Using Handheld Electronic Test Tools

Using Handheld Electronic Test Tools

<p> Module 2 Basic electrical measurements Using handheld electronic test tools Goals of this presentation • Understand safety specifications and how to operate handheld electronic testers in a safe manner • Understand how handheld electronic testers and accessories perform basic measurements • Learn how to set a digital multimeter (DMM) to the correct function and range for a given measurement • Learn how to measure a variety of electrical parameters and test electrical components • Determine the proper measurement tool for safe and accurate measurements • Understand the differences between average responding and true-rms measurement on non-linear loads Digital multimeter basics Agenda • Chapter 1: A first look at the DMM • Chapter 2: Multimeter safety • Chapter 3: Multimeter specifications • Chapter 4: Multimeter measurements • Ohm’s Law: basic volts, amps, ohms measurement • Special functions: Min/Max, Peak Hold • Voltage: understanding high input impedance • Current: using current clamps • Resistance: DMM source voltage and multiple sources • Testing components: diodes, caps • Measuring temperature • Chapter 5: Non-linear loads • True-rms vs. average-sensing A first look at the digital multimeter • Visual inspection • Front panel symbols • Hands-on safety inspection: • Test leads and probes • Amps inputs: fuses • Volts/Ω inputs: overload protection Front panel features: • Volts / Ω / inputs How is this input protected? • Amps, mA, mA inputs How is this input protected? • CAT IV - safety rating • Range: select manual ranging • button Second function • button Hold function Check out the back... Look at the back of the meter: • Safety warning • Fuse ratings How are fuses specified? • Certifications • Battery access Front Panel Symbols Symbol Meaning V V dc V V ac mV Millivolts (.001 V or 1/1,000 V) A Amps mA Milliamps (.001 A or 1/1000 A) µA MicroA (.000001 A or 1/1,000,000 A) Ω Resistance (Ohms) k Ω, M Ω Kilo-ohms, megohms ) )) ) Continuity beeper Front panel symbols Symbol Meaning Capacitance (uF: microfarads, (nF: nanofarads) Diode test Hz Hertz (cycles/sec) dB Decibels Range Manual measurement ranging Hold TouchHold/AutoHOLD - last stable reading MIN MAX Highest, lowest recorded readings Dangerous voltage levels Caution: see manual TouchHold Displays last stable reading • Turn dial to Vdc • Press Hold • Take measurement • Remove probes • Press hold a second time and you are in Autohold • Turn dial to Ω Press Hold Measure resistor Remove probes Measure second resistor First look at the DMM Summary • What we learned: • Meaning of front panel symbols • Back panel safety warning and other info • TouchHold & Autohold functions -- how they work Multimeter safety • Test leads & probes • Fuses • Overload protection • IEC 61010 standard Safety inspection Test leads and probes Check test lead resistance: Step 1: Insert leads in V/  and COM inputs Step 2: Select  , touch probe tips Good leads are 0.1 - 0.5  How do you check a single test lead? Visually check for: • New category rating (CAT III-1000 V or 600 V CAT IV recommended) • Double insulation • Shrouded connectors, finger guards • Insulation not melted, cut, cracked, etc. • Connectors not damaged: no insulation pulled away from end connectors • Probe tips: not loose or broken off Safety inspection Amps inputs need fuses • In a power circuit, use current clamp accessory or stand alone clamp meter • In low energy ckt, 10 A or less, open the circuit: • Measure in series (current is the same in a series circuit). The amps circuit resistance must be small to have a minimal effect on the current. This low impedance input requires fuse protection. Safety inspection Checking meter fuses on most meters Step 1: Plug test lead in V/  input. Select  Step 2: Insert probe tip into mA input and read value Step 3: Insert probe tip into A input and read value Is the fuse okay? What would an open fuse read? Safety inspection High impedance on Volts/ inputs • Volts measurements need high impedance circuit • Voltage measurements are in parallel Voltage is the same across each parallel branch • Parallel circuits divide current: High impedance branch = less current Low impedance branch = more current Safety inspection Overload protection on volts inputs</p><p>With leads in V/  and COM inputs:</p><p>Step 1: Select V and put probes in a live outlet. Will you damage the meter if you...