TERMINAL, CAPACITIVE_PRESSURE_ELEMENT, CPU_SOCKET, CURRENT_TO_CURRENT_CONVERTER, CURRENT_TO_PRESSURE_CONVERTER, CURRENT_TO_VOLTAGE_CONVERTER, CYCLOCONVERTER, SPLICE, SPUR, CABLETRAY_COMPONENT, CAM_AND_GROOVE_COUPLING, CARD_PORT, CHARGE_CONTROLLER, CONTROL_CIRCUIT_BOARD, DC_POWER_SUPPLY, DIGITAL_INPUT_CIRCUIT_BOARD, DIGITAL_OUTPUT_CIRCUIT_BOARD, DIGITAL_TO_ANALOGUE_CONVERTER, DIRECT_AC_CONVERTER, DIRECT_DC_CONVERTER, DOUBLE_CONVERTER, DAMPER, DISTRIBUTION_BOARD, DOUBLE_ACTING_PNEUMATIC_DIAPHRAGM_ACTUATOR, DRESSER_COUPLING, DUAL_INLET_VARIABLE_AIR_VOLUME_DEVICE, DUCT_TRANSITION, ELECTRIC_* FOUR_HY_QUADRANT_CONVERTER, FREQUENCY_TO_*, FAN_POWER_UNIT, FIELDBUS_INPUT_OUTPUT, FIELDBUS_NETWORK_SEGMENT, FIRE_DAMPER, FIRE_DAMPER_BLADE, FLEXIBLE_CONNECTOR, FLEXIBLE_COUPLING, FLOW_CONTROLLER, FLUID_MIXER, GLAND, GOOSENECK, HUMIDIFIER, HVAC_*, HYDRAULIC_CONTROLLER, INDIRECT_AC_CONVERTER, INDIRECT_DC_CONVERTER, INPUT__HY__OUTPUT_CIRCUIT_BOARD, INPUT_CIRCUIT_BOARD, IN_HY_LINE_MIXER, INTERNAL_POWER_SUPPLY, LANDING_STRIP, LEVEL_CONTROLLER, LIQUID_MIXER, MECHANICAL_CONTROLLER, MECHANICAL_JOINT_GASKET, MEGA_LUG, METALLIC_GASKET, MULTIPLEXOR_TERMINAL_STRIP, NON_WETTED_TRANSDUCER, NODE, ONE_HY_QUADRANT_CONVERTER, OUTPUT_CIRCUIT_BOARD, OVAL_GAS_PORT, OVAL_SUPPLY_DIFFUSER, PHASE_CONVERTER, PHASE_SHIFTER, PHOTODIODE, PHOTOELECTRIC_TRANSDUCER, PHOTOELETRIC_TRANSDUCER, POSITION_TRANSDUCER, PRESSURE_ELEMENT, PRESSURE_TO_CURRENT_CONVERTER, PRESSURE_ELEMENT_3051CG5A22A1KB4I1L4M6Q4, PRESSURE_TO_VOLTAGE_CONVERTER, PIPE_TEE_BASE_TYPE, PIPE_TEE_REDUCING_BOTH_RUNS, PIPELINE_END_SEAL, POWER_SUPPLY, PRESSURE_CONTROLLER, PUSH_ON_JOINT_GASKET, PUSH_ON_RESTRAINT_JOINT_GASKET, RECTIFIER, RESISTANCE_TO_CURRENT_CONVERTER, REVERSIBLE_CONVERTER, RECORDING_CONTROLLER, RECTANGULAR_GAS_PORT, RECTANGULAR_GOOSENECK, RECTANGULAR_SUPPLY_DIFFUSER, RESTRAINT_GLAND, ROOF_CURB, ROUND_DIFFUSER, ROUND_SUPPLY_DIFFUSER, SEMICONDUCTOR_CONVERTER, SIGNAL_CONVERTER, SINGLE_CONVERTER, SHUT_OFF_DAMPER, SIGNAL_CONNECTOR_SYMBOL, SINGLE_INLET_VARIABLE_AIR_VOLUME_DEVICE, SPLIT_GLAND, START_CONTROLLER, STATIC_MIXER, STEAM_HUMIDIFIER, SUPPLY_GRILLE_DIFFUSER, SWITCHGEAR_AND_CONTROLGEAR, THERMOCOUPLE, THERMOELECTRIC_TRANSDUCER, THYRISTOR_UNIT, TRANSDUCER, TWO_HY_QUADRANT_CONVERTER, TYPE_*_THERMOCOUPLE, TEMPERATURE_CONTROLLER, ULTRASONIC_TRANSDUCER, VARIABLE_SPEED_DRIVE_CONVERTER, VOLTAGE_TO_CURRENT_CONVERTER, VOLTAGE_TO_PRESSURE_CONVERTER, VOLTAGE_TO_VOLTAGE_CONVERTER, VARIABLE_AIR_VOLUME_DEVICE, WETTED_TRANSDUCER</p><p> Added Relationships</p><p>DEVICE_HAS_NODE, DOCUMENT_HAS_BORDER, DOCUMENT_HAS_HVAC_NETWORK_SYSTEM, EQUIPMENT_HAS_MANWAY, HVACSYSTEM_HAS_SEGMENT, </p><p>OBJECT_HAS_LABEL, PLANT_HAS_NAMED_ITEM, SEGMENT_CONNECTS_TO_PROCESS_CONNECTOR, SEGMENT_CONNECTS_TO_NODE, </p><p>SEGMENT_HAS_HVAC_COMPONENT, SIGNALLINE_CONNECTS_TO_SIGNAL_CONNECTOR</p><p> Modified Classes</p><p> o ANNOTATION_ITEM</p><p>. Added Properties: TEXT_EXPRESSION, TEXT_STRING</p><p> o