![Display Hidden Notes to Specifier. (Don't Know How? Click Here) s92](https://data.docslib.org/img/3a60ab92a6e30910dab9bd827208bcff-1.webp)
<p> SECTION 15510 HEATING BOILERS </p><p>Display hidden notes to specifier. (Don't know how? Click Here)</p><p>Copyright 2016 - 2016 ARCAT, Inc. - All rights reserved</p><p>PART 1 GENERAL</p><p>1.1 SECTION INCLUDES</p><p>1.A. Packaged, cast iron, gas fired hot water commercial and residential boilers.</p><p>1.B. Packaged, cast iron, gas fired steam commercial and residential boilers.</p><p>1.C. Packaged, cast iron, oil fired, hot water commercial and residential boilers.</p><p>1.D. Packaged, cast iron, oil fired, steam commercial and residential boilers.</p><p>1.E. Packaged cast iron, electric hot water commercial and residential boilers.</p><p>1.F. Packaged stainless steel water tube high efficiency gas fired hot water boilers</p><p>1.G. Packaged stainless steel fire tube high efficiency, gas fired hot water boilers.</p><p>1.H. Knocked-down, cast iron, oil fired, hot water boilers.</p><p>1.2 RELATED SECTIONS</p><p>2.A. Section 15050 - Basic Mechanical Methods and Materials: Requirements for fittings, valves, and piping.</p><p>2.B. Section 16050 - Basic Electrical Methods and Materials: Requirements for line and low voltage wiring.</p><p>1.3 REFERENCES</p><p>3.A. American National Standards Institute (ANSI): 3.A.1. ANSI Z21.13/ CSA 4.9 - Gas-fired low pressure steam and hot water boilers. 15510-1 3.B. American Society of Heating and Refrigeration Engineers. (ASHRAE): 3.B.1. ASHRAE 103 - Method of Testing for Annual Fuel Utilization Efficiency of Residential Central Furnaces and Boilers</p><p>3.C. American Society of Mechanical Engineers (ASME): 3.C.1. ASME Boiler and Pressure Vessel Code.</p><p>3.D. CSA Group (CSA): 3.D.1. CSA 4.9 - Gas-Fired Low Pressure Steam and Hot Water Boilers. 3.D.2. CSA B140.7 - Oil-Burning Equipment: General Requirements.</p><p>3.E. Underwriters Laboratory (UL): 3.E.1. UL834 - Standard for Heating, Water Supply, and Power Boilers - Electric 3.E.2. UL 726 - Standard for Oil-Fired Boiler Assemblies</p><p>1.4 SUBMITTALS</p><p>4.A. Submit under provisions of Section 01300.</p><p>4.B. Product Data: Manufacturer's data sheets on each product to be used, including: 4.B.1. Preparation instructions and recommendations. 4.B.2. Storage and handling requirements and recommendations. 4.B.3. Installation methods. 4.B.4. Warranty.</p><p>4.C. Shop Drawings: Include system components, utility requirements and connections, relationship with adjacent construction. Include required clearances and access for servicing.</p><p>1.5 QUALITY ASSURANCE</p><p>5.A. Manufacturer Qualifications: Minimum 5 years experience manufacturing similar equipment.</p><p>5.B. Installer Qualifications: Minimum 2 years experience installing similar equipment.</p><p>5.C. Standards: Boilers shall meet the requirements of the ASME Boiler and Pressure Vessel Code.</p><p>1.6 DELIVERY, STORAGE, AND HANDLING</p><p>6.A. Store products in manufacturer's unopened packaging until ready for installation.</p><p>15510-2 1.7 PROJECT CONDITIONS</p><p>7.A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.</p><p>1.8 WARRANTY</p><p>8.A. Manufacture's standard residential limited warranty with the following warranty periods: 8.A.1. 1 year parts warranty. 8.A.2. Limited Lifetime cast-iron sections warranty. 8.A.3. 20 year boiler vessel warranty. </p><p>8.B. Manufacture's standard commercial limited warranty. 