</p><p>Step 2: Select mV Step 3: Select  Step 4: Select A. Overload protection is only to the DMM’s rated voltage. Common DMM / tester hazards • Arc from transients (lightning, load switching) Protection: Independent certification to meet CAT III-1000 V or CAT IV 600 V • Voltage contact while in continuity or resistance Protection: Overload protection in ohms up to the meter’s volt rating • Measuring voltage with test leads in current jacks Protection: High energy fuses rated to the meter’s voltage rating Use meters / testers without current jacks • Shock from accidental contact with live components Protection: Test Leads double insulated, recessed / shrouded, finger guards, CAT III – 1000 V. Replace when damaged • Using meter or tester above rated voltage Protection: Good karma Multimeter safety Summary • What we learned: • How to check for good test leads • Why amps inputs need fuse protection • Low input impedance circuit • How to check for open fuses in the meter • Function of overload protection on V/ inputs DMM specifications • Display • Accuracy • Range and resolution Understanding DMM display specs Display is specified as digits or as count • Digits: 3 1/2, 4 1/2, etc. • Example: 3 1/2: starting from the least significant digit, 3 “full” digits from 0-9, 1 “half” digit at less than 9. Ex: 1999 • Can be confusing: how do you specify 3999? • Count: 6000 5000 4000 3200 etc • 4000 count display reads from 0-3999 • 3200 count display reads from 0-3199 • Hands-on: 6000 count display • Select V, measure battery Understanding DMM accuracy specs Accuracy is specified in percentage • Closeness with which an instrument reading approaches the true value being measured; largest allowable error • Percentage of reading (digital multimeters) vs. percentage of scale or range (analog meters): Example: 1 % scale vs. 1 % reading % scale: If scale or range is 1000 V, an accuracy of 1 % is equal to +/- 10 V. 120 V reading could = 110-130 V % reading: 1 % accuracy with 120 V reading = 118.8-121.2 V • Least significant digit unstable: Example: Accuracy spec = +/-(1 % +2) Reading of 200.0 mV= 197.8 - 202.2 mV </p><p>Understanding DMM specs Range and resolution • Resolution is the smallest change in measured value to which the instrument will respond • As the range increases, the resolution decreases: Turn Fluke 179 to Vac and hit Range button (Auto disappears): Range: Resolution: 600.0 mV .1 mV (=1/10 mV) 6.000 V .001 V (=1 mV) 60.00 V .01 V (=10 mV) 600.0 V 0.1 V (=100 mV) 1000 V 1 V (=1000 mV) (To exit Manual Range, hold Range button for 2 secs) • For maximum resolution, choose the lowest possible range ABCs of DMM specs Summary • What we learned: • Display specifications: Digits or counts • Accuracy specifications: Percent of range or percent of reading • Range and resolution specs: Low range, high resolution (e.g.: 400.0 mV) High range, low resolution (e.g.: 400.0 V) DMM measurements Basic measurements: Ohm’s Law Special functions: Min/Max How DMMs measure voltage: Understanding high input impedance How DMMs measure resistance: No other voltage please How DMMs measure current: Using clamp-on accessories Testing components: Capacitors, diodes, LEDs How DMMs measure temperature Ohm’s Law (V=IR) Can you prove it, Mr.  • Battery voltage: V = • Resistor: R = • Calculate current: I CALCULATED = V / R = • Measure current: create series circuit with resistor and battery and measure current (use mA inputs): I MEASURED =</p><p>Special functions DMM as recorder: Min/Max/Avg • Capture sags: (>100 ms) • Fluke 179: push MIN MAX button. (Meter beeps with each new MIN or MAX) • Scroll through Max, Min and Average screens by pushing MIN MAX button. • Record voltage sag as motor is turned on. How DMMs measure voltage Measuring volt / input impedance Step 1: Meter 1 (179): Select ohms Meter 2: Select Vdc Use meter 1 to measure input impedance of meter 2. Meter 2 input Z = ______Ω Step 2: Reverse procedure Meter 1 select Vdc, meter 2 select ohms: Meter 1 input Z = ______Ω How DMMs measure voltage Advantages of High Input Z • Exercise: Gum wrapper battery • Step 1: Construct battery with foil, wet card and penny (don’t overlap penny onto foil) • Step 2: Select mV-dc and measure battery voltage How DMMs measure voltage Demonstrating “ghost” voltages • Turn meter to Hz. Lay leads parallel to power lines. What does the display read? • Voltage from hot to capacitively coupled ground: • Effect of floating ground: How DMMs measure resistance • The meter supplies voltage to the circuit • Presence of external