CABLE</p><p>. Added Properties: ALTERNATIVE_NAME, COMMENT, INTRINSICALLY_SAFE_INSTALLATION, LOCATION, PROJECT_STATUS, REVISION_NUMBER</p><p> o CABLE_CORE</p><p>. Added Properties:REVISION_NUMBER, WIRE_NUMBER</p><p> o DOCUMENT</p><p>. Added Properties:REVISION_NUMBER, STATUS</p><p> o FAN</p><p>. Added Properties: CELL_LIBRARY , CELL_SYMBOL, CONNECTION_TYPE, LENGTH, MAIN_DIAMETER, MAIN_HEIGHT, MAIN_WIDTH</p><p> o FASTENER</p><p>. Removed RANGE o GAS_PORT</p><p>. Added Properties: END_PREPARATION_LENGTH, END_PREPARATION_SIZE o GASKET</p><p>. Added Properties: DIAMETER, THICKNESS o GEARBOX_OPERATOR</p><p>. Added Properties: GEAR_BOX_*, HANDLE_*, TOTAL_HEIGHT o HVAC_COMPONENT</p><p>. Multiple adds and removes, Use Class Editor Compare to see differences o HVAC_DUCT</p><p>. Added Properties: END_TYPE, MAIN_CONNECTION_LENGTH, RUN_CONNECTION_LENGTH o HVAC_RECTANGULAR_DUCT</p><p>. Removed NOMINAL_HEIGHT, NOMINAL_WIDTH o HVAC_ROUND_DUCT</p><p>. Removed NOMINAL_DIAMETER o INTERFACE_CARD</p><p>. Added Properties: BACKPLANE_ADDRESS, CABINET_ID, CARD_RACK_ID,CONTROLLER_ID,NETWORK_MODULE,NETWORK_NODE_NUMBER, NODE_DESCRIPTION,REDUNDANCY_REQUIREMENTS,SIDE_MOUNTED,SUB_SLOT_ID,OU TPUT_DIRECTION,IO_TYPE,LOCATION,PROJECT_STATUS,REVISION_NUMBER o IO_CHANNEL</p><p>. O_CHANNEL_ADDRESS, IO_CHANNEL_PRIORITY, IO_GROUPING, IO_TYPE, REVISION_NUMBER</p><p> o NAMED_ITEM</p><p>. Added Properties: UNIT, PLANT_AREA o INSTRUMENT</p><p>. Added Properties: GUID, ALARM_RANGE, ALARM_SET_POINT, ALARM_TYPE, ALTERNATIVE_NAME, FIELD_CONTACT, INPUT_DESCRIPTION_CLOSED, INPUT_DESCRIPTION_OPEN, INPUT_NORMAL_STATE, IO_TYPE, LOWER_LIMIT_OUTPUT_PULSE_DURATION, LOWER_LIMIT_OUTPUT_SIGNAL, MEMORY_ADDRESS, PROJECT_STATUS, REQUISITION_NUMBER, REVISION_NUMBER, SEGMENT_ADDRESS, COMMENT, OUTPUT_DIRECTION, OUTPUT_MINIMUM_PULSE_DURATION, UPPER_LIMIT_OUTPUT_SIGNAL, INPUT_LIMIT_H, OUTPUT_LIMIT_H, DATA_TYPE, COLOUR_CODE, IO_CHANNEL_ADDRESS DCS_KEYWORD, DCS_TAG_IDENTIFICATION_CODE, DCS_TAG_DESCRIPTION, COST, DIRECTION, WEIGHT, OPERATING_VOLTAGE o LOOP o Added Property : ALTERNATIVE_NAME, PROJECT_STATUS, REVISION_NUMBER, SEGMENT_ADDRESS o Removed GUID o MOTOR o Added Property: ENCLOSURE_CLASSIFICATION, REVISION_NUMBER o MOTOR_CONTROL_CABINET o Added Property: PROJECT_STATUS, REVISION_NUMBER, SUBSTATION_ID o Removed GUID o MULTIPLEXOR o Multiple adds and removes, Use Class Editor Compare to see differences o PIPING_COMPONENT o Multiple adds and removes, Use Class Editor Compare to see differences o PANEL o Multiple adds and removes, Use Class Editor Compare to see differences o PIPE_COUPLING</p><p> o WALL_THICKNESS o PIPE_ELBOW_BASE_TYPE</p><p> o Multiple adds and removes, Use Class Editor Compare to see differences o PIPING_NETWORK_SEGMENT</p><p> o Added Property SCHEDULE, TAG_NUMBER o PIPING_NETWORK_SYSTEM</p><p> o Added Property SERVICE, TAG_NUMBER o PLATE_AND_FRAME_HEAT_EXCHANGER</p><p> o Added Property