Attachment A MODIFIED DOOR SCHEDULE (ALTERNATE BID ITEM #3) ~ This page intentionally left blank ~ Attachment A: Modified Door and Frame Schedule ~ Use for Base Bid. Door Room Door No. From To Nominal Type Mat'l Fin First Floor First Floor Fire Station 001 STAIR 1 ARCADE 3'‐0" X 6'‐8" 001 Alum AD 002 FIRE STATION EXTERIOR 3'‐0" X 6'‐8" 001 Alum AD 101a FIRE STATION EXTERIOR 13'‐0 X 13'10" 009 Alum AD 101b FIRE STATION EXTERIOR 13'‐0 X 13'10" 009 Alum AD 101c FIRE STATION EXTERIOR 13'‐0 X 13'10" 009 Alum AD 102 FIRE STATION STORAGE 2'‐6" X 8'‐0" (Pair) 005 FRP MFR 103 RESTROOM FIRE STATION 3'‐0" X 6'‐8" 003 FRP MFR 104 FIRE STATION LAUNDRY 3'‐0" X 6'‐8" 003 FRP MFR Public Restrooms 105a EXTERIOR WOMENS 3'‐0" X 6'‐8" 003 FRP MFR 105b WOMENS STALL 2'‐8" X 5'‐0" 006 FRP MFR 105c WOMENS STALL 2'‐8" X 5'‐0" 006 FRP MFR 105d WOMENS STALL 2'‐8" X 5'‐0" 006 FRP MFR 105e WOMENS ADA STALL 3'‐0" X 5'‐0" 007 FRP MFR 106a EXTERIOR MENS 3'‐0" X 6'‐8" 003 FRP MFR 106b MENS STALL 2'‐8" X 5'‐0" 006 FRP MFR 106c MENS ADA STALL 3'‐0" X 5'‐0" 007 FRP MFR 107 JANITOR MENS 3'‐0" X 6'‐8" 003 FRP MFR 108 JANITOR WOMENS 3'‐0" X 6'‐8" 003 FRP MFR Second Floor Fire department 201 LIVING AREA STAIR 3'‐0" X 8'‐0" 003 HM PTD 202 ENTRY EXTERIOR 3'‐0" X 8'‐0" 001 ALUM AD 203 DINING BALCONY 3'‐0" X 8'‐6" 002 ALUM AD 204 DINING BALCONY 3'‐0" X 8'‐6" 002 ALUM AD 205a DINING OFFICE 3'‐0" X 6'‐8" 003 WD PTD 205b BEDROOM OFFICE 3'‐0" X 6'‐8" 003 WD PTD 206 DINING BEDROOM 13'‐0" X 6'‐8" 003 WD PTD 207 HALLWAY BEDROOM 23'‐0" X 6'‐8" 003 WD PTD 208 HALLWAY BEDROOM 33'‐0" X 6'‐8" 003 WD PTD 209 HALLWAY BEDROOM 43'‐0" X 6'‐8" 003 WD PTD 210 HALLWAY BEDROOM 53'‐0" X 6'‐8" 003 WD PTD 211 HALLWAY BEDROOM 63'‐0" X 6'‐8" 003 WD PTD 212 JANITOR HALLWAY 2'‐6" X 6'‐8" (PAIR) 005 WD PTD 213 DINING HALLWAY 3'‐0" X 6'‐8" 003 WD PTD 214a HALLWAY BATHROOM 3'‐0" X 6'‐8" 003 WD PTD 214b BATHROOM STALL 3'‐0" X 6'‐8" 003 WD PTD 215 BATHROOM HALLWAY 3'‐0" X 6'‐8" 003 WD PTD 216 HALLWAY LAUNDRY 3'‐0" X 6'‐8" 003 WD PTD 217 HALLWAY ENTRY 3'‐0" X 6'‐8" 003 WD PTD 218 EXERCISE ROOM ENTRY 3'‐0" X 8'‐0" 003 WD PTD 219 DATA ENTRY 3'‐0" X 6'‐8" 003 WD PTD 220 STORAGE EXERCISE ROOM 3'‐0" X 6'‐8" 003 WD PTD 221 MECHANICAL OPEN STORAGE 3'‐0" X 8'‐0" 003 WD PTD 222 ELECTRICAL OPEN STORAGE 3'‐0" X 8'‐0" (PAIR) 004 WD PTD 223 OPEN STORAGE ENTRY 3'‐0" X 8'‐0" 003 WD PTD ~ This page intentionally left blank ~ Attachment B ROLL-UP BAY DOORS (ALTERNATE BID ITEM #4) ~ This page intentionally left blank ~ ® ® ® SPIRAL LH -HZ H IG H P ERFORMANCE L OW H EADROOM H URRICANE Z ONE D OOR Low Headroom and High Security Join Forces Against Hurricanes The Spiral Low Headroom Hurricane Zone Door brings high speed and high security Miami-Dade NOA - Certified independent to applications with unique space limitations in high velocity hurricane zones. testing and Notice of Acceptance (NOA) Whether headroom is severely limited because of low ceilings, joists or other overhead from Miami-Dade County Building Code obstructions, the LH-HZ is engineered for all types of low lintel challenges. Compliance Office - approved for use in High Velocity Hurricane Zones (HVHZ). Clean lines and a refined structural design give the Spiral LH-HZ door a stylish and high-tech look. With 192 powder coat options, the door can be customized to Low Headroom - The low lintel design compliment any color palette. Even without the custom colors, the anodized aluminum requires only 11 inches of clearance. slats will not corrode, so you can count on that look to last for many years even under the worst weather conditions, including hurricanes. High Security - Rigid, aluminum slat construction and optional integrated locking system provide unparalleled security. Fast and Smooth - Opens effortlessly at up to 60 inches per second for improved Miami-Dade County, Florida traffic flow and greater access control. NOA 08-1024.03 11/08/2012 Counterbalance incorporates custom- engineered springs without bungee cords. Lower Energy Costs - The fast opening and closing speeds minimize the air exchanged between climate controlled environments. A durable rubber membrane covers the reinforced hinges providing a tight seal. Quiet Operation - The high performance technology and low headroom angled track offer a quiet and unobtrusive operation. Total Digital Control - The highly advanced System 4™ door controller enables precise door positioning, infinite speed adjustments and total control of all door functions. ® ® ® SPIRAL LH -HZ H IG H P ERFORMANCE L OW H EADROOM H URRICANE Z ONE D OOR Model Name • Rytec® Spiral® LH®-HZ® Door Certification • Spiral SSN-HZ Miami-Dade, Florida NOA No. 08-1024.03, 11/8/2012 Florida