Standard Drawings & Oregon Standard Drawing Amendments Drainage Drawings

Standard Drawings & Oregon Standard Drawing Amendments Drainage Drawings

CITY of DALLAS Standard Drawings & Oregon Standard Drawing Amendments Drainage Drawings • RD300 (A) - Standard Trench Details • RD302 (A) - Trench Repair • RD303 - Trench Repair on New or Resurfaced Street • RD310 (A) - Sanitary and Storm Sewer Lateral Detail • RD335 (A) - Standard Storm Sewer Manhole • RD342 (A) - Shallow Manholes • RD350 (A) - Standard Drop Manhole Detail • RD356 (A) - Manhole Covers and Frames • RD360 (A) - Standard Manhole Adjustment in Streets • RD362 (A) - Standard Sanitary-Storm Cleanout Detail • RD366 (A) - Standard Catch Basin Detail (CG-2) • RD370 (A) - Field Inlet (Type D) • RD371 (A) - Standard Curb Inlet and Base Detail (CG-3) April 2016 Finish grade Surfacing-match Topsoil or existing material Top of as directed subgrade 12" min. Base material TABLE A "A" "B" "C" "D" CLSM (in) (in) (in) (in) Class E max.) Class C Class A directed) 4 10 4 8 Excavated nativematerial clean sand (1/4" 6 10 4 8 Class B, 1"-0 or 3/4"-0 crushed rock Trench backfill area material (3" max.)(As Class D, pit or bar-run 8 10 6 10 10 10 6 10 Tracer wire (See general 12 12 6 10 "D" note 4) 15 12 6 10 See Table A 18 16 6 12 21 16 6 12 Nom. Pipe zone 24 18 6 12 "B" "B" Pipe diameter 30 18 6 12 "A" see Table A 36 24 6 14 "C" Pipe bedding, 42 24 6 14 48 24 6 14 "C" Trench 54 24 6 14 foundation stabilization, 60 24 6 14 as required 24" min. 66 24 6 14 72 24 6 14 MULTIPLE INSTALLATIONS For pipes over 72" diameter, see general note 3. Dia. NOTES: DIAMETER MIN. SPACE BETWEEN PIPES 1. BACKFILL MATERIAL SHALL BE COMPACTED IN Up to 48" 24" 12" TO 18" LIFTS, DEPENDING ON COMPACTING TOOLS USED, AND COMPACTED TO A 95% 48" to 72" One half (1/2) dia. of pipe RELATIVE MAXIMUM DENSITY. 2. WHEEL ROLLING TRENCHES WITH BACKHOES MODIFICATIONS TO RD300: OR OTHER EQUIPMENT IS NOT CONSIDERED ACCEPTABLE COMPACTING WORKMANSHIP. 1. DETAILS, DIMENSIONS AND SPECIFICATIONS SHOWN HERE 3. SURFACING OF PAVED AREAS SHALL COMPLY AMEND THE DETAILS SHOWN ON OREGON STANDARD 5/5/2016 12:00 PM WITH STREET CUT STD. DRG. RD302. DRAWING RD300. 4. FOR PIPE INSTALLATION IN EMBANKMENT 2. FOR ADDITIONAL DETAILS AND DETAILS NOT SHOWN HERE, AREAS WHERE THE TRENCH METHOD WILL NOT SEE OREGON STANDARD DRAWING RD300. BE USED AND THE PIPE IS ≥ 36" DIAMETER, INCREASE DIMENSION "B" TO NOMINAL PIPE DIAMETER. 5. PIPES OVER 72" DIAMETER ARE STRUCTURES, AND ARE NOT APPLICABLE TO THIS DRAWING. 6. SEE STD. DRG. RD336 FOR TRACER WIRE DETAILS (WHEN REQUIRED). CITY OF DALLAS OREGON DRAWING NO. STANDARD DRAWING AMENDMENT RD300 (A) 0 Adoption of Standard Drawings CTG 4/11/2016 STANDARD TRENCH DETAILS NO. REVISIONS BY DATE CDO ROADWAY 300 SERIES - DRAINAGE.dwg Half Section Half Section Rigid Pavement w/ AC Surface P.C.C. Pavement Match Exist. Pvmt. Match Existing AC - Thickness or 6" Min. Saw Vertically (See Note 3) 4" Min. Class 3500 P.S.I. P.C.C. Existing P.C.C. Pavement Existing AC Existing P.C.C. Pavement Existing Base Existing Base Compacted Backfill 12" 12" (See Detail RD 300(A) ) Min. Min. Trench Width TYPICAL PATCH FOR RIGID PAVEMENT Tack Coat all Cut Edges, and Seal Surface Over Saw Vertically (See Note 3) Joints with Tack and Sand New AC Existing AC (AC Patch Only) Patch 4" Min. Existing Base Existing Base 12" 12" Min. Min. Compacted Backfill Trench Width (See Detail RD 300(A) ) TYPICAL PATCH FOR FLEXIBLE PAVEMENT Notes: 1. SAWCUT EXISTING ASPHALT A MINIMUM OF 12" TO UNDISTURBED PAVEMENT. 