HEAT_EXCHANGER_SHELL_MASS_FLOW_RATE, HEAT_EXCHANGER_TUBE_MASS_FLOW_RATE o SHELL_AND_TUBE_HEAT_EXCHANGER o Added Property: SHELL_MASS_FLOW_RATE, TUBE_MASS_FLOW_RATE</p><p> o TERMINAL</p><p> o Multiple adds and removes, Use Class Editor Compare to see differences</p><p> o TERMINAL_STRIP</p><p> o Multiple adds and removes, Use Class Editor Compare to see differences</p><p> o TRAY</p><p> o Multiple adds and removes, Use Class Editor Compare to see differences</p><p> o WELD</p><p> o Removed ATTRIBUTES1</p><p> o WELD_VALUE_MAP</p><p> o Added Property: COMPRESSION_END, PUSH_ON_END, PUSH_ON_RESTRAINED_END</p><p> Removed Reference</p><p>. Unit_Attributes</p><p>OpenPlant_Supplemental_Tagging.01.01.ecschema.xml  Added Classes</p><p> o ANNOTATION_COMPONENTS</p><p> o HVAC_NETWORK_SEGMENT</p><p> o HVAC_NETWORK_SYSTEM</p><p> o SEGMENT_TERMINATION</p><p> Modified Classes</p><p> o LOOP</p><p>. Modified Property: NAME</p><p> o SERVICE</p><p>. Added :RequiresUniqueBusinessKey</p><p> o SUPPORT . Removed BusinessKeySpecification</p><p> Added Schema Custom Attribute</p><p> o Supplemental Schema MetaData</p><p>OpenPlant_PID.01.02  Added classes: </p><p> o BASE_EQUIPMENT_ANNOTATION, BASE_PIPE_LINE_ANNOTATION, BRICK_TERMINAL, CABLE_CORE, SPLICE, SPUR, CARD_PORT, CARD_TERMINAL_STRIP, DISTRIBUTED_CONTROL_SYSTEM, EDGE_MILL, ELECTRONIC_CIRCUIT_BOARD, EQUIPMENT_ANNOTATION_ALT1, EQUIPMENT_ANNOTATION_ALT2, EQUIPMENT_ANNOTATION_ALT3, FIELDBUS_NETWORK_SEGMENT, FIELDBUS_INPUT_OUTPUT, FLUID_STREAM, INSTRUMENT_LINE_LIST, INTERFACE_CARD, INTERNAL_DEVICE_PANEL_TERMINAL_STRIP, IO_CHANNEL, LANDING_STRIP, LOCK_LEVEL_LIST, MULTIPLEXOR, MULTIPLEXOR_TERMINAL_STRIP, PIPE_LINE_ANNOTATION_ALT6, PIPE_LINE_ANNOTATION_ALT7, PROCESS_SIMULATION_ITEM, PROCESS_SIMULATION_UNIT_OP, SEGMENT_TERMINATION, SIMULATION_ITEM, STREAM, TERMINAL, TRANSMITTER. SHELL_AND_TUBE_HEAT_EXCHANGER, INDIRECT_CONTACT_HEAT_EXCHANGER, TUBULAR_HEAT_EXCHANGER</p><p> Added relationship classes:</p><p> o EQUIPMENT_HAS_INSULATION, OBJECT_HAS_IDENTIFICATION_PARAMETRIC, PLANT_HAS_NAMED_ITEM, PLANT_HAS_NAMED_ITEM</p><p> Deleted class PIPING_ANNOTATION</p><p> Modified classes:</p><p> o PLANT_BASE_OBJECT </p><p>. Added Property: ELEMENT_ID </p><p> o CABLE </p><p>. changed order of base classes </p><p>. Added properties: ALTERNATIVE_NAME, COMMENT, INTRINSICALLY_SAFE_INSTALLATION, LOCATION, PROJECT_STATUS, REVISION_NUMBER</p><p> o CARD </p><p>. changed order of base classes </p><p>. Added properties: IO_TYPE, LOCATION, PROJECT_STATUS, REVISION_NUMBER</p><p> o CARD_PANEL, ELECTRICAL_PANEL, FIELD_PANEL, FIELDBUS_PANEL</p><p>. changed order of base classes</p><p> o EQUIPMENT . Added Properties: INSULATION, EQUIPMENT_INSULATION_THICKNESS o FLOW_ELEMENT_VOLUME_METER </p><p>. modified DisplayLabel o INSTRUMENT</p><p>. Moved custom attributes ExtendType and BMF_PROP_CUSTOM_ATTRIBUTES on DEVICE_TYPE_CODE property to supplemental schemas</p><p>. Added properties: ALARM_RANGE,ALARM_SET_POINT,ALARM_TYPE,ALTERNATIVE_NAME,COST,DATA_TYPE,D