Facilities Design, Construction, & Repair Guidelines s2

Facilities Design, Construction, & Repair Guidelines s2

<p>Brown University Revised February 10, 2004 Facilities Design, Construction, & Repair Guidelines</p><p>SECTION 08550CP -- WOOD WINDOWS</p><p>PART 1 - GENERAL</p><p>1.01 This section includes wood hung, casement, awning, dormer and basement windows.</p><p>1.02 Wood windows shall be used for restoration and custom-made replacement sashes.</p><p>1.03 All hung and projected windows require air infiltration, water resistance, uniform load structural, condensation resistance, and thermal transmittance tests.</p><p>1.04 Contractor shall submit shop drawings, finish samples, test reports, and warranties.</p><p>1.05 Samples shall be required to show fabrication techniques, workmanship, and design of hardware and accessories.</p><p>1.06 For wood window restorations mockups are required for each type of repair system specified, to demonstrate materials, methods and finished product.</p><p>1.07 The contractor shall warranty the work for a period of two (2) years from the date of acceptance by the Owner.</p><p>1.08 Defective repairs including uncured or improperly installed epoxy repairs, or millwork not properly matched to historic materials shall be removed and replaced by the contractor at no expense to the owner.</p><p>1.09 RELATED WORK</p><p>A. Section 00100 General Conditions for as-built samples</p><p>PART 2 - PRODUCTS</p><p>2.01 Windows shall be single hung.</p><p>2.02 All muntins shall be true divided light.</p><p>2.03 Renovated and historic buildings shall use appropriate hardware to match original. </p><p>2.04 Minimal hardware is the goal. </p><p>2.05 Rabbet finger pulls shall be used over pull handles or match existing.</p><p>2.06 Casement and awning windows shall be avoided in dormitories.</p><p>08550C - 1 of 2 Wood Windows Criteria & Performance Requirements Brown University Revised February 10, 2004 Facilities Design, Construction, & Repair Guidelines</p><p>2.07 A jamb liner with block and tackle balance shall be used in non-historic buildings.</p><p>2.08 Catch locks that spring clear of the upper sash are required over traditional cam locks.</p><p>2.09 Weights and chains shall be considered for historic windows.</p><p>2.10 In historically significant buildings any rope attached to window weights shall be replaced with brass chains.</p><p>2.11 Mahogany shall be used for replacement windows.</p><p>2.12 No finger joints are allowed.</p><p>PART 3 - EXECUTION </p><p>3.01 All unused cavities around frames and rough openings shall be insulated with sprayable closed cell foam Icynene or approved equal. </p><p>3.02 Entire window opening and sash shall receive new interlocking weather-seals.</p><p>3.03 In historic buildings with counterweights it shall be ensured that the weights are sufficient to properly counter the weight of the new sash. Proper balancing shall be demonstrated.</p><p>END OF SECTION</p><p>08550C - 2 of 2 Wood Windows Criteria & Performance Requirements</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us