8.B.1. PRODUCTS</p><p>1.9 MANUFACTURERS</p><p>9.A. Acceptable Manufacturer: Slant/Fin Corp., which is located at: 100 Forest Dr.; Greenvale, NY 11548; Tel: 516-484-2600; Fax: 516-484-5921; Email: request info ([email protected]); Web: www.slantfin.com </p><p>9.B. Substitutions: Not permitted.</p><p>9.C. Requests for substitutions will be considered in accordance with provisions of Section 01600.</p><p>1.10 PERFORMANCE REQUIREMENTS</p><p>10.A. Gas Fired Boilers: 10.A.1. CSA design approved to ANSI Z21.13/ CSA 4.9.</p><p>10.B. Oil Fired Boilers: 10.B.1. Design certified to UL 726 and CSA B140.7</p><p>10.C. Electric Boilers: 10.C.1. Design certified to UL 834 and CSA B140.7 10.C.2. Built to the requirements of Section IV of the ASME Boiler and Pressure Vessel Code.</p><p>10.D. Cast-Iron Boilers: Built to the requirements of Section IV of the ASME Boiler and Pressure Vessel Code.</p><p>15510-3 10.E. Meet or exceed the National Appliance Energy Compliance Act.</p><p>10.F. AHRI approved ratings.</p><p>10.G. Boiler ratings with less than 300,000 Btuh input are established under ASHRAE Standard 103 as required by DOE and are verified annually by AHRI under the AHRI DOE Verification Program.</p><p>10.H. Boiler ratings with 300,000 Btuh input and greater are established by AHRI under AHRI test procedures.</p><p>10.I. Manufacturer to be holder of an ASME Certificate of Authorization and Code Stamp. </p><p>1.11 PACKAGED CAST IRON, GAS FIRED, HOT WATER COMMERCIAL AND RESIDENTIAL BOILERS</p><p>11.A. Basis of Design: Sentry S series and manufactured by Slant/Fin. Natural draft, atmospheric preassembled cast-iron heat exchanger with built in air separator, integral draft diverter, and vent damper. 11.A.1. Model S-34EDP: 11.A.1.a. Input Rating: 34 MBH (9.96 kW). 11.A.1.b. DOE Heating Capacity: 29000 BTUh (8.50 kW). 11.A.1.c. AHRI Net Output Rating: 25 MBH (7.33 kW). 11.A.1.d. Square Feet Equivalent Direct Radiation: 167 sq ft (15.51 sq m). 11.A.1.e. Annual Fuel Utilization Efficiency (AFUE): 84 percent. 11.A.1.f. Nominal Vent Diameter: 4 inch (102 mm). 11.A.2. Model S-60EDP: 11.A.2.a. Input Rating: 60 MBH (17.58 kW). 11.A.2.b. DOE Heating Capacity: 51000 BTUh (14.95 kW). 11.A.2.c. AHRI Net Output Rating: 44 MBH (12.89 kW). 11.A.2.d. Square Feet Equivalent Direct Radiation: 293 sq ft (27.22 sq m). 11.A.2.e. Annual Fuel Utilization Efficiency (AFUE): 84.4 percent . 11.A.2.f. Nominal Vent Diameter: 4 inch (102 mm). 11.A.3. Model S-90EDP: 11.A.3.a. Input Rating: 90 MBH (26.38 kW). 11.A.3.b. DOE Heating Capacity: 76000 BTUh (22.27 kW). 11.A.3.c. AHRI Net Output Rating: 66 MBH (19.34 kW). 11.A.3.d. </p><p>15510-4 Square Feet Equivalent Direct Radiation: 440 sq ft (40.88 sq m). 11.A.3.e. Annual Fuel Utilization Efficiency (AFUE): 84.2 percent. 11.A.3.f. Nominal Vent Diameter: 5 in (127 mm). 11.A.4. Model S-120EDP: 11.A.4.a. Input Rating: 120 MBH (35.17 kW). 11.A.4.b. DOE Heating Capacity: 101000 BTUh (29.60 kW). 11.A.4.c. AHRI Net Output Rating: 88 MBH (25.79 kW). 11.A.4.d. Square Feet Equivalent Direct Radiation: 587 sq ft (54.53 sq m). 11.A.4.e. Annual Fuel Utilization Efficiency (AFUE): 84.1 percent. 11.A.4.f. Nominal Vent Diameter: 6 in (152 mm). 11.A.5. Model S-150EDP: 11.A.5.a. Input Rating: 150 MBH (43.96 kW). 11.A.5.b. DOE Heating Capacity: 125000 BTUh (36.63 kW). 11.A.5.c. AHRI Net Output Rating: 109 MBH (31.94 kW). 11.A.5.d. Square Feet Equivalent Direct Radiation: 727 sq ft (67.54 sq m). 