Is It Safe to Discharge Patients the Same Day After Device Implantation

Is It Safe to Discharge Patients the Same Day After Device Implantation

<p> 1624, either, cat.48</p><p>IS IT SAFE TO DISCHARGE PATIENTS THE SAME DAY AFTER DEVICE IMPLANTATION? A PROSPECTIVE, RANDOMIZED PILOT STUDY M. Ortmann, G. Mark, E. Rhim, U. Patel, W. Ojeda, A.J. Greenspon, R.T. Ho, D. Frisch, B.B. Pavri Thomas Jefferson University Hospital, Philadelphia, PA, USA</p><p>Introduction: Patients are routinely admitted for overnight observation after uncomplicated pacemaker (PM) or defibrillator (ICD) implantation. However, a strategy of same day discharge (SDD) has never been tested prospectively. This pilot study sought to test the safety and feasibility of this strategy. Methods: Consenting patients were randomized to SDD or next day discharge (NDD) after uncomplicated implantation of a single/dual lead PM or ICD system. For all patients, post-operative chest x-ray (CXR) and electrocardiogram (ECG) were performed. SDD patients were discharged after 6 hours if ECG, CXR, and re- interrogation of the device were normal. NDD patients were monitored overnight on telemetry and discharged the following day without mandatory re-interrogation. Any complication precluded discharge until the patient was deemed clinically stable. All patients were seen approximately one month after discharge. Complications first noted after discharge were considered undetected. Results: Sixty-one patients were enrolled. Follow up was available in 90.1% of cases. See Table below for additional data and outcomes. Conclusions: This pilot study did not demonstrate a statistically significant difference in undetected complications with SDD. Enrollment was limited, possibly influencing outcomes. A larger study is required to confirm the safety of this strategy. Patient Characteristics, Procedural Characteristics, and Complications Same Day Next Day p value Discharge(SDD) Discharge(NDD) n 35 26 PATIENT NS CHARACTERISTICS Age, mean 65.5 67.3 Male, % 65.7 73.1 PROCEDURAL NS CHARACTERISTICS PM vs. ICD, % 62.9 vs. 37.1 51.9 vs. 48.1 1 vs. 2 leads, % 28.6 vs. 71.4 46.2 vs. 53.8 Subclavian vs. cephalic, % 80 vs. 20 84.6 vs. 15.4 COMPLICATIONS NS Overall, n 6 1 Undetected, n 3 1 Pneumothorax, n 1 0 Bleeding, n 1 0 Venous Thrombosis, n 1 0 Lead dislodgement, n 3 0</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    1 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us