Foul Sewerage Design Calculations

Foul Sewerage Design Calculations

<p>Foul Sewerage Design Calculations</p><p>The following calculations are in accordance with ‘Sewers for Adoption’ and BS 752- 4.</p><p>From BS752-4, Domestic Flow Rate= 150-300 litres/ occupant/ day. Therefore, average taken of Domestic Flow Rate = 225 l/p/d </p><p>Domestic Peak Design Flow Rate = 6 x Domestic Flow Rate</p><p>Number of Occupants per Flat = 1.5 Number of Flats on Plot = 17</p><p>Therefore:- </p><p>Domestic Flow Rate = (225 x 1.5 x 17)/ (3600 x 24) = 0.04427 l/s</p><p>Domestic Design Flow Rate = 6 x 0.88542 = 0.265625 l/s </p><p>Design Steps</p><p>1. The foul water system design layout was discussed and sketched out, in order to establish the amount of properties to flow into each pipe. 2. The flows were then added together, at the points where pipes join one another at manholes, to calculate the cumulative flow in the system. 3. In order to achieve a self-cleansing pipe, a minimum velocity of 0.75m/s at one third Design Flow rate is required. 4. Pipe diameters and gradients were initially set at the minimum allowable values, in accordance with ‘Sewers for Adoption’. Clause 2.11 states that the minimum pipe diameter, for a pipe servicing more than 10 properties is 150mm. 5. Using a roughness value of 1.5mm, Hydraulic charts from ‘Tables for Hydraulic Design of Pipes and Sewers’ were used to determine the velocity and discharge of the pipe when full. 6. The proportional Discharge and Depth could then be found, and used to establish the Proportional Velocity at 2DWF. This had to be above the minimum of 0.75m/s, otherwise the pipe had to be redesigned. Where the pipe already met minimum diameter and hydraulic gradient requirements, a value of under 0.75m/s was acceptable. 7. Pipe gradients and depths were checked with the topography of the land to ensure that pipes were at a minimum depth of 1.2m below ground level and a maximum of 6m below ground level. 8. A Rising main was required in the design, and a suitable pump and wet well designed in accordance with this. 9. A Manhole Schedule, detailing the types and levels of Manholes to be used was then produced.</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us