11.A.5.e. Annual Fuel Utilization Efficiency (AFUE): 83.4 percent. 11.A.5.f. Nominal Vent Diameter: 7 in (178 mm). 11.A.6. Boiler Characteristics: 11.A.6.a. Fuel type: Natural Gas. 11.A.6.b. Fuel Type: Propane. 11.A.6.c. Base: Insulated. 11.A.6.d. Base: Constructed and Insulated for placement on combustible flooring. 11.A.6.e. Built in draft diverter. 11.A.6.f. Pre-assembled insulated flush jacket. 11.A.6.g. Gas Burners: Stainless steel. 11.A.6.h. Orifices: Brass. 11.A.6.i. Manifold: Steel. 11.A.6.j. Redundant combination gas valve including manual shut-off, pressure regulator, pilot adjustment. 11.A.6.k. Pilot ignition system: Intermittent spark. 11.A.6.l. Pressure and temperature gauge. 11.A.6.m. Pressure relief valve (ASME) 30 psi. 15510-5 11.A.6.n. 2-way combination control (hi-limit and circulator relay). 11.A.6.o. Circulator: Taco 007, with 1-1/4" flange. 11.A.6.p. Circulator: Grundfos UPS 15-58F 1-1/4". 11.A.6.q. Circulator: B & G NRF 22 - 1-1/4". 11.A.6.r. Circulator: Taco 0010 11.A.6.s. Circulator: Taco 110 1-1/4" 11.A.6.t. Circulator: B & G model 100 1-1/4" 11.A.6.u. Drain cock. 11.A.6.v. Blocked Vent Safety Switch: Mounted and wired. 11.A.6.w. Rollout Safety Switch: Mounted and wired. 11.A.6.x. Outdoor reset sensor kit. 11.A.6.y. Air Package: Diaphragm expansion tank, automatic fill valve and pressure reducing valve, and automatic float air vent. 11.A.7. Control Features: 11.A.7.a. Thermal targeting technology to conserve fuel. 11.A.7.b. LWCO function - Auto or manual reset. 11.A.7.c. Thermal pre-purge option. 11.A.7.d. LED display for operational info. 11.A.7.e. Circulator relay - 3 function options.</p><p>11.B. Basis of Design: Sentinel SE series and manufactured by Slant/Fin. Natural draft, atmospheric preassembled cast-iron heat exchanger with built in air separator, and vent damper. 11.B.1. Model SE-70EDP: 11.B.1.a. Input Rating: 70 MBH (20.51 kW). 11.B.1.b. DOE Heating Capacity: 58000 BTUh (17 kW). 11.B.1.c. AHRI Net Output Rating: 50 MBH (14.65 kW). 11.B.1.d. Square Feet Equivalent Direct Radiation: 333 sq ft (30.9 sq m). 11.B.1.e. Annual Fuel Utilization Efficiency (AFUE): 82.0 percent ( 11.B.1.f. Nominal Vent Diameter: 4 in (102 mm). 11.B.2. Model SE-105EDP: 11.B.2.a. Input Rating: 105 MBH (30.77 kW). 11.B.2.b. DOE Heating Capacity: 87000 BTUh (25.50 kW). 11.B.2.c. 15510-6 AHRI Net Output Rating: 76 MBH (22.27 kW). 11.B.2.d. Square Feet Equivalent Direct Radiation: 507 sq ft (47.1 sq m). 11.B.2.e. Annual Fuel Utilization Efficiency (AFUE): 82.1 percent. 11.B.2.f. Nominal Vent Diameter: 5 in (127 mm). 11.B.3. Model SE-140EDP: 11.B.3.a. Input Rating: 140 MBH (41.03 kW). 11.B.3.b. DOE Heating Capacity: 116000 BTUh (34.00 kW). 11.B.3.c. AHRI Net Output Rating: 101 MBH (29.60 kW). 11.B.3.d. Square Feet Equivalent Direct Radiation: 673 sq ft (62.5 sq m). 11.B.3.e. Annual Fuel Utilization Efficiency (AFUE): 82.2 percent. 11.B.3.f. Nominal Vent Diameter: 5 in (127 mm). 11.B.4. Model S-175EDP: 11.B.4.a. Input Rating: 175 MBH (51.29 kW). 11.B.4.b. DOE Heating Capacity: 145000 BTUh (42.49 kW). 11.B.4.c. AHRI Net Output Rating: 126 MBH (36.93 kW). 11.B.4.d. Square Feet Equivalent Direct Radiation: 840 sq ft (78 sq m). 11.B.4.e. Annual Fuel Utilization Efficiency (AFUE): 82.2 percent. 11.B.4.f. Nominal Vent Diameter: 6 in (152 mm). 11.B.5. Model S-210EDP: 11.B.5.a. Input Rating: 210 MBH (61.54 kW). 11.B.5.b. DOE Heating Capacity: 173000 BTUh (50.70 kW). 11.B.5.c. AHRI Net Output Rating: 150 MBH (43.96 kW). 