Improving Efficiency of Commercial Buildings

Improving Efficiency of Commercial Buildings

<p> Improving Efficiency of Commercial Buildings Building Re-Tuning Log Sheets</p><p>Building Name: ______Building Owner: ______Owner Contact Information: ______Phone Number(s): ______Address: ______</p><p>Building Address: ______</p><p>City: ______State: ______</p><p>Outdoor conditions at time of building walk-down ______</p><p>Date: ______</p><p>Re-tuning Team:</p><p>Name Company Phone Number Email Address</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 1 of 42 Building Walk-down Information Log</p><p>Review Electrical and Mechanical Prints </p><p>Date: ______</p><p>Prints Available (Circle answers and add any comments):</p><p>Mechanical: Yes No Electrical: Yes No Comments:</p><p>Mechanical Prints Number of Perimeter Zones Number of Interior Floors Zones North South East West</p><p>Electrical Prints 2 Generally, record individual loads from all equipment in the building. For each equipment type or size, record the number on a separate row.</p><p>Load per unit, kW Equipment or System Number Comments (Controls – Thermostat, time clock, other) or tonnage</p><p>HVAC Equipment</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 3 of 42 Equipment or System Number Load per unit, kW Comments (Controls – Occupancy Sensor, time clock, other)</p><p>Lighting</p><p>Exterior lighting</p><p>Ancillary loads</p><p>4 Equipment or System Number Load per unit, kW Comments (Controls – Occupancy Sensor, time clock, other)</p><p>Complaint log</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 5 of 42 Room Number HVAC Equipment Complaint</p><p>Walk the Outside of the Building</p><p>Windows</p><p>6 Orientation/ Estimate of Type of Windows Condition of seals Signif Operable If operable, Other Side of Percentage (e.g., single- or and/or caulking (e.g., icant Windows? estimated Observations Building Windows double-glazed, poor, good, excellent) interi (Yes/No) percentage (e.g., broken (e.g., east, on Exterior reflective, low-e, etc.) or or open (%) windows, west, north, Wall exteri shading in south) or place but not in shadi used) ng? (Yes/ No)</p><p>HVAC System Grills</p><p>Approximate number and size of HVAC grills. Note unusual situations. PNNL-SA_95117 4/23/2013 Version 1.1 7 of 42 Orientation/Side of Estimated number of Loc Unusual situations Other Notes Building (e.g., east, west, HVAC grills atio north, south) n of Gri lls</p><p>Exterior Doors</p><p>8 Orientation/Side of Number of Doors Use of Doors Level of Usage Notable Conditions or Other Notes (e.g., doors Building (e.g., east, west, (main (light, medium, not fully closing, door slamming, building north, south) entrance, heavy) pressure checks, seals-sweeps, etc.) side entrance, service— allocate a row to each type)</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 9 of 42 10 Outside Lights</p><p>Orientation/Side of Building (e.g., east, west, Lights on during the day? (Yes/No) Purpose of lighting north, south) or Parking Lot</p><p>Exterior Electrical Boxes and Piping/Conduit penetrations</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 11 of 42 Orientation/Side of Building (e.g., east, west, Note Any Boxes, Piping or Conduits with Poor Seals, Bad Caulking, or Leaking Air Noise. north, south) or Parking Lot Note if Thermal image or picture taken</p><p>Problem Location</p><p>Walk down the attic and crawl space of the building</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 12 of 42 Attic Space - Is the attic accessible? (Circle one) Yes or No Comments:</p><p>Area of the attic or side of Are the attic vents open? Is there insulation missing Is there evidence of water Is there any abandon the building: Y/N or falling down? Y/N leaks or water damage? ductwork, venting, or Y/N equipment in the attic Take pictures or thermal images of area if yes is answered in the space? Y/N following columns</p><p>Crawl Space- Is the crawl space accessible? (Circle one) Yes or No Comments:</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 13 of 42 Area of the crawl space or Are the crawl space vents Is there insulation missing Is there evidence of water Is there any abandon side of the building: open? Y/N or falling down? Y/N leaks or water damage? ductwork, venting, or Y/N equipment in the crawl Take pictures or thermal images of area if yes is answered in the space? Y/N following columns</p><p>Other Conditions</p><p>Condition of Exposed Ductwork </p><p>Identify gaps, leaks, unusual vibrations and holes in flex couplings</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 14 of 42 Problem Condition Location Description and Notes</p><p>Noises</p><p>Note any unusual noises such as squeals, high air leakage, thumping, unusual vibrations, or extreme quiet. For fans note, if they sound overloaded or extremely quiet.