Building Code: FL# FL6833 Size and Dimensions • Up to 16’W x 16’H • Multiple door configurations based on door size. Safety • Thru-beam photo eyes • Control-reliable electronic reversing edge Warranty • One year limited warranty on materials and workmanship. Hurricane Tested Panel Design • Rytec hurricane doors are inde- • Integral rubber weatherseal pendently tested and certified between the slats provides a to withstand missile impacts in tight weatherseal across the high velocity wind zones. entire panel. • Certified to withstand hurricane • Rubber weatherseal is replace- force winds of up to 149 mph. able for easy maintenance. • Patented hinge design allows for removal and replacement of Heavy-duty panel built to withstand missile single slat without disassembling Integral rubber weatherseal impacts in high velocity wind zones. the door panel. Unique Track Design Counterbalance System • Special track design allows you • Up to six extension springs in each side column, depending to fit the low headroom door in on the size of the door. areas with as little as 11 inches of • The springs assist the motor in opening, reducing clearance above door opening. motor wear and increasing the longevity of mechanical • Compact, variable speed mo- components. tor with soft acceleration and • Mechanical egress lever on the side column allows the deceleration and braking for door to be opened in the event of a power failure. smooth starts and stops. Travel Speed Electrical Controls • Opens at up to 60 inches per second. • System 4™ controller housed in a NEMA 4X rated enclosure with factory set parameters. • Intelligent processor monitors and controls power consumption. • Advanced self-diagnostics for troubleshooting. System 4 shown with optional rotary disconnect 888-GO-RYTEC RytecDoors.com Tel 262-677-9046 Fax 262-677-2058 One Cedar Parkway Jackson, WI 53037-0403 Specifications subject to change ©Rytec Corporation LIT.MSRNT 3-15-12 Rytec Spiral LH-HZ Door SECTION 08300 HIGH SPEED ROLLING DOORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. High-speed roll-up doors. B. Wiring from electric circuit disconnect to operator to control station. 1.02 RELATED SECTIONS A. None 1.03 REFERENCES A. NEMA - National Electrical Manufacturers Association. B. LED - Light Emitting Diode. 1.04 SYSTEM DESCRIPTION A. Motor type: AC drive, and variable speed with soft acceleration and braking. Mechanical release lever on side column allows door to be easily opened in the event of a power failure. 1.05 SUBMITTALS A. Submit the following: 1. Shop Drawings: Indicate pertinent dimensioning, anchorage methods, hardware locations, and installation details. 2. Product Data: Provide general construction, component connections and details, and electrical equipment, operation instructions, and information. 3. Samples: Submit samples of door slat material. 4. Manufacturer's Installation: Indicate installation sequence and procedures, adjustment, and alignment procedures. 1.06 MAINTENANCE DATA A. Scheduled maintenance program available to include lubrication requirements and frequency, periodic adjustments required, scheduled maintenance suggested, manufacturer data sheets, and equipment inter-connection diagrams. 1.07 REGULATORY REQUIREMENTS A. Electrical components UL listed. B. Electrical control panel NEMA approved. 1.08 QUALITY ASSURANCE A. Furnish high-speed roll doors and all components and accessories by one manufacturer. B. Specific door model used must have a proven track record of successful installations in similar applications of no less than 3 years. References to be provided upon request. 1.09 FIELD MEASUREMENTS A. Verify field measurements are as indicated on shop drawings. 1.10 COORDINATION A. Coordinate the work with installation of electric power and locations and sizes of conduit. 1.11 WARRANTY A. One year parts, one year labor. PART 2 - PRODUCTS 2.01 PRODUCTS A. Rytec Corporation Spiral LH-HZ Door. B. No substitutions permitted. 2.02 MATERIALS A. Door Panel: Double-walled, insulated, aluminum slats are 6 inches high by 1-3/16 inches thick. Integral rubber weatherseal between each of the panels. Door slats are connected by a reinforced hinge system to provide additional rigidity and security to door panel. Door curtain does not require a tensioning system for additional wind/pressure resistance. Doors which require the use of a tensioning system for additional wind/pressure resistance will not be accepted. B. Side Frames: Galvanized steel side frames with full height weatherseal on both sides to seal against door panel.
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages161 Page
-
File Size-