11.B.5.d. Square Feet Equivalent Direct Radiation: 1000 sq ft (92.9 sq m) 11.B.5.e. Annual Fuel Utilization Efficiency (AFUE): 82.3 percent. 11.B.5.f. Nominal Vent Diameter: 7 in (178 mm). 11.B.6. Boiler Characteristics: 11.B.6.a. Fuel type: Natural Gas. 11.B.6.b. Fuel Type: Propane. 11.B.6.c. Base: Insulated. 11.B.6.d. Base: Constructed and Insulated for placement on combustible flooring. 11.B.6.e. Pre-assembled insulated flush jacket. 11.B.6.f. 15510-7 External Draft hood. 11.B.6.g. Gas Burners: Stainless steel. 11.B.6.h. Orifices: Brass. 11.B.6.i. Manifold: Steel. 11.B.6.j. Redundant combination gas valve including manual shut-off, pressure regulator, pilot adjustment. 11.B.6.k. Pilot ignition system: Intermittent spark. 11.B.6.l. Pressure and temperature gauge. 11.B.6.m. Pressure relief valve (ASME) 30 psi. 11.B.6.n. 2-way combination control (hi-limit and circulator relay). 11.B.6.o. Circulator: Taco 007, with 1-1/4" 11.B.6.p. Circulator: Grundfos UPS 15-58F 1-1/4". 11.B.6.q. Circulator: B & G NRF 22 - 1-1/4". 11.B.6.r. Circulator: Taco 0010. 11.B.6.s. Circulator: Taco 110 1-1/4". 11.B.6.t. Circulator: B & G model 100 1-1/4". 11.B.6.u. Drain cock. 11.B.6.v. Blocked vent safety switch: Not mounted. 11.B.6.w. Motorized vent damper. 11.B.6.x. Rollout safety switch. 11.B.6.y. Outdoor reset sensor kit. 11.B.6.y.1) Air Package: Diaphragm expansion tank, automatic fill valve and pressure reducing valve, and automatic float air vent. 11.B.7. Control Features: 11.B.7.a. Thermal targeting technology to conserve fuel. 11.B.7.b. LWCO function - Auto or manual reset. 11.B.7.c. Thermal pre-purge option. 11.B.7.d. LED display for operational info. 11.B.7.e. Circulator relay - 3 function options.</p><p>11.C. Basis of Design: Galaxy GG series and manufactured by Slant/Fin. Natural draft, atmospheric preassembled cast-iron heat exchanger with built in air separator and vent damper. 11.C.1. Model GG-250HEDP: 11.C.1.a. 15510-8 Input Rating: 250 MBH (73.27 kW). 11.C.1.b. DOE Heating Capacity: 209000 BTUh (61.25 kW). 11.C.1.c. AHRI Net Output Rating: 182 MBH (53.34 kW). 11.C.1.d. Square Feet Equivalent Direct Radiation: 1211.3 sq ft (112.5 sq m). 11.C.1.e. Annual Fuel Utilization Efficiency (AFUE): 82.8 percent. 11.C.1.f. Nominal Vent Diameter: 8 in (203 mm). 11.C.2. Model GG-275HEDP: 11.C.2.a. Input Rating: 275 MBH (80.59 kW). 11.C.2.b. DOE Heating Capacity: 228000 BTUh (66.82 kW). 11.C.2.c. AHRI Net Output Rating: 198 MBH (58.03 kW). 11.C.2.d. Square Feet Equivalent Direct Radiation: 1322.0 sq ft (122.8 sq m). 11.C.2.e. Annual Fuel Utilization Efficiency (AFUE): 82.7 percent. 11.C.2.f. Nominal Vent Diameter: 8 in (203 mm). 11.C.3. Model GG-300HEDP: 11.C.3.a. Input Rating: 300 MBH (87.92 kW). 11.C.3.b. Gross Output Rating: 243000 BTUh (71.22 kW). 11.C.3.c. AHRI Net Output Rating: 211 MBH (61.84 kW). 11.C.3.d. Square Feet Equivalent Direct Radiation: 1407.0 sq ft (130.7 sq m). 11.C.3.e. Annual Fuel Utilization Efficiency (AFUE): 81.1 percent. 11.C.3.f. Nominal Vent Diameter: 8 in (203 mm). 11.C.4. Model GG-350HEDP: 11.C.4.a. Input Rating: 350 MBH (102.57 kW). 11.C.4.b. Gross Output Rating: 285000 BTUh (83.52 kW). 11.C.4.c. AHRI Net Output Rating: 253 MBH (74.15 kW). 11.C.4.d. Square Feet Equivalent Direct Radiation: 1653 sq ft (153.6 sq m). 11.C.4.e. Annual Fuel Utilization Efficiency (AFUE): 81.4 percent. 11.C.4.f. Nominal Vent Diameter: 9 in (229 mm). 11.C.5. Model GG-375HEDP: 11.C.5.a. Input Rating: 375 MBH (109.90 kW). 11.C.5.b. Gross Output Rating: 303000 BTUh (88.80 kW). 