2. SAWCUTS WILL BE MADE PARALLEL TO TRENCH. 3. CUTS IN AC PAVEMENT SHALL BE MADE W/ A CUTTING WHEEL, CONCRETE SAW OR OTHER APPROVED METHOD. CUTS IN P.C.C. PAVEMENT SHALL BE DONE W/ A CONCRETE SAW. INTERMITTENT PUNCHING WITH A POINTED JACK HAMMER SHALL NOT BE PERMITTED. 4. FINAL ASPHALT THICKNESS SHALL BE OF 4", OR AS REQUIRED TO MATCH EXISTING MODIFICATIONS TO RD302: THICKNESS, WHICHEVER IS GREATER. 5. ASPHALT SHALL BE PLACED IN A MINIMUM OF 1. DETAILS, DIMENSIONS AND SPECIFICATIONS SHOWN HERE TWO LIFTS. CLASS "C" MIX SHALL BE THE AMEND THE DETAILS SHOWN ON OREGON STANDARD 5/5/2016 12:00 PM WEARING COURSE. DRAWING RD302. 6. TRENCH SURFACE SHALL BE MAINTAINED 2. FOR ADDITIONAL DETAILS AND DETAILS NOT SHOWN HERE, DAILY, UNTIL PERMANENT SURFACE REPAIR SEE OREGON STANDARD DRAWING RD302. IS IN PLACE. ON ASPHALT, COLD PATCH MIX SHALL BE USED UNTIL TRENCH IS RESURFACED. 7. IF STREET IS NEW, OR HAS BEEN RESURFACED, USE DETAIL RD303(A). CITY OF DALLAS OREGON DRAWING NO. STANDARD DRAWING AMENDMENT RD302 (A) 0 Adoption of Standard Drawings CTG 4/11/2016 TRENCH REPAIR NO. REVISIONS BY DATE CDO ROADWAY 300 SERIES - DRAINAGE.dwg Cold Plane AC 2" Min. D D Min. Min. 12" Min. Width of Trench 12" Min. New AC Patch - 4" Min. D Class E - CLSM Backfill **Tack Coat all Cut Edges, and Seal Surface Over Joints with Tack and Sand (AC Patch Only) NOTES: 1. SAWCUT EXISTING ASPHALT A MINIMUM OF 12" TO UNDISTURBED PAVEMENT. 2. SAWCUTS WILL BE MADE PARALLEL TO TRENCH. 3. FINAL ASPHALT THICKNESS SHALL BE OF 4", OR AS REQUIRED TO MATCH EXISTING THICKNESS, 5/5/2016 12:00 PM WHICHEVER IS GREATER. 4. ASPHALT SHALL BE PLACED IN A MINIMUM OF TWO LIFTS. CLASS "C" MIX SHALL BE THE WEARING COURSE. 5. TRENCH SURFACE SHALL BE MAINTAINED DAILY, UNTIL PERMANENT SURFACE REPAIR IS IN PLACE. ON ASPHALT, COLD PATCH MIX SHALL BE USED UNTIL TRENCH IS RESURFACED. 6. COLD PLANE AC MINIMUM OF 2" THE TOTAL WIDTH OF "D". 7. CITY ENGINEER TO DETERMINE IF STREET IS NEW OR RECENTLY RESURFACED. CITY OF DALLAS OREGON DRAWING NO. STANDARD DRAWING RD303 0 Adoption of Standard Drawings CTG 4/11/2016 TRENCH REPAIR ON NEW OR RESURFACED NO. REVISIONS BY DATE STREET CDO ROADWAY 300 SERIES - DRAINAGE.dwg End of 2x4 Lateral Marker Shall be Labeled as Follows: S.S. ROW / Property S.S. or S.D. - Sanitary or Storm Lateral L=X' Line D=X' L=X' - Length of Lateral From Main in 'X' Feet 05 D=X' - Depth of the End of Lateral in 'X' Feet (Run Tracer Wire to Top of Marker, Where Applies) 08 -- Legend Sidewalk 01. Wye or Tee ASTM D-3034 PVC Fittings, or ASTM C-14, C-76 Concrete Manufactured Fittings. Street Surface 02. 45° or Smaller Bend Required. Insert Into Wye Or Tee. 03. Sanitary Laterals are to be ASTM D-3034 PVC GREEN Pipe Only. Storm Laterals are to be ASTM D-3034 PVC WHITE Pipe Only. Laterals shall have nominal inside diameters of 4 and 6 inches and use long radius bends at all changes in direction. 