Arsine 1Ppm Sensor Specs 823-0212-21Rc.Pdf

Arsine 1Ppm Sensor Specs 823-0212-21Rc.Pdf

Document No. 365-2212-21 (Rev C) 3 Sensor Data Sheet Arsine (0 – 1.00 ppm) Part No. 823-0212-21 Minimum Indicated Concentration .............. 0.03 ppm Repeatability2 .............................................. ± 5% of Reading Accuracy1 .................................................... ± 10% of Reading Span Drift .................................................... < 5% change per 6 months (typical) 2 Response Time (Rise) .............................. T90: < 30 seconds 2 Recovery Time (Fall) ................................. T10: < 90 seconds Temperature Range ................................... -20° to 45°C (-4° to 113°F) Humidity Range (continuous)3 .................... 10–95 %RH, non-condensing Humidity Range (intermittent)3 .................... 0–99 %RH, non-condensing Pressure Range .......................................... Ambient atmospheric, ± 1 psi Expected Sensor Life .................................. 24 months from Shipping Date Recommended Calibration Flow Rate ........ 500 to 1000 cc/min Oxygen Requirement .................................. 1% by volume, minimum SensAlert 4-Channel Controller ................... Compatible 1 When unit is calibrated and serviced at recommended intervals. 2 Room Temperature, seasoned system. 3 Sensor is subject to minor moisture transients on sudden changes in moisture level. Note that transients are positive for increasing moisture and vice versa. Cross-Interferences* Gas Gas Exposure Sensor Output Carbon Monoxide 85 ppm None Chlorine 3 ppm -1 ppm Hydrogen Cyanide 18 ppm +1 ppm Hydrogen 3,100 ppm None Hydrogen Sulfide 1.7 ppm +1 ppm Sulfur Dioxide 3.3 ppm +1 ppm * Interference factors may differ from sensor to sensor, it is not advisable to calibrate with interferent gases. Sensidyne, LP • 1000 112th Circle N, Suite 100 • St. Petersburg, FL 33716 USA • 800-451-9444 • +1 727-530-3602 +1 727-539-0550 fax • web: www.sensidyne.com • e-mail: [email protected] Document No. 365-2212-21 (Rev C) Hydride Cross-Interferences* Gas Gas Exposure Sensor Output Arsine 1.0 ppm +1 ppm Diborane 1.1 ppm +1 ppm Germane 1.4 ppm +1 ppm Phosphine 0.6 ppm +1 ppm Silane 3.0 ppm +1 ppm * Interference factors may differ from sensor to sensor, it is not advisable to calibrate with interferent gases. Special Calibration Considerations: Arsine (PN° 823-0212-21) Zeroing The Sensor It is recommended that the sensors be zeroed in clean ambient air or bottled Zero Air. If zero air is used, a pre- zeroing exposure of 2 to 5 minutes is recommended to overcome possible moisture transients. Span Calibration It is recommended that this sensor be calibrated at 0.5 ppm AsH3 if possible. If accuracy is not an issue, PH3 gas may be used as a span gas with a 57% cross-interference factor. The use of Teflon™ tubing is recommended with this gas to prevent gas absorption into the tubing walls. Complete span calibration instructions are provided in the SensAlertPlus User Manual or SensAlert ASI User Manual. Test-on-Demand Cell Test-On-Demand cell available for this sensor: 821-0204-06 (Type S). The user should minimize the ToD cell intensity for a particular application to reduce the chance of the transmitter breaking out of ToD test mode while gas is still present. Otherwise, it could take 10 to 15 minutes for the gas levels to fall below alarm concentrations. Moisture Effects These sensors exhibit a minor positive moisture transient when exposed to a rapid increase in ambient moisture. The sensors underwent a minor negative transient when suddenly exposed to dry air (23ºC, 0%RH) after sitting in room air (23ºC, 55 – 60%RH). These transients took from 0.5 to 2 minutes to fall below zero suppression. Note that this gas will hydrolyze with moisture, reducing the apparent gas concentration. Sensidyne, LP • 1000 112th Circle N, Suite 100 • St. Petersburg, FL 33716 USA • 800-451-9444 • +1 727-530-3602 +1 727-539-0550 fax • web: www.sensidyne.com • e-mail: [email protected] .

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    2 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us