11.C.5.c. AHRI Net Output Rating: 263 MBH (77.08 kW). 11.C.5.d. 15510-9 Square Feet Equivalent Direct Radiation: 1753 sq ft (162.9 sq m). 11.C.5.e. Annual Fuel Utilization Efficiency (AFUE): 80.9 percent. 11.C.5.f. Nominal Vent Diameter: 10 in (254 mm). 11.C.6. Model GG-399HEDP: 11.C.6.a. Input Rating: 399 MBH (116.93 kW). 11.C.6.b. Gross Output Rating: 322000 BTUh (94.37 kW). 11.C.6.c. AHRI Net Output Rating: 284 MBH (83.23 kW). 11.C.6.d. Square Feet Equivalent Direct Radiation: 1867 sq ft (173.5 sq m). 11.C.6.e. Annual Fuel Utilization Efficiency (AFUE): 80.6 percent. 11.C.6.f. Nominal Vent Diameter: 10 in (254 mm). 11.C.7. Boiler Characteristics: 11.C.7.a. Fuel type: Natural Gas. 11.C.7.b. Fuel Type: Propane. 11.C.7.c. Base: Insulated. 11.C.7.d. Base: Constructed and Insulated for placement on combustible flooring. 11.C.7.e. Pre-assembled insulated flush jacket. 11.C.7.f. Flu collector. 11.C.7.g. Gas Burners: Stainless steel. 11.C.7.h. Orifices: Brass. 11.C.7.i. Manifold: Steel. 11.C.7.j. Redundant combination gas valve including manual shut-off, pressure regulator, pilot adjustment, and 100 percent shutoff. 11.C.7.k. Pilot ignition system: Intermittent spark. 11.C.7.l. Pressure, temperature, and altitude gauge. 11.C.7.m. Pressure relief valve (ASME) 30 psi. 11.C.7.n. 2-way combination control (hi-limit and circulator relay). 11.C.7.o. Hi-limit control. 11.C.7.p. Draft hood (field installed). 11.C.7.q. Circulator: Taco 0010 for GG-225 thru GG-399 X. 11.C.7.q.1) Flange for circulator: 1-1/4";1-1/2" (GG-250 thru GG-399) X. 11.C.7.q.2) Circulator manifold. 11.C.7.r. Circulator: Taco 110 (GG-225 thru GG-399) 39. 15510-10 11.C.7.s. Circulator: B&G 100 (GG-225 thru GG-399). 11.C.7.t. Drain cock. 11.C.7.u. Blocked vent safety switch: Not mounted. 11.C.7.v. Motorized vent damper. 11.C.7.w. Rollout safety switch. 11.C.7.x. Outdoor reset sensor kit. 11.C.7.x.1) Air Package: Diaphragm expansion tank, automatic fill valve and pressure reducing valve, and automatic float air vent. 11.C.8. Control Features: 11.C.8.a. Thermal targeting technology to conserve fuel. 11.C.8.b. LWCO function - Auto or manual reset. 11.C.8.c. Thermal pre-purge option. 11.C.8.d. LED display for operational info. 11.C.8.e. Circulator relay - 3 function options.</p><p>11.D. Basis of Design: Galaxy GXH series and manufactured by Slant/Fin. Natural draft, atmospheric preassembled cast-iron heat exchanger with built in air separator, vent damper, and tankless water heater. 11.D.1. Model GXH-105EDPT: 11.D.1.a. Input Rating: 150 MBH (43960.7 kW). 11.D.1.b. DOE Heating Capacity: 87000 BTUh (25.5 kW). 11.D.1.c. AHRI Net Output Rating: 76 MBH (22273.4 kW). 11.D.1.d. Square Feet Equivalent Direct Radiation: 500 sq ft (46.4 sq m). 11.D.1.e. Annual Fuel Utilization Efficiency (AFUE): 82.5 percent. 11.D.1.f. Nominal Vent Diameter: 5 in (127 mm). 11.D.2. Model GXH-125EDPT: 11.D.2.a. Input Rating: 126 MBH (36926.9 kW). 11.D.2.b. DOE Heating Capacity: 104000 BTUh (30.5 kW). 11.D.2.c. AHRI Net Output Rating: 90 MBH (26376.4 kW). 11.D.2.d. Square Feet Equivalent Direct Radiation: 600 sq ft (55.7 sq m). 11.D.2.e. Annual Fuel Utilization Efficiency (AFUE): 82.5 percent. 11.D.2.f. Nominal Vent Diameter: 6 in (152 mm). 11.D.3. Model GXH-150EDPT: 15510-11 11.D.3.a. Input Rating: 147 MBH (43081.4 kW). 11.D.3.b. DOE Heating Capacity: 122000 BTUh (35.7 kW). 11.D.3.c. AHRI Net Output Rating: 106 MBH (31065.5 kW). 