Specification of 500 Ma X-Ray Machine

Specification of 500 Ma X-Ray Machine

<p>Specification of 500 mA X-Ray Machine</p><p>500 mA-125 KVP full wave solid state rectified X-Ray Generator for radiology with connectivity to image intensifier, single X-Ray Tube (Up-gradable to double tube), with buckeye table with spot film device.</p><p>X-Ray Generator</p><p>500 mA, 40 KW X-Ray Generator for Radiology/fluoroscopy/spotfilms Radiography KV Range : 40 to 125 Fu\fluoroscopy Range : 0 to 3 mA at 40/45 to 90 KV</p><p>Power rating of 500 mA at 100 KV/Radiography parameter from 40 to 125 KV range with ma & mAs range at small focus & large focus to be specified at all mA stations with THX 1 DRA Tube.</p><p>Generator Controls: Radiographic Timer Switch should have a timing range 0.01 to 5 sec.</p><p>Control should consist of:</p><p> Push on/push off button with voltmeter, mA meter.  Technique control buttons  Selected focal spot display  Quick trip overload protector  Voltage compensator  Digital display blinking in case of overloading (Protection for Tube)  Space charge compensator  Technique selector  Digital display of active KVP, mA & mAs  Protective anode braking device  Electronic protection for overload of tube H.V. Cables & HT tank  Spot filming at all mA stations  Independent fluoro KVP selector  Pre heating on the both the focus during filament boosting for tube safety  Fluoro mA selector  Fluoroscopic timer: totalizer with buzzer  Bucky controls  Hand switch with flexible long cord  Serialography 2 frames per second</p><p>Main Panel should indicate:</p><p> Incoming power line condition  Selected focal spot  Tube overload indicator-incase exposure factors exceed tube rating  Digital display of KV/MAs for radiography/spot filing selected</p><p>High Voltage Transformers</p><p> H.V. Transformer comprising of HV Rectifiers, HT Transformer, Filament Transformer  Unit should have phase balancing transformer workable on 3 phase 415 volt AC  Power supply requirement should be 400-440 V AC, 50 Hz 3 Phase</p><p>Control & HT Transformers should be suitable for two tubes in future without added expenditure.</p><p>X Ray Tube:</p><p> BEL DRA-1 double focus rotating anode Head THX 1 with DRA 1 125/20/40 tube unit 0.6 to 1.2mm. smaller focal spot will be preffered.  Aluminium filters  Light beam diaphragm with halogen lamp preferably auto shut off motorized collimator (as per BARC)  Pair of HV cables with standard length (preferably 10 meters)</p><p>Tube Column:</p><p>Should be floor to ceiling with fully counter balanced tube head with safety lock in case wire failure and capable of 360 degree convenient rotation and stops at 90 degree.</p><p>Lateral parking of fluoroscopy panel.</p><p>X Ray Table:</p><p>Motorized X-Ray Diagnostic Table with 90’ & 12’ movement alongwith spot film device with lateral parking for cassette size 8” x 10”, 10” x 12” and 14” x 14” with a grid 8:1, 40 lines per cm. All controls should be on SFD. Multi position with motorized bucky with bucky grid ratio of 10:1, 40 lines per cm with electro magnetic fully counter balanced floor to ceiling 360’ rotation with safety lock in case of wire failure.</p><p> Fluoroscopic lead glass & screen assembly size 14 x 14  Grid 14x 14 inches (grid ratio & lines/inch should be specified)  Lead rubber flaps protective  Mark cones  Adopter format/adopting kit for 14 x 14 cassette  Lateral parking  Handgrip, foot rest, foot switch, compression band.  Motorized collimator with auto shut off system.</p><p>Accessories</p><p>Goggles-02 Nos., Lead apron (Light weight) 2 in number, gonad shield and lead shield.</p><p>Other Requirements:</p><p>1. Company should be ISO:9001 certified. 2. Complete unit should be approved by BIS & AERB-BARC 3. Company should have a minimum of 20 years experience in the field 4. Company should have a local service centre in Delhi. 5. Spares should be available for next 10 years 6. Equipment should have complete guarantee for one year including X-Ray Tube starting from the date of approval of equipment. 7. AMC for next five years after completion of guarantee period. 8. Price should be FOB destination & should be with complete installation whatsoever. 9. List of recent installation in Govt. Hospitals. 10. Company should provide data sheet for quoted products in accordance to AERB certification.</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    0 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us