IRECTION,FIELD_CONTACT,INPUT_DESCRIPTION_CLOSED</p><p>INPUT_DESCRIPTION_OPEN,INPUT_NORMAL_STATE,IO_TYPE,LOWER_LIMIT_OUTPUT_PUL SE_DURATION,LOWER_LIMIT_OUTPUT_SIGNAL,MEMORY_ADDRESS</p><p>OPERATING_VOLTAGE,PROJECT_STATUS,REQUISITION_NUMBER,REVISION_NUMBER,SEG MENT_ADDRESS,UPPER_LIMIT_OUTPUT_SIGNAL,WEIGHT,OUTPUT_DIRECTION</p><p>OUTPUT_MINIMUM_PULSE_DURATION,COMMENT o MOTOR_CONTROL_CABINET</p><p>. changed order of base classes </p><p>. Added properties: PROJECT_STATUS, REVISION_NUMBER, SUBSTATION_ID o OFFPAGE_CONNECTOR o PIPING_NETWORK_SYSTEM</p><p>. Added properties INSULATION_THICKNESS, INSULATION</p><p>. Removed custom attribute BMF_NOTIFY_RELATED_COMPONENT_OF_PROPERTY_VALUE_CHANGE from NUMBER property o PANEL</p><p>. changed order of base classes </p><p>. Added properties: ALTERNATIVE_NAME, COLOUR_CODE, COMMENT, INTRINSICALLY_SAFE_INSTALLATION, PROJECT_STATUS, REVISION_NUMBER, SUPPLIER o PIPE_LINE_ANNOTATION</p><p>. Removed properties: NAME, PIPELINEANNOTATION, PIPELINE_NAME, SIZE, SPECIFICATION o PIPE_LINE_ANNOTATION_ALT1, PIPE_LINE_ANNOTATION_ALT2, PIPE_LINE_ANNOTATION_ALT3, PIPE_LINE_ANNOTATION_ALT4, PIPE_LINE_ANNOTATION_ALT5 changed base class o TERMINAL_STRIP . changed order of base classes </p><p>. Added properties: ELEVATION, HOUSING_MATERIAL, INTERNAL_SEGMENT_TERMINATOR, LEVEL_NAME, LIFECYCLE, MATERIAL, NAME, OPERATING_TEMPERATURE_RANGE, ORDER_NUMBER, PAINT_CODE, PROJECT_STATUS, REVISION_NUMBER, SCREW_TORQUE_RANGE, SEGMENT_TERMINATOR, STOCK_NUMBER, STORAGE_TEMPERATURE_RANGE, SUFFIX, TAG_NUMBER, TOTAL_WEIGHT, UNIT_NUMBER</p><p> o INSTRUMENT_HAS_OUTPUT changed DisplayLabel and Description to indicate this relationship has been deprecated. It is the equivalent of INSTRUMENT_HAS_INPUT (reversed).</p><p>OpenPlant_PID_Lists.01.02  Added entry to RELATIONSHIP_CLASS_MAPPING_LIST for oppid:SEGMENT_CONNECTS_TO_NODE between source oppid:PIPING_NETWORK_SEGMENT and target oppid:SEGMENT_TERMINATION</p><p> Added entry to RELATIONSHIP_CLASS_MAPPING_LIST for oppid:OBJECT_HAS_IDENTIFICATION_PARAMETRIC between source oppid:PLANT_BASE_OBJECT and target oppid:IDENTIFICATION_PARAMETRIC</p><p> Added class COPY_RELATIONSHIP_CLASS_MAPPING_LIST</p><p>Database mapping</p><p>PlantProjectSchema.01.02.ecschema.xml  Added DOCUMENT_HAS_SEGMENT_TERMINATION relationship class</p><p> Added DOCUMENT_HAS_PIPE_REDUCER relationship class</p><p> Modified INSTRUMENT_HAS_INSTRUMENT_INPUT relationship class</p><p> o Added role label to Target</p><p> Modified INSTRUMENT_HAS_INSTRUMENT_OUTPUT relationship class, changed displayLabel to indicate Deprecated</p><p> Added REDUCER_CONNECTS_TO_SEGMENT relationship class</p><p> Added SEGMENT_HAS_TIE_IN relationship class</p><p> Added OBJECT_HAS_SPECIALTY_ITEM relationship class</p><p>PlantProjectSchema.01.02_Autoplant_PIW.01.02.mapping.xml  Added SEGMENT_TERMINATION, PIPE_REDUCER, FIELD_STREAM, INTERNAL_DEVICE classes  Modified