11.D.3.d. Square Feet Equivalent Direct Radiation: 706 sq ft (65.6 sq m). 11.D.3.e. Annual Fuel Utilization Efficiency (AFUE): 82.5 percent. 11.D.3.f. Nominal Vent Diameter: 7 in (178 mm). 11.D.4. Model GXH-170EDPT: 11.D.4.a. Input Rating: 168 MBH (49235.9 kW). 11.D.4.b. DOE Heating Capacity: 140000 BTUh (41 kW). 11.D.4.c. AHRI Net Output Rating: 122 MBH (35754.7 kW). 11.D.4.d. Square Feet Equivalent Direct Radiation: 813 sq ft (75.5 sq m). 11.D.4.e. Annual Fuel Utilization Efficiency (AFUE): 82.5 percent. 11.D.4.f. Nominal Vent Diameter: 7 in (178 mm). 11.D.5. Model GXH-190EDPT: 11.D.5.a. Input Rating: 189 MBH (55390.4 kW). 11.D.5.b. DOE Heating Capacity: 158000 BTUh (46.3 kW). 11.D.5.c. AHRI Net Output Rating: 137 MBH (40150.7 kW). 11.D.5.d. Square Feet Equivalent Direct Radiation: 913 sq ft (84.8 sq m). 11.D.5.e. Annual Fuel Utilization Efficiency (AFUE): 82.5 percent. 11.D.5.f. Nominal Vent Diameter: 7 in (178 mm). 11.D.6. Boiler Characteristics: 11.D.6.a. Fuel type: Natural Gas. 11.D.6.b. Fuel Type: Propane. 11.D.6.c. Base: Insulated. 11.D.6.d. Base: Constructed and Insulated for placement on combustible flooring. 11.D.6.e. Pre-assembled insulated flush jacket 11.D.6.f. Flu collector. 11.D.6.g. Gas Burners: Stainless steel. 11.D.6.h. Orifices: Brass. 11.D.6.i. Manifold: Steel. 11.D.6.j. Redundant combination gas valve including manual shut-off, pressure regulator, 15510-12 pilot adjustment, and 100 percent shutoff. 11.D.6.k. Pilot ignition system: Intermittent spark. 11.D.6.l. Pressure, temperature, and altitude gauge 11.D.6.m. Pressure relief valve (ASME) 30 psi 11.D.6.n. 3-way combination control (hi-limit circulator relay, and lo-limit with differential). 11.D.6.o. Circulator: Taco 007 (GXH-105 thru GXH-190); X. 11.D.6.o.1) Circulator Flange: 1-1/4" (GXH-105 thru GXH-190) X. 11.D.6.o.2) Circulator manifold. 11.D.6.p. Circulator: Grundfos UPS 15-58F 1-1/4". 11.D.6.q. Circulator: B & G NRF 22 - 1-1/4". 11.D.6.r. Circulator: Taco 0010. 11.D.6.s. Circulator: Taco 110 1-1/4". 11.D.6.t. Circulator: B & G model 100 1-1/4". 11.D.6.u. Drain cock. 11.D.6.v. Tankless heater. 11.D.6.w. Blocked vent safety switch: Not mounted. 11.D.6.x. Motorized vent damper. 11.D.6.y. Rollout safety switch. 11.D.6.z. Outdoor reset sensor kit. 11.D.6.aa. Air Package: Diaphragm expansion tank, automatic fill valve and pressure reducing valve, and automatic float air vent. 11.D.7. Control Features: 11.D.7.a. Thermal targeting technology to conserve fuel. 11.D.7.b. LWCO function - Auto or manual reset. 11.D.7.c. Thermal pre-purge option. 11.D.7.d. LED display for operational info. 11.D.7.e. Circulator relay - 3 function options.</p><p>11.E. Basis of Design: Victory II VHS series and manufactured by Slant/Fin. Power vent, preassembled cast-iron heat exchanger with built in air eliminator. 11.E.1. Model VHS-30EP 11.E.1.a. Input Rating: 30 MBH (8.79 kW). 11.E.1.b. DOE Heating Capacity: 26000 BTUh (7.62 kW). 15510-13 11.E.1.c. AHRI Net Output Rating: 23 MBH (6.74 kW). 11.E.1.d. Square Feet Equivalent Direct Radiation: 150 sq ft ( sq m). 11.E.1.e. Annual Fuel Utilization Efficiency (AFUE): 84.5 percent. 11.E.1.f. Pressure Vent Diameter: 3 in (76 mm). 11.E.2. Model VHS-60EP 11.E.2.a. Input Rating: 60 MBH (17.58 kW). 11.E.2.b. DOE Heating Capacity: 50000 BTUh (14.65 kW). 11.E.2.c. AHRI Net Output Rating: 43 MBH (12.60 kW). 11.E.2.d. Square Feet Equivalent Direct Radiation: 287 sq ft ( sq m). 11.E.2.e. Annual Fuel Utilization Efficiency (AFUE): 83.4 percent. 