Item No. Quantity Unit Standard Price Total Amount

Item No. Quantity Unit Standard Price Total Amount

<p>______</p><p>Item No. Quantity Unit Standard price Total amount ______</p><p>Tender text door control units for versions TZ320 and TZ323</p><p>1.0 ...... Pcs...... € ...... €</p><p>SecuLogic TZ320BSN door control unit in bus technology With integrated control, illuminated emergency buttons, information label, key operated push button and power supply. Tested in accordance with EltVTR.</p><p>Equipment:  Control with illuminated emergency button LED indicators for operating states: - Door locked / unlocked / short-term release - Door open / closed - Alarm, pre-alarm, malfunction Coloured terminals to differentiate connections for the periphery. Plane operated, barrier free palm button with sabotage protection. Integrated weekly timer as well as automatic storage of operating state and user data up to 24 hrs after power failure. 3 programmable inputs, 2 programmable outputs  Integrated, illuminated emergency button information label  Key operated push button with 2 switch contacts, including profile half cylinder for setting the functions short-term release, permanent unlocking, locking, and for alarm reset  Power supply Mains voltage 230 V AC, Operating voltage 24 V AC, Output current max. 650 mA (for AP control units) Output current max. 350 mA (for UP control units)</p><p>Connections:  3 programmable inputs to connect the timer, fire alarm system, burglar alarm, access control, locks with cylinder contact, and much more. Function: High active, Low active and Deactive selectable depending on condition  2 programmable outputs to connect the swing door drive, motor lock, lever lock, additional door opener, optical or acoustical alarm indicator, and much more Function: Opener, closer and Deactive selectable depending on condition  Input for indirect release through external emergency buttons  Input for external key operated push button to control the operating modes  Input for feedback of door mode  Input for feedback of locking condition  Pre-adjusted for networking via GEZE BUS with visualisation software VAT220SN, control panel TE220/TTE220 and OPC interface OPC220</p><p>Functions:  Termination and re-triggering in conjunction with short-term release  Combination with GEZE swing door drives possible without additional components  Control and visualisation via visualisation software VAT220SN and control panel TE220/TTE220, and transfer to GLT via OPC interface is possible. EMA and BMA signals and the timer can be forwarded to all stations of a bus line via GEZE BUS. 5 groups each are possible.  Integrated draught lobby function (active, passive and combined). 10 groups are possible.  Forwarding of system conditions to GLT via floating outputs  Forwarding of collected reports, such as door mode, alarm and locked to GLT  Integrated buzzer for acoustical signalling for alarms and pre-alarm  Integrated weekly timer 015fdac1b4c605bfdd74a5949a4a8433.doc ______</p><p>Item No. Quantity Unit Standard price Total amount ______</p><p> Alarm memory with date and time  Automatic storage of operating state and user data up to 24 hrs after power failure.</p><p>Execution: ( ) Surface installation: Dimensions (WxHxD): 77x197x 90 mm ( ) Plastic casing in colour similar to RAL 6032 (green) ( ) Plastic casing in white aluminium colour ( ) RAL according to choice</p><p>( ) Standard with emergency button at bottom (TZ320BSN) ( ) With emergency button at top (TZ322BSN)</p><p>( ) Flush-mounted installation: Dimensions (WxHxD): 3-fold frame 81x223x62.5 mm ( ) Switch programme AS500, Jung, in alpine white ( ) Switch programme LS990, Jung, in stainless steel ( ) Switch programme E2, Gira, in white ( ) Switch programme E2, Gira, in anthracite Further switch programmes in System 55, e.g. Berker B1, B3, S1, Merten System M, Feller, or Gira E22, Event possible</p><p>Use for doors: ( ) Single-leaf ( ) Double-leaf</p><p>1.1 ...... Pcs. ..……...... € ...... €</p><p>SecuLogic TZ320SN door control unit in bus technology With integrated control, key operated push button, emergency buttons, information label and power supply. Tested in accordance with EltVTR.</p><p>Equipment:  Control with illuminated emergency button LED indicators for operating states: - Door locked / unlocked / short-term release - Door open / closed - Alarm, pre-alarm, malfunction Coloured terminals to differentiate connections for the periphery. Plane operated, barrier free palm button with sabotage protection. Integrated weekly timer as well as automatic storage of operating state and user data up to 24 hrs after power failure. 