BRICK_TERMINAL, CABLE, CARD_PANEL, ELECTRICAL_PANEL, FIELD_PANEL, FIELDBUS_NETWORK_SEGMENT, FIELDBUS_PANEL, FOUNDATION_FIELDBUS_CARD, INSTRUMENT, INTERFACE_CARD, LANDING_STRIP, LOOP, MOTOR_CONTROL_CABINET, MULTIPLEXOR, MULTIPLEXOR_TERMINAL_STRIP, SPLICE, SPUR, TERMINAL_STRIP, TRUNK, classes</p><p> o renamed TAG_STATUS property to PROJECT_STATUS</p><p> modified CARD_PANEL, ELECTRICAL_PANEL, FIELD_PANEL, FIELDBUS_PANEL classes</p><p> o renamed COLOUR property to COLOUR_CODE</p><p> modified CHEMICAL_SEAL, CONTROL_VALVE, FLOW_ELEMENT, INSTRUMENT, MULTIPLEXOR classes</p><p> o renamed COMMENTS property to COMMENT</p><p> modified DOCUMENT, class</p><p> o renamed REVISION property to REVISION_NUMBER</p><p> modified INSTRUMENT class</p><p> o Changed all Inactive state properties to Active state.</p><p> o Renamed OUTPUT_SIGNAL_LOWER_LIMIT property to LOWER_LIMIT_OUTPUT_SIGNAL</p><p> o Renamed OUTPUT_SIGNAL_UPPER_LIMIT property to UPPER_LIMIT_OUTPUT_SIGNAL</p><p> modified LOOP, MOTOR class</p><p> o changed all Inactive state properties to Active state</p><p> Renamed MULTIPLEXER class to MULTIPLEXOR</p><p> o changed INPUT_LIMIT_H & INPUT_LIMIT_L property from Active state to Inactive state</p><p> o Renamed OUTPUT_SIGNAL_LOWER_LIMIT property to LOWER_LIMIT_OUTPUT_SIGNAL</p><p> o Renamed OUTPUT_SIGNAL_UPPER_LIMIT property to UPPER_LIMIT_OUTPUT_SIGNAL</p><p> Renamed MULTIPLEXOR_TERMINAL_STRIP class to MULTIPLXER_TERMINAL_STRIP</p><p> Modified PIPING_NETWORK_SEGMENT class</p><p> o changed TEST_PRESSURE property from Active state to Inactive state  Added SEGMENT_CONNECTS_TO_NODE, DOCUMENT_HAS_SEGMENT_TERMINATION, DOCUMENT_HAS_PIPE_REDUCER, REDUCER_CONNECTS_TO_SEGMENT, SEGMENT_HAS_TIE_IN, OBJECT_HAS_SPECIALTY_ITEM relationships</p><p> Modified INSTRUMENT_HAS_INSTRUMENT_INPUT relationship</p><p> o Renamed Table from INSTR to INSTRUMENTCONTROL</p><p> o Added contents to Instance entry</p><p> o Changed SourceKey’s Column name to INSTRUMENTCONTROL.KEYTAG_OUTPUT</p><p> o Changed TargetKey’s Column name to INSTRUMENTCONTROL.KEYTAG_INPUT</p><p> Modified PLANTPROJECT_DATABASEMAPPING Database</p><p> o Set connectionString=””</p><p> o Added DATACHANGE, INSTRUMENTCONTROL tables</p><p>PID Configuration File  Changed</p><p> o PID_LOG_LEVEL: changed to ERROR (-1) o BMF_SYSTEM_COMPONENT_ASSEMBLIES: added trailing slash. o  Added</p><p> o MS_REF_NEWLEVELDISPLAY o Reference support for OWL export/import</p><p> o IDGN_CONVERSION_READY_ENGINES o BMF_LOCK_LEVELS_IN_DWG o BMF_LOCK_LEVELS_IN_DGN o BMF_SHOW_CLASS_NAME_FOR_COMPONENT_MANAGER_DISPLAY o PUBLISH_IDGN_SCHEMA_NAMES o PID_REMOVE_JOIN_ADD_ELEMENT_TO_MODEL o BMF_PLANT_ITEM_IMPORT o PID_FORCE_NOZZLE_ROTATE_ON_PLACEMENT o PID_EQUIPMENT_CONNECTPOINT_DRAG_DISCONNECT_IN_SPACE o Additional schema names</p><p>. BMF_INFORMATIONAL_PIPING_COMPONENT_CLASS_NAME . BMF_INFORMATIONAL_SEGMENT_HAS_PIPING_COMPONENT_RELATIONSHIP_CLASS_NAME . BMF_INFORMATIONAL_PIPING_REDUCER_NAME . BMF_INFORMATIONAL_COMPONENT_CONNECTS_TO_SEGMENT_NAME . BMF_OFFPAGE_RELATIONSHIP_CLASS_NAMES o Optional currently not set . BMF_DEFINED_CUSTOM_ATTRIBUTE . AP_ALTERNATE_MISSING_FIELDS_XML_FILE_NAME  Removed</p><p> o MS_GUIDGNLIBLIST o BMF_SYSTEM_COMPONENT_ASSEMBLIES: duplicate entry</p><p>Projects The following PCF Files have been modified: OPPowerPID_Imperial.pcf OPPowerPID_ISO.pcf OPPowerPID_Metric.pcf</p><p>Changes list below are reflected for each project file.  