</p><p>Kind of Noise Location or Source Description and Notes</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 15 of 42 Walk down the Roof</p><p>Is the roof white? Circle one (Y/N)</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 16 of 42 Are there any thermal images of the roof? Circle one (Y/N) </p><p>If yes how many? </p><p>Is there any heat trace in the gutters or the scoopers? Circle one (Y/N) </p><p>Are there controls for the heat trace? Circle one (Y/N) </p><p>Do the controls work properly? Circle one (Y/N) </p><p>Comments: </p><p>Walk Down Mechanical</p><p>HVAC Equipment (packaged units, packaged air handlers, etc.)</p><p>Type of Equipment Equipment General Condition (Poor, Notes on Condition (missing exterior panels, seals missing around access</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 17 of 42 Name Good, Excellent) doors, missing condenser fans, poor general maintenance, etc.)</p><p>Coils, Filters, Dampers, Belts, Doors and Valves</p><p>Record dirty/plugged or damaged coils and filters, damaged or frozen dampers, squealing belts, water leaks, valves not opening or closing fully, valves leaking, bypasses or unmatched wire colors, etc.</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 18 of 42 Component Observed Condition and Notes</p><p>Exhaust Fans</p><p>Approximate Fan Number Application, if Known Exhausting? (Yes/No) Identify any that are not. Are there controls on the Size (bathroom exhaust, kitchen, exhaust fans (time clocks, interlock to thermostat, etc).</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 19 of 42 lab exhaust, etc.)</p><p>Walk Inside of Building</p><p>Lighting</p><p>Type of hallway lighting: ______</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 20 of 42 Average number of fixtures per hallway:</p><p>Lighting level in hallway</p><p>Average number of lamps per fixture:</p><p>Type of office lighting: ______</p><p>Average number of fixtures per office:</p><p>Lighting level in office</p><p>Average number of lamps per fixture:</p><p>Other types of other indoor lighting: ______</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 21 of 42 Hallways and Offices/Room (one page per hallway; make sufficient copies in advance)</p><p>Floor Hallway Type of Heating, If Any Thermal Conditions In Hallway (cool, Measured Thermal Feel Compared to Identifier comfortable, warm, stuffy) Temperature or Offices on the Hallway (About Thermal images the same, cooler, or warmer) (F)</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 22 of 42 Office/ Use of Thermost Thermost Perimeter or Discharge Discharg Room Air Port Corner Office/ Ligh The Space (e.g., at in at Interior (P or Duct e Air Temp (F) able ting rma Room office, Room? Location I) Register Temp Hea Room? (Yes/No) Occ l Number conference (Yes/No) (OK, Open, (F) ters upa ima room, etc.) blocked, Closed, Use ncy ge near heat Covered, d Sen and source, etc. (Yes sors /or etc.) /No ? pict ) (No ure , s Yes hav OK, e hid bee den n ) tak en (Y/ N) </p><p>PNNL-SA_95117 4/23/2013 Version 1.1 23 of 42 HVAC Unit Thermostats; make sufficient copies in advance)</p><p>HVAC Equipment #</p><p>Type of heating and cooling:</p><p>Programmable: (Make and Model)</p><p>Type of Thermostats: (5+2, 5+1+1, 7)</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 24 of 42 HVAC Equipment #</p><p>Is the thermostat programmed? Is the thermostat in an override state?</p><p>Does the thermostat have control of the economizer (integrated)?</p><p>Monday: Period 1: ( Start Time/ Heating/ Cooling Setpoints)</p><p>Monday: Period 2</p><p>Monday: Period 3</p><p>Monday: Period 4</p><p>Tuesday: Period 1</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 25 of 42 HVAC Equipment #</p><p>Tuesday: Period 2</p><p>Tuesday: Period 3</p><p>Tuesday: Period 4</p><p>Wednesday: Period 1</p><p>Wednesday: Period 2</p><p>Wednesday: Period 3</p><p>Wednesday: Period 4</p><p>Thursday: Period 1</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 26 of 42 HVAC Equipment #</p><p>Thursday: Period 2</p><p>Thursday: Period 3</p><p>Thursday: Period 4</p><p>Friday: Period 1</p><p>Friday: Period 2</p><p>Friday: Period 3</p><p>Friday: Period 4</p><p>Saturday: Period 1</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 27 of 42 HVAC