CONTRACTOR CHECKLIST Revised 08/01/2005

CONTRACTOR CHECKLIST Revised 08/01/2005

<p> CONTRACTOR CHECKLIST Revised 08/01/2005 Job# ______Contractor Name ______Client Name ______Address ______Phone # ______City ______Please complete where applicable Natural Gas Furnaces ______Propane ______Gas Water Heater ___ Elec. Water Heater______Retrofit ______Replacement ______Retrofit_____Replacement Limit off on high limit? Yes No CO Reading ______PPM Fan on temp.______Degrees or Timed Draft Reading ______IWC Fan off temp. ______Degrees or Timed Copper Gas lines replaced ? Yes No NA CO Reading ______PPM Temperature in Flue ______Degrees Manual Shutoff valve present? Yes No Temperature Rise Condition of venting ______Manufacturer Spec. ______Degrees Does vent/chimney draft - See Table* ______IWC Measured Spec. ______Degrees Condition of burners ______Replaced Thermocouple? Yes No NA Conditions of Ducts ______Burner door/panel in place? Yes No All rooms receiving heat ? Yes No T / P Valve operational ? Yes No Adequate return air present ? Yes No T / P Valve discharge pipe properly installed ? Yes No Draft Pressure - See Table* ______IWC Drip Leg / Sediment trap present ? Yes No Condition of vent?______Flue liner installed w/cap ? Yes No NA Mobile Homes Class B vent installed? Yes No NA Flue Collar installed? Yes No Temp in Flue ______Degrees Supply ducts attached to floor ? Yes No All heated rooms receiving heat ? Yes No Leaking gas lines replaced ? Yes No NA Defective floor registers replaced ? Yes No Copper gas lines replaced ? Yes No NA Sealed combustion system ? Yes No Uncoated Brass Flex connectors replaced ? Yes No NA Uncoated Brass Flex connectors replaced? Yes No NA Manual Gas shutoff valve present ? Yes No Gas Stoves Elec. shutoff switch present ? Yes No Manual Gas Shutoff valves present ? Yes No Drip Leg / Sediment trap present ? Yes No Uncoated Brass Flex connectors replaced? Yes No NA Rated Input ______BTU Gas Dryer Clocked Gas Input ______BTU Manual Gas Shutoff valves present? Yes No Fuel Pressure ______I W C Uncoated Brass Flex connectors replaced? Yes No NA Client Document Thermostat operational ? Yes No Sizing chart completed ? Yes No Heat Anticipator Setting ______PMI left with client ? Yes No Filter left with client? Yes No 90+ Furnaces Contractor guarantee with client? Yes No 2 pipe systems installed? Yes No NOTE: Incomplete service entries or omissions of Contractor signature and date of service may If No, Please state reason: delay payment for service rendered. ______RETROFIT INSTALLED ______IID / Vent Damper ? Yes No Technician’s Signature Set Back Thermostat ? Yes No GENERAL OBSERVATIONS ______Condition of Flame ______Wiring ______Contractor’s Signature Condition of Combustion Chamber ______Date ______Filter Replaced ? Yes No * Refer to back of Checklist for minimum draft readings at various outdoor temperatures. CONTRACTOR CHECKLIST</p><p>OIL HEAT NOTES:</p><p>Condition of Electrodes ______Stack control drop out time ______Draft over flame ?______Yes No ______Draft in Flue ? ______Yes No ______Chimney needs cleaned? ______Yes No ______Smoke test reading ______Oil Nozzle Size ______Oil Nozzle replaced ______Yes No ______Change Oil Filter ______Yes No ______Barometric Damper operational?______Yes No ______Class A vent installed?______Yes No ______Condition of Fuel Lines ______Condition of Chimney ______CO Reading ______PPM ______Efficiency ______%</p><p>ELECTRIC HEAT * Minimum draft readings at various outdoor temperature Condition of fuses ______Outdoor Temperature Draft Temperature Condition of Elements & Links ______below 21F -5-0 Pa (0.020” w.c.) Amp Draw ______21F to 40F -4.0 Pa (0.016” w.c.) Voltage ______41F to 60F -3.0 Pa (0.012” w.c.) Temp Rise - Manufacture ______61F to 80F -1.0 Pa (0.008” w.c.) Measured ______above 80F -1.0 Pa (0.004” w.c.)</p><p>Boilers</p><p>Fill Valve operational ? ______Yes No NA Expansion tank drained ?______Yes No NA System bled ?______Yes No NA NOTE: System pressure ______PSI Incomplete service entries or omissions of Low water cutoff operational?______Yes No NA Contractor signature and date of service may Low water cutoff cleaned ?______Yes No NA delay payment for services rendered. Pressure/Temp Valve operational?_____ Yes No NA Water sight glass visible & cleaned ?___ Yes No NA Circulator on Temp. ______Degrees ______Circulator off Temp. ______Degrees Technician’s Signature Pigtail removed & cleaned (steam) ? Yes No ______Condition of piping ______Contractor’s Signature All heated rooms receiving heat? Yes No DATE ______</p><p>Word Pro/h:eo/IHWAP/Forms/Furnace-Contractor- Checklist-08-01.doc</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us