04. Mechanical Rubber or Any Other Rubber Sealed, Water Tight Plug. 07 Class "A" Backfill 05. A Full Length 2x4 Marker of Which the Top 2 Feet Will be Exposed and Painted Green For SANITARY SEWER and 4' MIN. White for STORM SEWER, Marking the End of the Lateral. The Lateral Will Terminate Either at the Property Line or the 09 Class "B or D" Backfill Lot Side of the PUE (Public Utility Easement), Whichever is Greater. 02 06. Bedding and Pipe Zone: 3/4" Minus Compacted Crushed Rock, Giving the Pipe and Any Fittings a Uniform Firm Bed 01 03 to Lay on. Pipe Zone Includes a Minimum of 6" of Rock All Around the Pipe. 07. Backfill Requirements: Class "B or D" Backfill: Under Pavement and Graveled Street, Driveways and Parking Areas, as Well as Existing Sidewalks and Shoulders. Class "A" Backfill: Under Landscaped Areas, Lawns, Fields and Any Other 04 Area Where Class "B or D" is Not Required. Restore Top 12" to Previous Conditions or Better. Tracer Wire 06 08. Install cleanout, see RD362(A). 09. No Profinding Taps Allowed. NOTES: 1. TAPPING OF EXISTING MAINS SHALL BE DONE BY CITY OF DALLAS PERSONNEL. INVERT AT END OF FITTING IS NOT TO BE LOWER THAN HORIZONTAL CENTER LINE OF MAIN. 2. MINIMUM GRADE FOR LATERALS WILL BE 2% OR 1/4" PER FOOT AND MUST BE WATER TIGHT. 3. LATERAL WILL DROP INTO MAIN AT TOP HALF OF THE MAIN. ROTATE WYE OR TEE AS NEEDED. MODIFICATIONS TO RD310: 4. TRACER WIRE IS REQUIRED ON ALL LATERALS. 1. DETAILS, DIMENSIONS AND SPECIFICATIONS SHOWN 5. SERVICE CONNECTIONS ARE ALLOWED TO THE SEWER SYSTEM AT A MANHOLE AS APPROVED HERE AMEND THE DETAILS SHOWN ON OREGON 5/5/2016 12:00 PM BY THE CITY ENGINEER. STANDARD DRAWING RD310. 6. WHERE TEES OR WYES FOR CONNECTION ARE ABSENT OR UNUSABLE, CONNECTION OF 2. FOR ADDITIONAL DETAILS AND DETAILS NOT SHOWN SERVICE LINES SHALL BE MADE WITH AN APPROVED TAP SUCH AS SCALTITE SADDLE, HERE, SEE OREGON STANDARD DRAWING RD310. FOWLER TAP, FOWLER TEE, TAP-TITE TEE, OR EQUAL COMMERCIAL TAP. CITY OF DALLAS OREGON STANDARD DRAWING AMENDMENT SANITARY AND STORM SEWER LATERAL DETAIL DRAWING NO. RD310 0 Adoption of Standard Drawings CTG 4/11/2016 (A) REVISIONS BY DATE NO. CDO ROADWAY 300 SERIES - DRAINAGE.dwg Street Surface Precast Concrete Riser Rings as Required. Standard Manhole Frame and Cover. Grouted in Place. Set w/ Mortar to Match Finish Grade. Rings Are Not to Exceed 1' Grout Tracer Wire Eccentric Manhole Top. 24" (See Detail "A" on Std. Drg. RD336). (Must Conform to ASTM C-478) 24" Max No Steps Polyurethane Sealant to Fill Outside of Manhole 36" Crack at Joint Gasket or Butyl Compound Mastic Sealer Rubber Wrap Use Only Manufactured Rubber Construct Channel and Shelf Manhole Boots for Sanitary Sewer In One Operation.

View Full Text

Details

  • File Type
    pdf
  • Upload Time
    -
  • Content Languages
    English
  • Upload User
    Anonymous/Not logged-in
  • File Pages
    14 Page
  • File Size
    -

Download

Channel Download Status
Express Download Enable

Copyright

We respect the copyrights and intellectual property rights of all users. All uploaded documents are either original works of the uploader or authorized works of the rightful owners.

  • Not to be reproduced or distributed without explicit permission.
  • Not used for commercial purposes outside of approved use cases.
  • Not used to infringe on the rights of the original creators.
  • If you believe any content infringes your copyright, please contact us immediately.

Support

For help with questions, suggestions, or problems, please contact us