Operation Checklist - Boiler Safety Devices

Operation Checklist - Boiler Safety Devices

<p> DEPARTMENT OF VETERANS AFFAIRS BOILER SAFETY DEVICES - OPERATION CHECK LIST</p><p>HOSPITAL______PROJECT NO. ______DATE______BOILER NO. ______BOILER MAKE AND MODEL ______BURNER MAKE AND MODEL ______TECHNICIAN AND COMPANY ______VA REPRESENTATIVE ______Not Item OK OK Set Point - Remarks</p><p>Low Water Cutoff [ ] [ ] ______Aux. Low Water Cutoff [ ] [ ] ______High Water Alarm [ ] [ ] ______Low Water Alarm [ ] [ ] ______Low Water Cutoff Shunt Switch [ ] [ ] ______Aux. Low Water Cutoff Shunt Switch [ ] [ ] ______High Steam Press. Cutout - Recycle [ ] [ ] ______High Steam Press. Cutout - Non-Recycle [ ] [ ] ______Steam Safety Valve No. 1 - Pop [ ] [ ] ______Blowdown [ ] [ ] ______Steam Safety Valve No. 2 - Pop [ ] [ ] ______Blowdown [ ] [ ] ______Steam Safety Valve No. 3 - Pop [ ] [ ] ______Blowdown [ ] [ ] ______Steam Safety Valve No. 4 - Pop [ ] [ ] ______Blowdown [ ] [ ] ______Main Gas High Pressure Cutoff [ ] [ ] ______Low Pressure Cutoff [ ] [ ] ______Safety Shut-Off Valves Proof of Closure [ ] [ ] ______Leak Test Safety Shut-Off Valves [ ] [ ] ______Oil High Pressure Cutoff [ ] [ ] ______Low Pressure Cutoff [ ] [ ] ______High Temperature Cutoff (Heated Oil) [ ] [ ] ______Low Temperature Cutoff (Heated Oil) [ ] [ ] ______Low Atomizing Pressure [ ] [ ] ______Low Atomizing/Oil Differential Pressure [ ] [ ] ______Oil Burner Position Switch [ ] [ ] ______Safety Shut-Off Valves Proof of Closure [ ] [ ] ______Leak Test Safety Shut-Off Valves [ ] [ ] ______Cold Start/Steam Atomizing Burners [ ] [ ] ______LP Gas Ignitor Operation [ ] [ ] ______Ignitor (Pilot) Low Gas Pressure [ ] [ ] ______Leak Test Safety Shut-Off Valves [ ] [ ] ______</p><p>Forced Draft Motor Interlock [ ] [ ] ______F. D. Damper Open Wide for Purge [ ] [ ] ______Outlet Damper Open Wide for Purge [ ] [ ] ______Purge Air Flow Interlock [ ] [ ] ______Purge Timing [ ] [ ] ______Ignition Timing [ ] [ ] ______Low Fire Position Interlock [ ] [ ] ______Combustion Air Flow Interlock [ ] [ ] ______Main Flame Out - Time to Close Valves [ ] [ ] ______Ignition Flame Out - Time to Close Valves [ ] [ ] ______Minimum Ignitor Flame Test [ ] [ ] ______Scanner Not Sensing Ignition Spark [ ] [ ] ______Control Air Pressure Interlock [ ] [ ] ______Sound Level - High Fire [ ] [ ] ______Fan Motor Amps [ ] [ ] ______Low Oxygen Alarm [ ] [ ] ______Boiler Soot Blower Operation and Alignment [ ] [ ] ______Economizer Soot Blower Operation [ ] [ ] ______Flue Gas Recirculation Damper Set for Prepurge [ ] [ ] ______[ ] [ ] ______</p><p>VACO 183A 2/7/00</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us