<p> API SC6 BALLOT ITEM 6A-_____ 30 June 2011</p><p>Clarification Of Requirements For Standard Size Tensile Test Specimens</p><p>Proposal: </p><p>Revise Section 5.6.4.1 to read as follows: </p><p>Paragraph 5 - “ASTM A370 standard-sized, 12,5 mm (0,500 in) diameter tensile specimens shall be used to qualify carbon, low-alloy and stainless steels, unless the physical configuration of the TC prevents their use. In this case, the standard sub-size specimens referenced in ASTM A370 may be used. Either standard 12,5 mm (0,500 in) or standard sub-size specimens (see ASTM A370) may be used to qualify CRA materials.”</p><p>Revise Section 5.7.4.1 to read as follows:</p><p>Paragraph 6 - “ASTM A370 standard-sized, 12,5 mm (0,500 in) diameter tensile specimens shall be used, unless the physical configuration of the QTC prevents their use. In this case, the standard sub-size specimens referenced in ASTM A370 may be used.” </p><p>Justification: </p><p>In the current edition of API 6A / ISO 10423, Section 5.6.4.1 and Section 5.7.4.1 do not state that the “standard” specimens are ASTM standard-sized specimens, although they do state that when sub-size specimens are used, they shall be the ASTM A370 standard sub-size specimens. This leaves open the use of ISO 6892-1 standard specimens for tensile testing.</p><p>“ASTM A370” needs to be added to clarify that the only specimen sizes currently permitted are the ASTM A370 specimen sizes.</p><p>ISO 6892-1 includes different size specimens that have a higher gage length to diameter ratio. </p><p>The longer relative gage length of the ISO 6892-1 specimens can result in failure to meet the API 6A specified elongation acceptance criteria.</p><p>The use of ASTM A370 specimen sizes meets ISO 6892-1, since ISO 6892-1, section 6.1.1, paragraphs 7 and 8 state:</p><p>“The dimensional tolerances of the test pieces shall be in accordance with the Annexes B to E (see 6.2).” “Other test pieces such as those specified in relevant product standards or national standards may be used by agreement with the customer, e.g. ISO 3183 [1] (API 5L), ISO 11960 [2] (API 5CT), ASTM A370 [6], ASTM E8M [7], DIN 50125 [10], IACS W2 [13], and JIS Z2201 [14]”.</p><p>ASTM A370 specimen sizes are routinely used in the US and Europe, so this change does not impose something that is not a standard practice.</p><p>My Files\2011\API SC6 Summer Meeting\Agenda Item 7 - 6A Tensile Testing\API Ballot-Tensile Test-Haeberle.docx</p><p>Page 1 of 1</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us