11.E.2.f. Pressure Vent Diameter: 3 in (76 mm). 11.E.3. Model VHS-90EP 11.E.3.a. Input Rating: 90 MBH (26.38 kW). 11.E.3.b. DOE Heating Capacity: 75000 BTUh (21.98 kW). 11.E.3.c. AHRI Net Output Rating: 65 MBH (19.05 kW). 11.E.3.d. Square Feet Equivalent Direct Radiation: 433 sq ft ( sq m). 11.E.3.e. Annual Fuel Utilization Efficiency (AFUE): 82.8 percent. 11.E.3.f. Pressure Vent Diameter: 3 in (76 mm). 11.E.3.g. Chimney or Type "B" Vent: 5 in (127 mm). 11.E.4. Model VHS-120EP 11.E.4.a. Input Rating: 120 MBH (35.17 kW). 11.E.4.b. DOE Heating Capacity: 100000 BTUh (29.31 kW). 11.E.4.c. AHRI Net Output Rating: 87 MBH (25.50 kW). 11.E.4.d. Square Feet Equivalent Direct Radiation: 5580 sq ft ( sq m). 11.E.4.e. Annual Fuel Utilization Efficiency (AFUE): 82.2 percent. 11.E.4.f. Pressure Vent Diameter: 3 in (76 mm). 11.E.4.g. Chimney or Type "B" Vent: 5 in (127 mm). 11.E.5. Model VHS-150EP 11.E.5.a. Input Rating: 150 MBH (43.96 kW). 11.E.5.b. DOE Heating Capacity: 125000 BTUh (36.63 kW). 11.E.5.c. AHRI Net Output Rating: 109 MBH (31.94 kW). 15510-14 11.E.5.d. Square Feet Equivalent Direct Radiation: 727 sq ft ( sq m). 11.E.5.e. Annual Fuel Utilization Efficiency (AFUE): 82.1 percent. 11.E.5.f. Pressure Vent Diameter: 3 in (76 mm). 11.E.5.g. Chimney or Type "B" Vent: 5 in (127 mm). 11.E.6. Model VHS-180EP 11.E.6.a. Input Rating: 180 MBH (52.75 kW). 11.E.6.b. DOE Heating Capacity: 149000 BTUh (43.67 kW). 11.E.6.c. AHRI Net Output Rating: 130 MBH (38.10 kW). 11.E.6.d. Square Feet Equivalent Direct Radiation: 867 sq ft ( sq m). 11.E.6.e. Annual Fuel Utilization Efficiency (AFUE): 82.0 percent. 11.E.6.f. Pressure Vent Diameter: 3 in (76 mm). 11.E.6.g. Chimney or Type "B" Vent: 5 in (127 mm). 11.E.7. Boiler Characteristics: 11.E.7.a. Fuel type: Natural Gas. 11.E.7.b. Fuel Type: Propane. 11.E.7.c. Base: Insulated. 11.E.7.d. Base: Constructed and Insulated for placement on combustible flooring. 11.E.7.e. Pre-assembled insulated flush jacket. 11.E.7.f. Flu collector. 11.E.7.g. Gas Burners: Stainless steel. 11.E.7.h. Orifices: Brass. 11.E.7.i. Manifold: Steel. 11.E.7.j. Redundant combination gas valve including manual shut-off, pressure regulator, pilot adjustment, and 100 percent shutoff. 11.E.7.k. Pilot ignition system: Intermittent spark. 11.E.7.l. Pressure and temperature gauge. 11.E.7.m. Pressure relief valve (ASME) 30 psi. 11.E.7.n. Inducer assembly 11.E.7.o. Airflow proving switch. 11.E.7.p. Condensate Drain, Trap, and Vent Pipe Adapter: Built-in, stainless steel. 11.E.7.q. Circulator: Taco 007, 1-1/4 in (32 mm). 11.E.7.r. 15510-15 Circulator: Grundfos UPS 15-58F, 1-1/4 in (32 mm) 11.E.7.s. Circulator: B&G NRF 22, 1-1/4 in (32 mm) 11.E.7.t. Circulator: Taco 110, 1-1/4 in (32 mm). 11.E.7.u. Circulator: B&G 100, 1-1/4 in (32 mm) 11.E.7.v. Drain cock. 11.E.7.w. Rollout safety switch. 11.E.7.x. Outdoor reset sensor kit. 11.E.8. Venting System: 3 in (76 mm) diameter Saf-T EZ Seal venting system 11.E.9. Control Features: 11.E.9.a. Thermal targeting technology to conserve fuel. 11.E.9.b. LWCO function - Auto or manual reset. 11.E.9.c. Thermal pre-purge option. 11.E.9.d. LED display for operational info. 11.E.9.e. Circulator relay - 3 function options.</p><p>11.F. Basis of Design: Victory VSPH series and manufactured by Slant/Fin. Sealed combustion, direct vent, preassembled cast-iron heat exchanger with built in air eliminator.