2011 Oregon Residential Specialty Code

2011 Oregon Residential Specialty Code

<p> ARCH 132 2011 Oregon Residential Specialty Code Class/Homework Assignment Chapter 5 Floors Name: ______Date: ______</p><p>A wood floor meets fire protection requirement if a minimum ______thick sheathing is used. R ______</p><p>Blocking in floor systems shall be a minimum of _____ inches thick. R ______</p><p>Floor Joists or beams shall have a minimum ______inches bearing on wood and____ inches on concrete R ______</p><p>Floor Joists from opposite sides that lap on a center bearing support must lap a minimum _____ inches and be nailed together with a minimum of _____ 10d nails. R ______</p><p>Ends of joists supported laterally by solid blocking must be full depth and ___ inches nominal thick. R ______</p><p>A (#2) 2 x 12 floor joist, douglas fir-larch, dead load 20 psf, @ 16" O/C spacing will span ____ Table R ______</p><p>List the features that determine the span distance for dimensional lumber floor joist ______Table R ______</p><p>The ratio of backspan for a cantilever floor joist supporting exterior light frame, bearing wall and roof shall be at least ratio of ______Table R ______Table R 502.5(1) Exterior Bearing Wall, Girder/Header Span tabulated values assume a # _____ grade lumber.</p><p>Bridging is required in floor Joist exceeding a nominal _____ x ______inches. These perpendicular lateral supports shall be placed at intervals not exceeding ______feet ______</p><p>Framed openings in floors may have a single header and trimmer the same size as the floor joists when the framed opening does not exceed___ feet. R ______</p><p>Notches in floor joist are not permitted in the center ______of the joist length. The depth of a floor joist notch shall not exceed the nominal width divided by ______. The width of the notch shall not exceed the end one third of the joist divided by _____. Figure R ______</p><p>Beams must be connected to posts by gusset either of the following materials 1. ______2. ______3. ______Figure R ______</p><p>The width of post to beam gussets must be equal to or greater than ______Figure R ______</p><p>The length of the gusset shall be at least ____ times the width or depth of the beam. Figure R ______</p><p>Beams that splice on posts shall have gussets on ______of the beam. Figure R ______</p><p>Posts 4' to less than 8' shall have gussets on ______plus a minimum ______diagonal brace placed at _____ degrees to the post and beam. Figure R ______</p><p>Holes may drilled in joist up to ______of the actual (nominal) depth. Figure R ______</p><p>5 The maximum O/C joist span for /8" plywood subfloor sheathing rated 40/20 is ______inches. Table R ______</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us