3 programmable inputs, 2 programmable outputs  Integrated emergency button information label, non-illuminated  Key operated push button with 2 switch contacts, including profile half cylinder to set the functions short-term release, permanent unlocking, locking and for alarm reset  Power supply Mains voltage 230 V AC, Operating voltage 24 V AC, Output current max. 650 mA (for AP control units) Output current max. 350 mA (for UP control units)</p><p>Connections:  3 programmable inputs 015fdac1b4c605bfdd74a5949a4a8433.doc ______</p><p>Item No. Quantity Unit Standard price Total amount ______</p><p> to connect the timer, fire alarm system, burglar alarm, access control, locks with cylinder contact, and much more. Function: High active, Low active and Deactive selectable depending on condition  2 programmable outputs to connect the swing door drive, motor lock, lever lock, additional door opener, optical or acoustical alarm indicator, and much more Function: Opener, closer and Deactive selectable depending on condition  Input for indirect release through external emergency buttons  Input for illumination of emergency button information label  Input for external key operated push button to control the operating modes  Input for feedback of door mode  Input for feedback of locking condition  Pre-adjusted for networking via GEZE BUS with visualisation software VAT220SN, control panel TE220/TTE220 and OPC interface OPC220</p><p>Functions:  Termination and re-triggering in conjunction with short-term release  Combination with GEZE swing door drives possible without additional components  Control and visualisation via visualisation software VAT220SN and control panel TE220/TTE220, and transfer to GLT via OPC interface is possible. EMA and BMA signals and the timer can be forwarded to all stations of a bus line via GEZE BUS. 5 groups each are possible.  Integrated draught lobby function (active, passive and combined). 10 groups are possible.  Forwarding of system conditions to GLT via floating outputs  Forwarding of collected reports, such as door mode, alarm and locked to GLT  Integrated buzzer for acoustical signalling for alarms and pre-alarm  Integrated weekly timer  Alarm memory with date and time  Automatic storage of operating state and user data up to 24 hrs after power failure.</p><p>Execution: ( ) Surface installation: Dimensions (WxHxD): 77x197x 90 mm ( ) Plastic casing in colour similar to RAL 6032 (green) ( ) Plastic casing in white aluminium colour ( ) RAL according to choice</p><p>( ) Standard with emergency button at bottom (TZ320SN) ( ) With emergency button at top (TZ323SN)</p><p>( ) Flush-mounted installation: Dimensions (WxHxD): 3-fold frame 81x223x62.5 mm ( ) Switch programme AS500, Jung, in alpine white ( ) Switch programme LS990, Jung, in stainless steel ( ) Switch programme E2, Gira, in white ( ) Switch programme E2, Gira, in anthracite Further switch programmes in System 55, e.g. Berker B1, B3, S1, Merten System M, Feller, or Gira E22, Event possible</p><p>Use for doors: ( ) Single-leaf ( ) Double-leaf</p><p>1.2 ...... Pcs...... ……...... € ...... €</p><p>015fdac1b4c605bfdd74a5949a4a8433.doc ______</p><p>Item No. Quantity Unit Standard price Total amount ______</p><p>SecuLogic TZ320S door control unit in bus technology With integrated control, key operated push button and emergency buttons, information label Tested in accordance with EltVTR.</p><p>Equipment:  Control with illuminated emergency button LED indicators for operating states: - Door locked / unlocked / short-term release - Door open / closed - Alarm, pre-alarm, malfunction Coloured terminals to differentiate connections for the periphery. Plane operated, barrier free palm button with sabotage protection. Integrated weekly timer as well as automatic storage of operating state and user data up to 24 hrs after power failure. 3 programmable inputs, 2 programmable outputs  Integrated emergency button information label, non-illuminated  Key operated push button with 2 switch contacts, including profile half cylinder for setting the functions short-term release, permanent unlocking, locking, and for alarm reset</p><p>Operating voltage 24 V DC. </p><p>Connections:  3 programmable inputs to connect the timer, fire alarm system, burglar alarm, access control, locks with cylinder contact, and much more. Function: High active, Low active and Deactive selectable depending on condition  2 programmable outputs to connect the swing door drive, motor lock, lever lock, additional door opener, optical or acoustical alarm indicator, and much more Function: Opener, closer and Deactive selectable depending on condition  Input for indirect release through external emergency buttons  Input for external key operated push button to control the operating modes  Input for feedback of door mode  Input for feedback of locking condition  Pre-adjusted for networking via GEZE BUS with visualisation software VAT220SN, control panel TE220/TTE220 and OPC interface OPC220</p><p>Functions:  Termination and re-triggering in conjunction with short-term release  Combination with GEZE swing door drives possible without additional components  Control and visualisation via visualisation software VAT220SN and control panel TE220/TTE220, and transfer to GLT via OPC interface is possible. EMA and BMA signals and the timer can be forwarded to all stations of a bus line via GEZE BUS. 5 groups each are possible.  