Equipment #</p><p>Saturday: Period 2</p><p>Saturday: Period 3</p><p>Saturday: Period 4</p><p>Sunday: Period 1</p><p>Sunday: Period 2</p><p>Sunday: Period 3</p><p>Sunday: Period 4</p><p>Non-Programmable:</p><p>HVAC Equipment #:</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 28 of 42 HVAC Equipment #</p><p>Type of heating and cooling</p><p>Type of Thermostat:</p><p>Heating and cooling set points:</p><p>Occupants Complaints</p><p>Room/Office Number Complaint</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 29 of 42 Walk down Additional Mechanical area</p><p>Inspect each pump and record the information indicated in the table. </p><p>Pumps</p><p>Pump Pump Pump Is pump Unusual Vibrations? P Kind of For VFDs Name/ Running? Leaki hot ur Pump Motor (Yes/No) ng? (unable (Yes/No) p Control Running full speed or Control Identifier (Yes/ to hold os (constant modulating? overridden? No) hand on e speed or (Yes/No) it)? of VFD) If yes, P how (Yes/No) u badly m ? p (c</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 30 of 42 hi ll e d w at er , h ot w at er , co n d e ns at e)</p><p>Pump Name/Identifier Any insulation missing? Is there a picture of the Are there controls on Are the Are there any (Y/N) missing insulation? the pumps? (Y/N) controls pipes that are </p><p>PNNL-SA_95117 4/23/2013 Version 1.1 31 of 42 (Y/N) operational? leaking? (Y/N)</p><p>Water loops</p><p>For each water loop, record, the temperatures in and out of the plant, the inlet and outlet pressures or the pressure difference (if available).</p><p>Are there controls Temperature Out Pressure Water Loop Temperature In (F) Pressure In (psi) Pressure Out (psi) and are they (F) Difference (psi) operational?</p><p>Chilled Water</p><p>Hot water</p><p>Condensate</p><p>Pump Name/Identifier Any insulation missing? Is there a picture of the Are there controls on Are the Are there any (Y/N) missing insulation? the pumps? (Y/N) controls pipes that are (Y/N) operational? leaking? (Y/N)</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 32 of 42 Chillers, Boilers and Cooling Towers</p><p>For each chiller, boiler and cooling tower, record the information indicated in the table below. Copies second page of this table as necessary to provide space for all equipment.</p><p>Equipment Equipment Status General System in Current Valve Status of Valve Valve Type (running Condition automatic Load Identity or Valves (fully position in control Name or not) (poor, good, control or in Description open, part system (automatic (chiller, boiler, excellent) hand (from open, fully or in hand) cooling tower) control closed) (auto or panel)1 hand)</p><p>1 If load is not available, record the water temperature difference across the unit or the inlet and outlet water temperature for the unit.</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 33 of 42 Equipment Any insulation missing? Is there a picture of the Are there controls on the Are the controls Are there any Name/Identifier (Y/N) missing insulation? (Y/N) pumps? (Y/N) operational? pipes that are (Y/N) leaking?</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 34 of 42 Prescriptive Measures</p><p>Building Envelope</p><p>Envelope Issue/Problem/Opportunity Found Action Taken or Change Made</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 35 of 42 Indoor conditions</p><p>Indoor Conditions/ Observations Action Taken or Change Made</p><p>Issue/Problem/Opportunity Found</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 36 of 42 HVAC Equipment Distribution System</p><p>HVAC Equipment Distribution Action Taken or Change Made</p><p>Issue/Problem/Opportunity Found</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 37 of 42 HVAC Equipment</p><p>HVAC Equipment Action Taken or Change Made</p><p>Issue/Problem/Opportunity Found Issue/Problem/Opportunity Found</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 38 of 42 Lighting Measures</p><p>Lighting Action Taken or Change Made</p><p>Issue/Problem/Opportunity Found</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 39 of 42 Other Equipment</p><p>Other Equipment Action Taken or Change Made</p><p>Issue/Problem/Opportunity Found</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 40 of 42 Other Conditions/ Items</p><p>Other Conditions /Items Action Taken or Change Made</p><p>Issue/Problem/Opportunity Found</p><p>PNNL-SA_95117 4/23/2013 Version 1.1 41 of 42 PNNL-SA_95117 4/23/2013 Version 1.1 42 of 42</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    42 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us