voltage in circuit being measured causes meaningless readings and can damage a meter without overload protection • How it works: Measured V1 across a precision R1 is compared to measured V2 across an unknown Rx</p><p>How DMMs measure resistance Open circuit voltage • First measure “open circuit voltage” of meter when in ohms mode Meter 1: V (dc) mode Meter 2:  mode V OUT (METER 2) =</p><p>Reverse the procedure. V OUT (METER 1) =</p><p>• Now connect both meters in  mode across a known resistor. Both meters are sourcing voltage. What is the  reading? </p><p>How DMMs measure current Current clamp accessories • In power circuits, clamps are used to measure amps • Two types of clamps: ac or ac/dc (Scope clamps have BNC connectors: AC or AC/DC both output mV ) How DMMs measure current AC current clamp accessories • Current transformer (CT) style preferred for ac: • CT clamps have good noise immunity: recommended for ac variable speed drives and other noisy environments • How to use: use A inputs • They are CTs with 1:1000 turns ratio: 1 A on primary (circuit being measured) = 1 mA on secondary (input signal to DMM) • Connect probe to amps jacks of DMM • Select mA function on the Fluke 179 • True-rms measurements require a true-rms meter. How DMMs measure current AC/DC current clamp accessories • AC/DC clamps: use V inputs of DMM • Use Hall-effect technology: require batteries in clamp • 1 mV per amp • Select Vdc or mVdc to measure dc current • Select Vac to measure ac current • To measure ac+dc, use the following formula: • V total = Vac ² + Vdc² • Example: Vac = 5 V, Vdc = 5 V, but V total = 10 V</p><p>V total = 5² + 5² = 25 + 25 = 50 = 7.07 V • True-rms measurement (of ac current) requires a true-rms meter How DMMs measure current Measuring load current and inrush Plug the ac current clamp accessory into the meter: Fluke 179: use mA inputs Remember: 1 mA = 1 A • Select mA function • Select auto range and connect to mA input and common • Measure motor inrush current: • Select MIN MAX How DMMs measure current Single phase measurements • Measuring load current: measure hot conductor • Checking for shared neutrals: • Measure with load on and off: current in neutral with load off indicates shared N • If neutral current > hot current, indicates shared N • Ground current: • Measure hot and neutral separately. Difference is leakage current. Assumes non-shared neutral. How DMMs measure current Three phase measurements • Current imbalance on motor loads: % current imbalance = Deviation from average Average Max (of three phases) Example: A = 50 A, B = 30 A, C = 40 A Average = (50 + 30 + 40) / 3 = 40 A Max deviation = 10 A (10 / 40) x 100 = 25 % imbalance Motors should not exceed 15 % - 25 % current imbalance • Neutral currents at panelboard: • Fundamental N current caused by uneven distribution of single-phase loads among the three phases • 3rd harmonic N current from non-linear single-phase loads 3rd harmonic is additive in neutral How DMMs measure temperature Temperature accessories • Integrated temperature function • Use type K thermocouple probes (requires no adapter) • Non-contact: Infrared probe • Non-contact can measure electrically live or moving parts • 1 mV dc per ºF or ºC • 4:1 distance-to-target ratio: 4” away reads 1” circle • Internal 9 V battery (10 min. auto shut-off saves battery) • Contact: Thermocouple module • Uses mV dc function (requires input Z of 10 M  ) • Adapter for type-K thermocouple probes Comes with a general purpose bead probe • Switch selectable for ºF or ºC • Internal 9 V battery How DMMs measure temperature Temperature accessories</p><p>• Type-K thermocouple temperature probes • Mini-connectors plug into adapter • Different probes are specialized to measure: • Liquids and gels • Air and gases • Food • Surfaces including hot rollers and plates • Pipes (probe designed to clamp onto pipe) How DMMs measure temperature Some DMMs have integrated temperature measurement functions • Adapter accepts type K thermocouple probes. Remove for voltage measurement. MIN MAX temperature. • Select TEMP (C/F) Select MIN MAX. • Measure hot (Max) and cold (Min). Testing components Capacitors • Capacitors store electrical charge • Caution ! • Before measuring a cap, disconnect circuit power and make sure it’s discharged. Use Vdc to test if cap is discharged (= 0 V). • The 179 will display “disc” while discharging cap. • How it works: • The meter charges the cap with a known current for a known period of time, measures the resulting voltage (up to 1.2 V) and calculates the farads. Testing components Capacitors • Fluke 179: • Turn dial to Capacitance • Press yellow button to select • With probes in voltage jacks, measure cap</p><p>• Measurement note: • 1.0 µF (microfarads) = 1000 nF (nanofarads) • 0.1 µF = 100 nF Testing components Diodes Diodes turn ac to dc. </p><p>• A good silicon diode will have a voltage drop of approximately 0.5-0.7 V when it is forward biased (conducting). It will be open when it is reverse biased. • To test a diode, the DMM forces a test current through the diode in the forward bias direction and measures voltage drop across the diode.