Integrated draught lobby function (active, passive and combined). 10 groups are possible.  Forwarding of system conditions to GLT via floating outputs  Forwarding of collected reports, such as door mode, alarm and locked to GLT  Integrated buzzer for acoustical signalling for alarms and pre-alarm  Integrated weekly timer  Alarm memory with date and time  Automatic storage of operating state and user data up to 24 hrs after power failure.</p><p>Execution: ( ) Surface installation: Dimensions (WxHxD): 77x197x 90 mm ( ) Plastic casing in colour similar to RAL 6032 (green) ( ) Plastic casing in white aluminium colour 015fdac1b4c605bfdd74a5949a4a8433.doc ______</p><p>Item No. Quantity Unit Standard price Total amount ______</p><p>( ) RAL according to choice</p><p>( ) Standard with emergency button at bottom (TZ320S) ( ) With emergency button at top (TZ322S)</p><p>( ) Flush-mounted installation: Dimensions (WxHxD): 2-fold frame 81x152x62.5 mm ( ) Switch programme AS500, Jung, in alpine white ( ) Switch programme LS990, Jung, in stainless steel ( ) Switch programme E2, Gira, in white ( ) Switch programme E2, Gira, in anthracite Further switch programmes in System 55, e.g. Berker B1, B3, S1, Merten System M, Feller, or Gira E22, Event possible</p><p>Use for doors: ( ) Single-leaf ( ) Double-leaf</p><p>1.3 ...... Pcs...... ……...... € ...... €</p><p>SecuLogic TZ320 door control unit in bus technology With integrated control and emergency buttons, information label Tested in accordance with EltVTR. For connection to external key operated push button or GEZE IQ LOCK with cylinder contact.</p><p>Equipment:  Control with illuminated emergency button LED indicators for operating states: - Door locked / unlocked / short-term release - Door open / closed - Alarm, pre-alarm, malfunction Coloured terminals to differentiate connections for the periphery. Plane operated, barrier free palm button with sabotage protection. Integrated weekly timer as well as automatic storage of operating state and user data up to 24 hrs after power failure. 3 programmable inputs, 2 programmable outputs  Integrated emergency button information label, non-illuminated</p><p>Operating voltage 24 V DC. </p><p>Connections:  3 programmable inputs to connect the timer, fire alarm system, burglar alarm, access control, locks with cylinder contact, and much more. Function: High active, Low active and Deactive selectable depending on condition  2 programmable outputs to connect the swing door drive, motor lock, lever lock, additional door opener, optical or acoustical alarm indicator, and much more Function: Opener, closer and Deactive selectable depending on condition  Input for indirect release through external emergency buttons  Input for external key operated push button to control the operating modes  Input for feedback of door mode  Input for feedback of locking condition  Pre-adjusted for networking via GEZE BUS with visualisation software VAT220SN, control panel TE220/TTE220 and OPC interface OPC220</p><p>Functions: 015fdac1b4c605bfdd74a5949a4a8433.doc ______</p><p>Item No. Quantity Unit Standard price Total amount ______</p><p> Termination and re-triggering in conjunction with short-term release  Combination with GEZE swing door drives possible without additional components  Control and visualisation via visualisation software VAT220SN and control panel TE220/TTE220, and transfer to GLT via OPC interface is possible. EMA and BMA signals and the timer can be forwarded to all stations of a bus line via GEZE BUS. 5 groups each are possible.  Integrated draught lobby function (active, passive and combined). 10 groups are possible.  Forwarding of system conditions to GLT via floating outputs  Forwarding of collected reports, such as door mode, alarm and locked to GLT  Integrated buzzer for acoustical signalling for alarms and pre-alarm  Integrated weekly timer  Alarm memory with date and time  Automatic storage of operating state and user data up to 24 hrs after power failure.</p><p>Execution: ( ) Surface installation: Dimensions (WxHxD): 77x197x 90 mm ( ) Plastic casing in colour similar to RAL 6032 (green) ( ) Plastic casing in white aluminium colour ( ) RAL according to choice</p><p>( ) Standard with emergency button at bottom (TZ320) ( ) With emergency button at top (TZ322)</p><p>( ) Flush-mounted installation: Dimensions (WxHxD): 1-fold frame 81x223x62.5 mm ( ) Switch programme AS500, Jung, in alpine white ( ) Switch programme LS990, Jung, in stainless steel ( ) Switch programme E2, Gira, in white ( ) Switch programme E2, Gira, in anthracite Further switch programmes in System 55, e.g. Berker B1, B3, S1, Merten System M, Feller, or Gira E22, Event possible</p><p>Use for doors: ( ) Single-leaf ( ) Double-leaf</p><p>1.4 ...... Pcs...... ……..... € ...... €</p><p>015fdac1b4c605bfdd74a5949a4a8433.doc</p>

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    6 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us