Changed variables: o _BMF_PROJECT_VERSION changed to 08.11.09 o BMF_PROJECT_COMPONENT_ASSEMBLIES added trailing backslash for PW  Added variables: o OWL_PROJECT_UNIT_SUPPLEMENTAL o OWL_SCHEMA o BMF_MULTILINE_LINESPACING o BMF_MULTILINE_JUSTIFICATION</p><p>OPPowerPID_Imperial Project</p><p>Dataset files  cell o Bom.cel – changed column size for tag number field of line list o Fittings.cel – rupture disk o Fittings.cel.sch.ecinstance.xml . Added Fitting_Flange_Connection . Modified FITTING_EJECTOR, FITTING_EXHAUST_HEAD, FITTING_RUPTURE_DISK . Added DisplayLabel to FITTING_END_CAP, FITTING_END_PLUG, FITTING_BLIND_FLANGE, FITTING_BREATHER, FITTING_VENT_COVER, FITTING_VENT_SILENCER . Removed FITTING_BLANK, FITTING_CLOSED_FIGURE8, FITTING_OPEN_FIGURE8 o Miscellaneous.cel – added annotations with tag sets o Fittings.cel.sch.ecinstance.xml . Added DisplayLabel to Utility_Connector, Drain_Connector_Closed, Drain_Connector_Open, Sample_Connection, Purge_Connection  dgnlibs o Pidprojectsymbols.dgnlib . Under Conformance Tools, added  Convert Pipe Run  Remove Join</p><p> o PIDProjectTemplates.dgnlib  reports o CrystalTemplates\PipeLineListTemplate.rpt & Pipelinetemplate.rpt changed for longer tag o ReportDefinition\reports.ecinstance.xml . modified DGN_REPORT_TEMPATE  schemas o OpenPlant_PID_Supplemental_Imperial.01.01.ecschema.xml . ANGLE_CONTROL_VALVE, FOUR_WAY_CONTROL_VALVE, INLINE_CONTROL_VALVE, THREE_WAY_CONTROL_VALVE classes: added SPECIFIC_TYPE property . ANNOTATION_COMPONENTS class:  removed ECBusinessKeyGroup custom attribute  added ASSOCIATED_ITEM_LIST_POINTER custom attribute . AVERAGING_PITOT_TUBE_FLOW_METER, TARGET_FLOW_METER, VORTEX_FLOW_METER, Y_STRAINER classes: added FLOW_DEPENDENT property . Added classes: BASE_EQUIPMENT_ANNOTATION, BASE_PIPE_LINE_ANNOTATION, EQUIPMENT_ANNOTATION_ALT1, EQUIPMENT_ANNOTATION_ALT2, EQUIPMENT_ANNOTATION_ALT3, INSTRUMENT_LINE_LIST, PIPE_LINE_ANNOTATION_ALT6, PIPE_LINE_ANNOTATION_ALT7, SEGMENT_TERMINATION . CONTROL_VALVE class: changed REPLACE_ENABLED to True . EQUIPMENT class: added properties INSULATION, EQUIPMENT_INSULATION_THICKNESS, PLANT_AREA, SERVICE, & UNIT . EQUIPMENT_INSULATION class: added INSULATION_TEXT property . FLOW_NOZZLE_METER class:  Removed MIRROR_ENABLED property  Added FLOW_DEPENDENT property . FOUR_WAY_VALVE class: changed SPECIFIC_TYPE’s DefaultValue . INSTRUMENT class: DEVICE_TYPE_CODE property: added ExtendType and BMF_PROP_CUSTOM_ATTRIBUTES custom attributes . INSTRUMENT_ANNOTATION & INSTRUMENT_PARAMETRIC classes: BUBBLE_LOCATION property: removed ExtendType custom attribute . PID_DOCUMENT class: changed SCHEMA value . PIPE_LINE_ANNOTATION class:  Removed BMF_CAD_CUSTOM_ATTRIBUTES & CustomImageSpecification custom attributes  Removed SIZE, NAME, PIPELINE_NAME, SPECIFICATION properties  Added TEXT property . PIPE_LINE_ANNOTATION_ALT1, PIPE_LINE_ANNOTATION_ALT2, PIPE_LINE_ANNOTATION_ALT3, PIPE_LINE_ANNOTATION_ALT4, PIPE_LINE_ANNOTATION_ALT5 classes:  Removed BMF_CAD_CUSTOM_ATTRIBUTES custom attribute  Added ALTERNATE_DISPLAY_LABEL & TEXT properties  Removed PIPELINEANNOTATION property . PIPE_REDUCER class: added NAME property . PIPELINE_LIST class: added DISCHARGE_PIPING_SYSTEM to list . PIPING_INSULATION class:  Added CalculatedECPropertySpecification custom attribute  Modified BMF_ANNO_CUSTOM_ATTRIBUTES custom attribute  Removed Category custom attribute . PIPING_NETWORK_SEGMENT class: added properties INSULATION, INSULATION_THICKNESS . modified INSTLINE_PNEUMATIC class . STOP_CHECK_CONTROL_VALVE class: changed CellName . VALVE_USER_CELL class: added SCHEMATICS_COMPONENT_CUSTOM_ATTRIBUTES custom attribute o PSPid_ansi_Conversion.01.01.ecschema.xml . instline_pneubinary, instline_pneumatic classes: renamed TARGET_CLASSNAME  seed\seed_eng.dgn</p><p>Workfiles files</p><p>Models\pid_example.dgn OPPowerPID_ISO Project</p><p>Dataset files  cell o bom.cel o equipment.cel o equipment.cel.sch.ecinstance.xml – added SEGMENT_TERMINATION o fittings.cel.sch.ecinstance.xml . removed 00839B, 00840A, 00840B, 00841A, 00839B, 05774A, 00581A, 05776A, 05710A, 00839A . modified 05718A o miscellaneous.cel – added annotations with tag sets o valves.cel – modified angle reducing valve cells: 00595A & 00597A o valves.cel.sch.ecinstance.xml - added 00585A  dgnlibs o Pidprojectsymbols.dgnlib . Under Conformance Tools, added  Convert Pipe Run  Remove Join</p><p> o PIDProjectTemplates.dgnlib  Schemas o OpenPlant_PID_Supplemental_ISO.01.01.ecschema.xml . ACTUATOR_LIST class: added spring actuator to list . ANGLE_CONTROL_VALVE, BALL_CONTROL_VALVE, BUTTERFLY_CONTROL_VALVE, BUTTERFLY_VALVE, COCK_CONTROL_VALVE, FOUR_WAY_BALL_CONTROL_VALVE, FOUR_WAY_BALL_VALVE, FOUR_WAY_COCK_CONTROL_VALVE, FOUR_WAY_COCK_VALVE, FOUR_WAY_CONTROL_VALVE, FOUR_WAY_GENERAL_CONTROL_VALVE, FOUR_WAY_GENERAL_VALVE, FOUR_WAY_GLOBE_CONTROL_VALVE, FOUR_WAY_GLOBE_VALVE, FOUR_WAY_PLUG_CONTROL_VALVE, FOUR_WAY_PLUG_VALVE, GATE_CONTROL_VALVE, GLOBE_CONTROL_VALVE, INLINE_CONTROL_VALVE, PLUG_CONTROL_VALVE, THREE_WAY_BALL_CONTROL_VALVE, THREE_WAY_BALL_VALVE, THREE_WAY_COCK_CONTROL_VALVE, THREE_WAY_COCK_VALVE, THREE_WAY_CONTROL_VALVE, THREE_WAY_GENERAL_CONTROL_VALVE, THREE_WAY_GENERAL_VALVE, THREE_WAY_GLOBE_CONTROL_VALVE, THREE_WAY_GLOBE_VALVE, THREE_WAY_PLUG_CONTROL_VALVE, THREE_WAY_PLUG_VALVE, classes: added SPECIFIC_TYPE property . ANGLE_PRESSURE_SAFETY_VALVE, CONCENTRIC_PIPE_REDUCER, ECCENTRIC_PIPE_REDUCER, INLINE_PRESSURE_SAFETY_VALVE, classes: DISPLAY_TEXT property: modified CalculatedECPropertySpecification custom attribute . ANNOTATION_COMPONENTS class:  removed ECBusinessKeyGroup custom attribute  added ASSOCIATED_ITEM_LIST_POINTER custom attribute . Added classes: BASE_EQUIPMENT_ANNOTATION, BASE_PIPE_LINE_ANNOTATION, EQUIPMENT_ANNOTATION_ALT1, EQUIPMENT_ANNOTATION_ALT2, EQUIPMENT_ANNOTATION_ALT3, INSTRUMENT_LINE_LIST, PIPE_LINE_ANNOTATION_ALT6, PIPE_LINE_ANNOTATION_ALT7, PIPING_INSULATION, SPEC_CONTROL_VALVE_MAPPING_FOR_OPENPLANT_SPECS, . END_CONDITIONS_LIST class: changed welded class name . EQUIPMENT class: added properties INSULATION, EQUIPMENT_INSULATION_THICKNESS, PLANT_AREA, SERVICE, & UNIT . EQUIPMENT_INSULATION class: added INSULATION_TEXT property . INLINE_VALVE class: removed GENERAL_TYPE property . VALVE class: added GENERAL_TYPE property . INSTRUMENT class: DEVICE_TYPE_CODE property: added ExtendType and BMF_PROP_CUSTOM_ATTRIBUTES custom attributes . Removed INSTRUMENT_ELLIPSE, INSTRUMENT_INTERLOCK, INSTRUMENT_MISC_PILOTLIGHT, INSTRUMENT_OVAL, INSTRUMENT_SQUARE, . INSTRUMENT_PARAMETRIC classes: BUBBLE_LOCATION property: removed some entries from StandardValues list . PID_DOCUMENT class: changed SCHEMA value . PIPE_LINE_ANNOTATION class:  Removed CustomImageSpecification custom attributes  Removed SIZE, NAME, PIPELINE_NAME, SPECIFICATION, PIPELINEANNOTATION properties  Added ALTERNATE_DISPLAY_LABEL & TEXT properties . PIPE_LINE_ANNOTATION_ALT1, PIPE_LINE_ANNOTATION_ALT2, PIPE_LINE_ANNOTATION_ALT3, PIPE_LINE_ANNOTATION_ALT4, classes:  Added ALTERNATE_DISPLAY_LABEL & TEXT properties  Removed PIPELINEANNOTATION property . PIPE_LINE_ANNOTATION_ALT5 class:  Added ALTERNATE_DISPLAY_LABEL & TEXT properties  Removed SIZE, PIPELINE_NAME, SPECIFICATION, PIPELINEANNOTATION properties . PIPE_REDUCER class: NAME property:  Removed CalculatedECPropertySpecification custom attribute  Added Category & PROPERTY_DISPLAY_FILTERS custom attributes . PIPING_INSULATION_NOBREAK class: removed INSULATION_TEXT and INSULATION_THICKNESS_TEXT properties . PIPING_NETWORK_SEGMENT class: added properties INSULATION, INSULATION_THICKNESS . PRESSURE_REDUCING_VALVE class: added SIZE property . PRESSURE_SAFETY_VALVE class:  Modified CalculatedECPropertySpecification custom attribute  Added SPECIFIC_TYPE property o PSPid_iso_Conversion.01.01.ecschema.xml . instline_pneubinary, instline_pneumatic classes: renamed TARGET_CLASSNAME  seed\pid_seed_iso.dgn</p><p>Workfiles files</p><p>Models\pid_example.dgn</p><p>OPPowerPID_Metric Project</p><p>Dataset files  dgnlibs o Pidprojectsymbols.dgnlib . Under Conformance Tools, added  Convert Pipe Run  Remove Join o PIDProjectTemplates.dgnlib  seed\pid_seed_metric.dgn  see also OPPowerPID_Imperial Project’s cell and schemas changes above Workfiles files</p><p>Models\pid_example.dgn</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    17 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us