</p><p>1.12 PACKAGED, CAST-IRON. GAS-FIRED STEAM COMMERCIAL AND RESIDENTIAL BOILERS</p><p>12.A. Basis of Design: Galaxy GXH/GXHA series and manufactured by Slant/Fin. Natural draft, atmospheric preassembled cast-iron heat exchanger with built in air separator, vent damper, and tankless water heater.</p><p>1.13 PACKAGED, CAST-IRON. OIL-FIRED HOT WATER COMMERCIAL AND RESIDENTIAL BOILERS</p><p>13.A. Basis of Design: Intrepid TR Hot Water series and manufactured by Slant/Fin. Preassembled cast-iron heat exchanger.</p><p>13.B. Basis of Design: Intrepid TRDV Hot Water series and manufactured by Slant/Fin. Preassembled cast-iron heat exchanger.</p><p>13.C. Basis of Design: Eutectic EC-10 series and manufactured by Slant/Fin. Preassembled cast-iron heat exchanger.</p><p>13.D. Basis of Design: XL-2000, XL series and manufactured by Slant/Fin. Preassembled cast-iron heat exchanger.</p><p>1.14 PACKAGED, CAST-IRON. OIL-FIRED STEAM COMMERCIAL AND RESIDENTIAL BOILERS</p><p>14.A. 15510-16 Basis of Design: Intrepid TR Steam series and manufactured by Slant/Fin. Preassembled cast- iron heat exchanger.</p><p>1.15 PACKAGED, CAST-IRON. ELECTRIC HOT WATER COMMERCIAL AND RESIDENTIAL BOILERS</p><p>15.A. Basis of Design: Monitron EH series and manufactured by Slant/Fin. Preassembled cast-iron heat exchanger.</p><p>15.B. Basis of Design: Monitron Deluxe EH series and manufactured by Slant/Fin. Preassembled cast-iron heat exchanger.</p><p>1.16 PACKAGED STAINLESS STEEL WATER TUBE HIGH EFFICIENCY GAS-FIRED HOT WATER BOILERS</p><p>16.A. Basis of Design: Lynx, LX series and manufactured by Slant/Fin. Aluminum monobloc-iron heat exchanger.</p><p>16.B. Basis of Design: Lynx, LX Combi (CB) series and manufactured by Slant/Fin. Aluminum monobloc-iron heat exchanger.</p><p>16.C. Basis of Design: Jaguar, J390 series and manufactured by Slant/Fin. Aluminum monobloc-iron heat exchanger.</p><p>1.17 PACKAGED STAINLESS STEEL FIRE TUBE HIGH EFFICIENCY GAS-FIRED HOT WATER BOILERS</p><p>17.A. Basis of Design: Victory VSL series and manufactured by Slant/Fin. Preassembled stainless steel heat exchanger.</p><p>17.B. Basis of Design: Victory VSL II series and manufactured by Slant/Fin. Preassembled titanium, stainless steel heat exchanger.</p><p>17.C. Basis of Design: CHS, CHS series and manufactured by Slant/Fin. Preassembled stainless steel heat exchanger.</p><p>17.D. Basis of Design: CHS, CHS Multiple series and manufactured by Slant/Fin. Preassembled stainless steel heat exchanger.</p><p>1.18 KNOCKED-DOWN, CAST IRON, OIL FIRED, HOT WATER BOILERS</p><p>18.A. Basis of Design: Intrepid TR KD series and manufactured by Slant/Fin. Cast-iron heat exchanger.</p><p>18.B. Basis of Design: Eutectic EC-20 series and manufactured by Slant/Fin. Cast-iron heat exchanger. 18.B.1. EXECUTION</p><p>1.19 15510-17 EXAMINATION</p><p>19.A. Do not begin installation until substrates have been properly prepared.</p><p>19.B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.</p><p>1.20 PREPARATION</p><p>20.A. Clean surfaces thoroughly prior to installation.</p><p>20.B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.</p><p>1.21 INSTALLATION</p><p>21.A. Install in accordance with manufacturer's instructions. Test for proper operation.</p><p>1.22 PROTECTION</p><p>22.A. Protect installed products until completion of project.</p><p>22.B. Touch-up, repair or replace damaged products before Substantial Completion.</p><p>END OF SECTION</p><p>15510-18 </p>
Details
-
File Typepdf
-
Upload Time-
-
Content LanguagesEnglish
-
Upload UserAnonymous/Not logged-in
-
File Pages18 Page
-
File Size-