</p><p>Testing components • Forward bias = ____ V Red lead anode Black lead cathode • Reverse bias = ____ V Red lead anode Black lead cathode • Shorted: 0 in both directions • Open: OL in both directions Testing components • Diode forward bias = ____V (Red lead) + ---- P / N ---- - (Black lead) • Diode reverse bias = ____V (Black) - ---- P / N ---- + (Red) • LED forward bias = ____V (Red) + ----- P/N/P/N/P/N ------(Black) • Transistor: finding the base lead (Black) ------N / P / N ------(Black) + (Red) DMM measurements Summary What we learned • It’s the law: Mr. Ohm was right. • MIN MAX and other recorder functions • Voltage measurements: The ups and downs of high impedance inputs • Resistance: DMM is the only voltage source • Current: Capturing inrush current • Use of temperature accessories • Components: Capacitor and diode checks Measurement Issues with non-linear loads • True-rms vs. average-sensing • Crest factor True-rms vs. average-sensing How accurate is your meter? • When can you use an average-sensing meter and when do you need a true-rms meter? • Are you measuring a sine wave or something less ideal than a sine wave?</p><p>True-rms vs. average-sensing What does “rms” mean • Rms is the root mean square or effective heating value of any ac voltage or current waveform. • Rms is the equivalent dc heating value of an ac waveform. True-rms vs. average-sensing Average-sensing works for a perfect sinewave • An average-sensing meter assumes a non-distorted sinewave and does the following calculation: Rms value = 1.11 X average value True-rms vs. average-sensing What if the waveform is nonsinusoidal? • For this current waveform, the effective or true-rms value = 1.85 x average value • An average-sensing meter’s reading (1.11 x average) would be 40 % too low True-rms vs. average-sensing What causes nonsinusoidal waveforms? • Waveform distortion is caused by non-linear loads, which includes virtually all electronic loads: • Switching-mode power supplies (PC, office equipment) • Light switch dimmers and electronic ballast • Variable speed drives</p><p>True-rms vs. average-sensing What if the waveform is nonsinusoidal? • Average-sensing meters typically measure rms high for voltage and low for current where there is waveform distortion • True-rms meter or clamp accurately measures both distorted waveforms and sine waves</p><p>True-rms vs. average-sensing What if the waveform is nonlinear? Current measurement exercise: • Measure these loads with true-rms and avg-sense clamp, noting differences: • Linear load (hair dryer/drill) • Non-linear load (TV, monitor, PC) Voltage measurement: • Measure voltage using true-rms and average sensing meters while someone makes adjustments at the source. • When are the readings closest and when do they differ? True-rms vs. average-sensing What is crest factor? • Crest factor = Peak / rms • For ideal sinewave, CF = 1.414 True-rms vs. average-sensing What is crest factor? • For this current waveform, crest factor = 2.9 True-rms vs. average-sensing Crest factor is an indication of harmonics • For current or voltage measurements, the higher the CF, the greater the waveform distortion. • CF spec is important for accurate measurements. It is only specified for true-rms products. It is more critical for current measurements since harmonic distortion typically is higher for current than for voltage. True-rms vs. average-sensing Summary Minimum specifications for measurements on electrical power systems: • True-rms • Accurate for both linear and non-linear loads • Crest factor = 3 • Accurate for current waveforms with CF not exceeding 3 • CF = 3 at max range; CF = 6 at half-range • IEC 61010-1 CAT III-600 V • Distribution level: power distribution equipment.</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    13 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us