Off-Pump Replacement of the Pulmonary Valve in Large Right Ventricular Ooutflow Tracts

Off-Pump Replacement of the Pulmonary Valve in Large Right Ventricular Ooutflow Tracts

<p>1207, Either, cat: 49</p><p>OFF-PUMP REPLACEMENT OF THE PULMONARY VALVE IN LARGE RIGHT VENTRICULAR OUTFLOW TRACTS: A HYBRID APPROACH Y Boudjemline 1,2 , S Schievano3, D Bonnet1,2, D Sidi1,2, P Bonhoeffer3 1Pediatic Cardiology, Necker for Sick Children Hospital, Paris, France, 2EMUI 0016, Necker University, Paris, France, 3Cardiothoracic Unit, Great Ormond Street Hospital, London, UK</p><p>Objectives: Percutaneous pulmonary valve replacement (PVR) has recently been introduced and is under investigation in humans. This technique is, however, limited to patients with a right ventricular outflow tract (RVOT) that does not exceed 22-mm in diameter. We report our experience of off-pump PVR in animals with large RVOTs using a hybrid approach. Methods: 8 ewes were included in the protocol and equally divided into 2 groups. A left thoracotomy was firstly performed and the main pulmonary artery (PA) was banded using two radio-opaque rings with a diameter of 18-mm that allowed for further PVR. We then intended to implant a valved stent either percutaneously (group 1) or through a transventricular approach (group 2). All animals were sacrificed after valve implantation. Results: The surgery allowed the pulmonary diameter to be reduced from 30 to 17.6-mm. The right ventricular pressure did not significantly increase after the reduction of the PA diameter (25 vs. 36-mmHg). Subsequent PVR through a percutaneous or a transventricular approach was always possible without any requirement of extracorporeal circulation. All devices were successfully delivered inside the PA banding and were functioning perfectly at early evaluation. Conclusions: Implantation of a pulmonary valve is possible in ewes through a hybrid approach when the RVOT exceeds 22-mm in diameter. This involves both surgeons and interventionists and allows for a staged procedure where the valvulation is performed percutaneously; or for a combined hybrid approach where the valve is implanted off-pump transventricularly during the same surgery. </p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us