Instruction / Installation Sheet

Instruction / Installation Sheet

DataComm Electronics, Inc. 6349 Peachtree St. Norcross, GA 30071-1725 888.223.7977 770.662.8205 www.datacommelectronics.com Instruction / Installation Sheet DataComm Electronics 1x6 Coax 4x6 Phone 4 Data Module 70-0022 . Align the mounting pins with holes in the back of the HCC panel and lock module into place. Step 1 Video . Attach a female F-connector onto the cable TV service or satellite service incoming cable. Screw the incoming cable with F-connector to the connector marked “input.” . Using F-connectors, terminate all coaxial leads that have been pulled through the top knockout to the video splitter. Align the four mounting pins with holes in the back of the panel (upper most position recommended) and snap into place. Step 2 Telephone . Pull the telephone wires into the HCC panel from one of the side knockouts. Install the cable from the telephone company demarcation point to the 110 IDC marked from Telco. Install the twisted pair cables from each location in the house to the remaining 110 IDC connectors. Match the color-coding of the wires to the colors on the 110 IDC connectors. The wires should be punched down, using an industry standard punch- down tool, to the 110 IDC connectors following the T568A wiring configuration as shown below. Line 1 is Blue, Line 2 is Orange, Line 3 is Green and Line 4 is Brown. A RJ31X port is provided for line 1 seizure by security system. White / Blue Blue White / Orange Orange White /Green Green White / Brown Brown INSTRUCTIONS ARE CONTINUED ON THE BACK SIDE OF THIS PAGE 3/14/08 Rev. 1 Instruction / Installation Sheet DataComm Electronics 1x6 Coax 4x6 Phone 4 Data Module 70-0022 Installation of 4 Port Data Ports . Pull the Cat 5 or higher rated cables into the HCC panel from one of the side knockouts. Install Cat 5 or higher rated cables from each location in the house to the 4-port passive data ports. Match the color-coding of the wires to the colors on the 110 IDC connectors. The wires should be punched down, using an industry standard punch- down tool, to the 110 IDC connectors following the T568A wiring configuration as shown on previous page. CAUTION . Never install telephone wiring during lighting storms. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. Never touch un-insulated wires or terminals unless the telephone line has been disconnected at the network interface. Use caution when installing or modifying telephone lines. IMPORTANT INSTRUCTIONS . Read and understand all instructions. Follow all warnings and instructions marked on the product. Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool. SAVE THESE INSTRUCTIONS. ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT ETL LISTED CONFORMS TO UL STD 1863 ANSI/UL STD 60950-1 3026001 CERTIFIED TO CAN/CSA STD C22.2 NO 60950-1 3/14/08 Rev. 1.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us